Study of Electric Transmission Line Deep Foundation Design

被引:0
|
作者
Kandaris, P. M. [1 ]
Davidow, S. [2 ]
机构
[1] DiGioia Gray & Asso LLC, 570 Beatty Rd, Monroeville, PA 15146 USA
[2] Crux Subsurface Inc, Spokane Valley, WA 99027 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical system transmission line structures are typically supported by deep foundations such as concrete drilled shafts, driven piles, micropiles, and helical piles. Although a number of industry guidelines describe the fundamental design principles and construction/installation procedures of these foundation types, there is no comprehensive electrical system guideline, which relates all the elements needed to properly characterize loads imposed by electrical structures and extreme environmental conditions on foundations. There is a lack of guidance on relating electrical system loads developed from various industry codes to foundations governed by traditional civil engineering design standards. A task force assembled by the Deep Foundation Institute has conducted a survey of utility design professional to assess the state of the practice for transmission structure foundation design. This survey, in conjunction with a thorough literature review, will be used to develop a guideline design document with recommendations for uniform analysis and design of electrical system deep foundations. This paper provides a summary of task force efforts to date and the initial industry survey results. Included are discussions of existing design and code documents as they relate to electric transmission line foundations, and elements needed in a guide document to improve the efficiency and reliability of electrical transmission line foundation design.
引用
收藏
页码:577 / 587
页数:11
相关论文
共 50 条
  • [41] Resident perceptions of a nearby electric transmission line
    Priestley, T
    Evans, GW
    JOURNAL OF ENVIRONMENTAL PSYCHOLOGY, 1996, 16 (01) : 65 - 74
  • [42] Design of Retaining and Protecting for a Deep Foundation Excavation
    Jin, Huiwu
    ADVANCED CONSTRUCTION TECHNOLOGIES, 2014, 919-921 : 1416 - 1420
  • [44] Experimental study on excavated foundation of transmission line gravelly soils in gobi area of Northwest China
    Lu, Xian-Long
    Zheng, Wei-Feng
    Cheng, Yong-Feng
    Tong, Rui-Ming
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2009, 31 (11): : 1779 - 1783
  • [45] Pankow Foundation awards grant to study electric vehicle impact on parking structure design
    Burgess, K. Michelle
    PCI JOURNAL, 2024, 69 (04):
  • [46] Foundation evaluation of river-crossed tower in a transmission line
    Zhou, YQ
    Yang, YK
    EIGHTH INTERNATIONAL CONGRESS INTERNATIONAL ASSOCIATION FOR ENGINEERING GEOLOGY AND THE ENVIRONMENT, PROCEEDINGS, VOLS 1-5, 1998, : 3297 - 3302
  • [47] Design of a microstrip transmission line filter with transmission zeros
    Zhu, Y.-Z. (haiyihaiyi@hotmail.com), 1600, Beijing University of Posts and Telecommunications (35):
  • [48] Study on Type Design of Multi-circuit Transmission Line Tower
    Wang, Yanhai
    Meng, Suimin
    Tang, Bo
    ADVANCES IN INDUSTRIAL AND CIVIL ENGINEERING, PTS 1-4, 2012, 594-597 : 900 - 903
  • [49] Discussion of Concrete Pier Foundation Design for Transmission Structures
    Shi, Haijian
    Pizzo, Drew
    GEOTECHNICAL FRONTIERS 2017: FOUNDATIONS, 2017, (279): : 345 - 354
  • [50] The assessment of compensation for the electric transmission line easement through a study of land market in Apulia
    Sardaro, Ruggiero
    Bozzo, Francesco
    Fucilli, Vincenzo
    AESTIMUM, 2018, 73 : 219 - 237