Optical Waveguide Biosensor Based on Cascaded Mach-Zehnder Interferometer and Ring Resonator with Vernier Effect

被引:3
|
作者
Jiang, Xianxin [1 ]
Tang, Longhua [1 ]
Song, Jinyan [1 ]
Li, Mingyu [1 ]
He, Jian-Jun [1 ]
机构
[1] Zhejiang Univ, Ctr Integrated Optoelect, Dept Opt Engn, State Key Lab Modern Opt Instrumentat, Hangzhou 310027, Zhejiang, Peoples R China
来源
FRONTIERS IN BIOLOGICAL DETECTION: FROM NANOSENSORS TO SYSTEMS VII | 2015年 / 9310卷
关键词
Optical waveguide sensor; microring; Mach-Zehnder interferometer; Vernier effect; SILICON; SENSORS;
D O I
10.1117/12.2077943
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Optical waveguide biosensors based on silicon-on-insulator (SOI) have been extensively investigated owing to its various advantages and many potential applications. In this article, we demonstrate a novel highly sensitive biosensor based on cascaded Mach-Zehnder interferometer (MZI) and ring resonator with the Vernier effect using wavelength interrogation. The experimental results show that the sensitivity reached 1,960 nm/RIU and 19,100 nm/RIU for sensors based on MZI alone and cascaded MZI-ring with Vernier effect, respectively. A biosensing application was also demonstrated by monitoring the interaction between goat and antigoat immunoglobulin G (IgG) pairs. This integrated high sensitivity biosensor has great potential for medical diagnostic applications.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Simulation of a refractive index sensor based on the Vernier effect and a cascaded PANDA and Mach–Zehnder interferometer
    Bahram Azizi
    Mohammad Amir Ghasemi Shabankareh
    Ali Farmani
    Journal of Computational Electronics, 2021, 20 : 1599 - 1610
  • [42] Optical biosensor microsystems based on the integration of highly sensitive Mach-Zehnder interferometer devices
    Sepulveda, B.
    Sanchez del Rio, J.
    Moreno, M.
    Blanco, F. J.
    Mayora, K.
    Dominguez, C.
    Lechuga, L. M.
    JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2006, 8 (07): : S561 - S566
  • [43] Wide Range Si3N4 Optical Sensor Using Cascaded Mach-Zehnder Interferometer Coupled Ring Resonator
    Hu Y.
    Applied Mathematics and Nonlinear Sciences, 2024, 9 (01)
  • [44] Nested fiber ring resonator enhanced Mach-Zehnder interferometer for temperature sensing
    Yu, Changqiu
    Zhang, Yundong
    Zhang, Xuenan
    Wang, Kaiyang
    Yao, Chengbao
    Yuan, Ping
    Guan, Yudong
    APPLIED OPTICS, 2012, 51 (36) : 8873 - 8876
  • [45] Integrated optical Mach-Zehnder biosensor
    Luff, BJ
    Wilkinson, JS
    Piehler, J
    Hollenbach, U
    Ingenhoff, J
    Fabricius, N
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 1998, 16 (04) : 583 - 592
  • [46] Mach-Zehnder interferometer assisted ring resonator configuration for refractive index sensing
    Yadav, Mukesh
    Aksnes, Astrid
    2021 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE & EUROPEAN QUANTUM ELECTRONICS CONFERENCE (CLEO/EUROPE-EQEC), 2021,
  • [47] Silicon-on-Insulator Optical Waveguide Pressure Sensor Based on Mach-Zehnder Interferometer
    Li, Chen
    Zhang, Chi
    Yang, Lijun
    Guo, Fangtong
    MICROMACHINES, 2022, 13 (08)
  • [48] Optical Waveguide Electric Field Sensor Based on Dual Parallel Mach-Zehnder Interferometer
    Zhang, Jiahong
    Li, Yingna
    Jiang, Chao
    Zhao, Zhengang
    IEEE SENSORS JOURNAL, 2021, 21 (18) : 20099 - 20106
  • [49] Ultrasensitive measurement of gas refractive index based on cascaded Mach-Zehnder interferometers and Vernier effect
    Li, Jun
    Cheng, Hongwei
    Lin, Hongfeng
    Li, Hao
    Zhou, Ai
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (09)
  • [50] Pseudo noise sequence generator based on cascaded Mach-Zehnder interferometer
    Kumar R.
    Journal of Optical Communications, 45