Regular radon activity concentration and effective dose measurements inside the great pyramid with passive nuclear track detectors

被引:3
|
作者
Hafez, AF [1 ]
Bishara, AA
Kotb, MA
Hussein, AS
机构
[1] Univ Alexandria, Fac Sci, Dept Phys, Alexandria 21511, Egypt
[2] Univ Alexandria, Med Res Inst, Dept Biophys, Alexandria 21511, Egypt
来源
HEALTH PHYSICS | 2003年 / 85卷 / 02期
关键词
radon; effective dose; detector; alpha-track; environmental assessment;
D O I
10.1097/00004032-200308000-00010
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Radon activity concentrations and equilibrium factors inside the great pyramid of "Cheops" were measured with passive nuclear track detectors. The variation of these concentrations in location was investigated. Seasonal variation of radon activity concentrations with winter maximum and summer minimum were observed inside the pyramid. The 1-y average radon activity concentration ranged from a minimum of 20 to a maximum of 170 Bq m(-3). Results show that the yearly average equilibrium factor between radon and its progeny was assessed as 0.16 and 0.36 inside the pyramid and near entrance, respectively. Moreover, the estimated annual effective dose was 0.05 mSv to tour guides and varied from 0.19 to 0.36 mSv for the pyramid guards; for visitors the average effective dose was 0.15 muSv per visit. These are lower than the 3-10 mSv y(-1) dose limit recommend by ICRP 65.
引用
收藏
页码:210 / 215
页数:6
相关论文
共 50 条
  • [31] Long-term measurements of radon progeny concentrations with solid-state nuclear track detectors
    Yu, KN
    Nikezic, D
    Ng, FMF
    Leung, JKC
    RADIATION MEASUREMENTS, 2005, 40 (2-6) : 560 - 568
  • [32] Experimental evaluation of combined ageing and fading effects on annual radon concentration measurement based on nuclear track detectors
    Caprio, M.
    Ampollini, M.
    Antignani, S.
    Carpentieri, C.
    Di Carlo, C.
    Maiorana, A.
    Bochicchio, F.
    RADIATION MEASUREMENTS, 2025, 181
  • [33] Radium concentration and radon exhalation measurements using LR-115 type II plastic track detectors
    Azam, A
    Naqvi, AH
    Srivastava, DS
    NUCLEAR GEOPHYSICS, 1995, 9 (06): : 653 - 657
  • [34] Indoor radon measurements in dwellings of Kulu area, Himachal Pradesh, using solid state nuclear track detectors
    Singh, S
    Malhotra, R
    Kumar, J
    Singh, L
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 505 - 508
  • [35] Indoor radon activity concentration measurements in the great historical museums of University of Naples, Italy
    Quarto, Maria
    Pugliese, Mariagabriella
    Loffredo, Filomena
    La Verde, Giuseppe
    Roca, Vincenzo
    RADIATION PROTECTION DOSIMETRY, 2016, 168 (01) : 116 - 123
  • [36] Radon measurements by nuclear track detectors in dwellings in Oke-Ogun area, South-Western, Nigeria
    Obed, R. I.
    Ademola, A. K.
    Ogundare, F. O.
    RADIATION PROTECTION DOSIMETRY, 2012, 148 (04) : 475 - 481
  • [37] INDOOR RADON ACTIVITY CONCENTRATION AND EFFECTIVE DOSE RATES AT SCHOOLS AND THERMAL SPAS OF ILGIN
    Erdogan, Mehmet
    Abaka, Murat
    Manisa, Kaan
    Bircan, Hasan
    Kus, Coskun
    Zedef, Veysel
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2020, 35 (04): : 339 - 346
  • [38] Activity concentration and annual effective dose assessments of radon in SCCs with different mineral additives
    Bulut, H. Alperen
    Sahin, Remzi
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 364
  • [39] Study of environmental radon exhalation, radium and effective dose in Dilli-Jeypore coalfield, India using LR-115 (II) nuclear track detectors
    Barooah, D.
    Barman, S.
    Phukan, S.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2013, 51 (10) : 690 - 695
  • [40] Indoor radon concentrations and annual effective dose rates for spring and summer seasons by using CR-39 nuclear track detectors in dwellings in Manisa, Turkey
    Sermin Çam-Kaynar
    Yasemin Parlak
    Arabian Journal of Geosciences, 2022, 15 (17)