Regular radon activity concentration and effective dose measurements inside the great pyramid with passive nuclear track detectors

被引:3
|
作者
Hafez, AF [1 ]
Bishara, AA
Kotb, MA
Hussein, AS
机构
[1] Univ Alexandria, Fac Sci, Dept Phys, Alexandria 21511, Egypt
[2] Univ Alexandria, Med Res Inst, Dept Biophys, Alexandria 21511, Egypt
来源
HEALTH PHYSICS | 2003年 / 85卷 / 02期
关键词
radon; effective dose; detector; alpha-track; environmental assessment;
D O I
10.1097/00004032-200308000-00010
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Radon activity concentrations and equilibrium factors inside the great pyramid of "Cheops" were measured with passive nuclear track detectors. The variation of these concentrations in location was investigated. Seasonal variation of radon activity concentrations with winter maximum and summer minimum were observed inside the pyramid. The 1-y average radon activity concentration ranged from a minimum of 20 to a maximum of 170 Bq m(-3). Results show that the yearly average equilibrium factor between radon and its progeny was assessed as 0.16 and 0.36 inside the pyramid and near entrance, respectively. Moreover, the estimated annual effective dose was 0.05 mSv to tour guides and varied from 0.19 to 0.36 mSv for the pyramid guards; for visitors the average effective dose was 0.15 muSv per visit. These are lower than the 3-10 mSv y(-1) dose limit recommend by ICRP 65.
引用
收藏
页码:210 / 215
页数:6
相关论文
共 50 条
  • [1] APPLICATION OF NUCLEAR TRACK DETECTORS FOR RADON RELATED MEASUREMENTS
    ABUJARAD, FA
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1988, 15 (1-4): : 525 - 534
  • [2] RADON AND THORON MEASUREMENTS USING NUCLEAR TRACK DETECTORS
    MORSY, AA
    DURRANI, SA
    GEOPHYSICAL JOURNAL OF THE ROYAL ASTRONOMICAL SOCIETY, 1985, 81 (01): : 332 - 332
  • [3] A preliminary study of the radon and thoron concentration distribution inside a cellar using nuclear track detectors (NTDs)
    Instituto de Física, Universidad Nacional Autónoma de México , Apartado Postal 20-364, México, DF
    04510, Mexico
    Solid State Phenomena, (127-133):
  • [4] INDOOR RADON CONCENTRATION MEASUREMENTS IN SOME SPANISH HOUSES AND DWELLINGS WITH PLASTIC NUCLEAR TRACK DETECTORS
    BAIXERAS, C
    GARCIA, I
    FERNANDEZ, F
    DOMINGO, C
    VIDALQUADRAS, A
    PIESCH, E
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 279 - 282
  • [5] Influence of atmospheric pressure on radon measurements with nuclear track detectors
    Schaible, A
    Smyczynski, T
    Herzog, W
    Hingmann, H
    Rox, A
    RADIOACTIVITY IN HUMANS AND THE ENVIRONMENT, 1998, : 411 - 416
  • [6] CALIBRATION OF THE POLITRACK® SYSTEM BASED ON CR39 SOLID-STATE NUCLEAR TRACK DETECTORS FOR PASSIVE INDOOR RADON CONCENTRATION MEASUREMENTS
    Kropat, G.
    Baechler, S.
    Bailat, C.
    Barazza, F.
    Bochud, F.
    Damet, J.
    Meyer, N.
    Gruson, M. Palacios
    Butterweck, G.
    RADIATION PROTECTION DOSIMETRY, 2015, 167 (1-3) : 302 - 305
  • [7] SOME IMPORTANT CONSIDERATIONS IN THE USE OF SOLID-STATE NUCLEAR TRACK DETECTORS FOR RADON GAS CONCENTRATION MEASUREMENTS
    AKBER, RA
    KHAN, HA
    AHMAD, I
    JAMIL, K
    NUCLEAR INSTRUMENTS & METHODS, 1980, 173 (01): : 183 - 189
  • [8] Direct measurements of radon activity in water from various natural sources using nuclear track detectors
    Marques, AL
    dos Santos, W
    Geraldo, LP
    APPLIED RADIATION AND ISOTOPES, 2004, 60 (06) : 801 - 804
  • [9] Comparative measurements of soil gas radon concentration using thermoluminescent and track detectors
    Turek, K
    Gelev, M
    Dimov, I
    RADIATION MEASUREMENTS, 2004, 38 (4-6) : 843 - 846
  • [10] SOLID-STATE NUCLEAR TRACK DETECTORS IN RADON MEASUREMENTS INDOORS AND IN THE SOIL
    JONSSON, G
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 335 - 338