End-tidal carbon dioxide levels during resuscitation and carbon dioxide levels in the immediate neonatal period and intraventricular haemorrhage

被引:13
|
作者
Tamura, Kentaro [1 ,2 ]
Williams, Emma E. [1 ]
Dassios, Theodore [1 ,3 ]
Pahuja, Anoop [1 ]
Hunt, Katie A. [1 ]
Murthy, Vadivelam [1 ]
Bhat, Prashanth [1 ]
Bhat, Ravindra [3 ]
Milner, Anthony [1 ]
Greenough, Anne [1 ,4 ,5 ,6 ]
机构
[1] Kings Coll London, Women & Childrens Hlth, Sch Life Course Sci, Fac Life Sci & Med, London, England
[2] Toyama Univ Hosp, Maternal & Perinatal Ctr, Div Neonatol, Toyama, Japan
[3] Kings Coll Hosp NHS Fdn Trust, Neonatal Intens Care Ctr, London, England
[4] Kings Coll London, Asthma UK Ctr Allerg Mech Asthma, London, England
[5] Guys & St Thomas NHS Fdn Trust, NIHR Biomed Res Ctr, London, England
[6] Kings Coll London, London, England
关键词
Carbon dioxide; End-tidal carbon dioxide; Intraventricular haemorrhage; Prematurity; Resuscitation; MASK VENTILATION; INFANTS; FLUCTUATIONS; OXYGENATION; PRESSURE;
D O I
10.1007/s00431-019-03543-0
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Abnormal levels of end-tidal carbon dioxide (EtCO2) during resuscitation in the delivery suite are associated with intraventricular haemorrhage (IVH) development. Our aim was to determine whether carbon dioxide (CO2) levels in the first 3 days after birth reflected abnormal EtCO2 levels in the delivery suite, and hence, a prolonged rather than an early insult resulted in IVH. In addition, we determined if greater EtCO(2)level fluctuations during resuscitation occurred in infants who developed IVH. EtCO2 levels during delivery suite resuscitation and CO2 levels on the neonatal unit were evaluated in 58 infants (median gestational age 27.3 weeks). Delta EtCO2 was the difference between the highest and lowest level of EtCO2. Thirteen infants developed a grade 3-4 IVH (severe group). There were no significant differences in CO2 levels between those who did and did not develop an IVH (or severe IVH) on the NICU. The delta EtCO2 during resuscitation differed between infants with any IVH (6.2 (5.4-7.5) kPa) or no IVH (3.8 (2.7-4.3) kPA) (p < 0.001) after adjusting for differences in gestational age. Delta EtCO2 levels gave an area under the ROC curve of 0.940 for prediction of IVH. Conclusion: The results emphasize the importance of monitoring EtCO2 levels in the delivery suite.What is Known:center dot Abnormal levels of carbon dioxide (CO2) in the first few days after birth and abnormal end-tidal CO(2)levels (EtCO2) levels during resuscitation are associated in preterm infants with the risk of developing intraventricular haemorrhage (IVH).What is New:center dot There were no significant differences in NICU CO(2)levels between those who developed an IVH or no IVH.center dot There was a poor correlation between delivery suite ETCO(2)levels and NICU CO(2)levels.center dot Large fluctuations in EtCO(2)during resuscitation in the delivery suite were highly predictive of IVH development in preterm infants.
引用
收藏
页码:555 / 559
页数:5
相关论文
共 50 条
  • [21] Contribution of chest compressions to end-tidal carbon dioxide levels generated during out-of- hospital cardiopulmonary resuscitation
    Gutierrez, Jose Julio
    Sandoval, Camilo Leonardo
    Leturiondo, Mikel
    Russell, James Knox
    Redondo, Koldo
    Daya, Mohamud Ramzan
    de Gauna, Sofia Ruiz
    RESUSCITATION, 2022, 179 : 225 - 232
  • [22] Neonatal end-tidal carbon dioxide detection and waveform capnography
    Fawke, J.
    Wyllie, J.
    ANAESTHESIA, 2019, 74 (01) : 114 - 115
  • [23] Effect of End-Tidal Carbon Dioxide Measurement on Resuscitation Efficiency and Termination of Resuscitation
    Ozturk, Faruk
    Parlak, Ismet
    Yolcu, Sadiye
    Tomruk, Onder
    Erdur, Bulent
    Kilicaslan, Rifat
    Miran, Ali Savas
    Akay, Serhat
    TURKISH JOURNAL OF EMERGENCY MEDICINE, 2014, 14 (01): : 25 - 31
  • [24] A method for monitoring end-tidal carbon dioxide levels for patients breathing spontaneously
    Fenlon, S
    Vincent, C
    ANAESTHESIA, 2000, 55 (02) : 189 - 189
  • [25] In reply: Low levels of end-tidal carbon dioxide during general anesthesia and postoperative mortality
    Dong, Li
    Mizota, Toshiyuki
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2022, 69 (03): : 391 - 392
  • [26] In reply: Low levels of end-tidal carbon dioxide during general anesthesia and postoperative mortality
    Li Dong
    Toshiyuki Mizota
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2022, 69 : 391 - 392
  • [27] Comparison of end-tidal carbon dioxide levels with cardiopulmonary resuscitation success presented to emergency department with cardiopulmonary arrest
    Akinci, Emine
    Ramadan, Hayri
    Yuzbasioglu, Yucel
    Coskun, Figen
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2014, 30 (01) : 16 - 21
  • [28] Continuous End-Tidal Carbon Dioxide Monitoring during Resuscitation of Asphyxiated Term Lambs
    Chandrasekharan, Praveen Kumar
    Rawat, Munmun
    Nair, Jayasree
    Gugino, Sylvia F.
    Koenigsknecht, Carmon
    Swartz, Daniel D.
    Vali, Payam
    Mathew, Bobby
    Lakshminrusimha, Satyan
    NEONATOLOGY, 2016, 109 (04) : 265 - 273
  • [29] MEASUREMENT OF END-TIDAL CARBON-DIOXIDE CONCENTRATION DURING CARDIOPULMONARY-RESUSCITATION
    STEEDMAN, DJ
    ROBERTSON, CE
    ARCHIVES OF EMERGENCY MEDICINE, 1990, 7 (03): : 129 - 134
  • [30] PREDICTIVE VALUE OF END-TIDAL CARBON-DIOXIDE DURING CARDIOPULMONARY-RESUSCITATION
    NIELSEN, M
    FITCHET, A
    SAUNDERS, D
    CRITICAL CARE MEDICINE, 1991, 19 (06) : 841 - 841