THE EFFECT OF DENTIN PRETREATMENT ON THE MICROTENSILE BOND STRENGTH OF SELF-ADHESIVE RESIN CEMENTS

被引:59
|
作者
Pavan, Sabrina [1 ]
dos Santos, Paulo H. [2 ]
Berger, Sandrine [3 ]
Bedran-Russo, Ana Karina B. [1 ]
机构
[1] Univ Illinois, Coll Dent, Dept Restorat Dent, Chicago, IL USA
[2] Univ Estadual Paulista, Dept Dent Mat & Prosthodont, Aracatuba Sch Dent, Sao Paulo, Brazil
[3] Univ Estadual Campinas, Dept Restorat Dent, Dent Sch Piracicaba, Sao Paulo, Brazil
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2010年 / 104卷 / 04期
基金
巴西圣保罗研究基金会;
关键词
LUTING AGENTS; TANNIC-ACID; SMEAR LAYER; ENAMEL; COMPOSITES;
D O I
10.1016/S0022-3913(10)60134-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Self-adhesive cements have lower bond strength than conventional resin cements that rely on the application of etch-and-rinse adhesive systems. Purpose. The purpose of this study was to evaluate the effect of tannic and polyacrylic acid on the microtensile bond strength of self-adhesive resin cements to dentin. Material and methods. Eighteen molar crowns were flattened to expose dentin and divided into 3 groups according to the dentin pretreatment: (1) control, without surface treatment; (2) 25% polyacrylic acid solution (Ketac Conditioner); (3) 20% tannic acid. Composite resin (Tescera) blocks were luted to dentin surfaces using 2 self-adhesive resin cements (RelyX Unicem or Maxcem Elite) (n=3). All specimens were stored in distilled water for 24 hours, sectioned into beams (1 mm(2)), and tested to failure using a microtensile method at a crosshead speed of 1 mm/min. The data were statistically analyzed using 2-way ANOVA and Fisher's PLSD tests (alpha=.05). Results. The polyacrylic acid significantly improved the microtensile bond strength of RelyX Unicem (14.92 +/- 4.94 MPa) when compared to the control group (8.35 +/- 1.99 MPa) and tannic acid treatment (8.38 +/- 2.67 MPa) (P<.001). Dentin surface treatment did not affect the microtensile bond strength of Maxcem Elite cemented groups (control, 8.45 +/- 3.21 MPa; polyacrylic acid, 9.53 +/- 9.95 MPa; tannic acid, 6.89 +/- 4.45 MPa). Conclusions. Dentin pretreatment with polyacrylic acid improved the microtensile bond strength of RelyX Unicem. (J Prosthet Dent 2010; 104:258-264)
引用
收藏
页码:258 / 264
页数:7
相关论文
共 50 条
  • [31] Medium-term evaluation of the bond strength and dentin penetration of self-adhesive resin cements to root dentin
    Gelio, M. B.
    Zaniboni, J. F.
    Monteiro, J. C. C.
    Besegato, J. F.
    Pereira, J. R.
    Buchaim, R. L.
    Kuga, M. C.
    AUSTRALIAN DENTAL JOURNAL, 2024, 69 (02) : 93 - 101
  • [32] The Effect of Dentin Desensitizer on Shear Bond Strength of Conventional and Self-adhesive Resin Luting Cements After Aging
    Stawarczyk, B.
    Hartmann, R.
    Hartmann, L.
    Roos, M.
    Oezcan, M.
    Sailer, I.
    Haemmerle, C. H. F.
    OPERATIVE DENTISTRY, 2011, 36 (05) : 492 - 501
  • [33] Effect of Er:YAG Laser Irradiations on Shear Bond Strength of Three Self-Adhesive Resin Cements to Dentin
    Capa, Nuray
    Aykor, Arzu
    Ozel, Emre
    Calikkocaoglu, Senih
    Soyman, Mubin
    PHOTOMEDICINE AND LASER SURGERY, 2010, 28 (06) : 809 - 821
  • [34] The effect of dentin desensitizers, and Nd:YAG laser pre-treatment on microtensile bond strength of self-adhesive resin cement to dentin
    Acar, Ozlem
    Tuncer, Duygu
    Yuzugullu, Bulem
    Celik, Cigdem
    JOURNAL OF ADVANCED PROSTHODONTICS, 2014, 6 (02): : 88 - 95
  • [35] Bond strength of a self-adhesive resin cement to enamel and dentin
    Boas Fernandes, Virgillo Vilas, Jr.
    Rodrigues, Jose Roberto
    Ferraz da Silva, Joao Mauricio
    Pagani, Clovis
    Assuncao Souza, Rodrigo Othavio
    INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY, 2015, 10 (01): : 146 - 156
  • [36] Bond Strengths of Two Self-adhesive Resin Cements to Dentin with Different Treatments
    Chen, Chen
    He, Feng
    Burrow, Michael F.
    Xie, Haifeng
    Zhu, Ye
    Zhang, Feimin
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2011, 31 (01) : 73 - 77
  • [37] Bond strength of modern self-adhesive resin cements to human dentin and different CAD/CAM ceramics
    Malysa, Andrzej
    Wezgowiec, Joanna
    Danel, Dariusz
    Boening, Klaus
    Walczak, Katarzyna
    Wieckiewicz, Mieszko
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2020, 22 (02) : 25 - 34
  • [38] Evaluation of Bond Strength of Self-adhesive Cements to Dentin With or Without Application of Adhesive Systems
    Barcellos, Daphne Camara
    Batista, Graziela Ribeiro
    da Silva, Melissa Aline
    Rangel, Patricia Maria
    Gomes Torres, Carlos Rocha
    Fava, Marcelo
    JOURNAL OF ADHESIVE DENTISTRY, 2011, 13 (03): : 261 - 265
  • [39] Tensile bond strength of indirect composites luted with three new self-adhesive resin cements to dentin
    Turkmen, Cafer
    Durkan, Meral
    Cimilli, Hale
    Oksuz, Mustafa
    JOURNAL OF APPLIED ORAL SCIENCE, 2011, 19 (04) : 363 - 369
  • [40] Shear Bond Strength of Indirect Composites Luted with Three New Self-Adhesive Resin Cements to Dentin
    Turkmen, Cafer
    Durkan, Meral
    Oksuz, Mustafa
    JOURNAL OF ADHESION, 2009, 85 (12): : 919 - 931