Craniospinal irradiation with spinal IMRT to improve target homogeneity

被引:56
|
作者
Panandiker, Atmaram Pai
Ning, Holly
Likhacheva, Anna
Ullman, Karen
Arora, Barbara
Ondos, John
Karimpour, Shervin
Packer, Roger
Miller, Robert
Citrin, Deborah
机构
[1] NIH, NCI, Radiat Oncol Branch, Bethesda, MD 20892 USA
[2] Mem Reg Canc Ctr, Hollywood, FL USA
[3] George Washington Univ, Childrens Natl Med Ctr, Dept Neurol, Div Neurol & Pediat, Washington, DC USA
[4] George Washington Univ, Childrens Natl Med Ctr, Dept Pediat, Div Neurol & Pediat, Washington, DC USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2007年 / 68卷 / 05期
关键词
IMRT; craniospinal; homogeneity; pediatric; supine; RADIATION-THERAPY; MEDULLOBLASTOMA; PROTONS; PATIENT;
D O I
10.1016/j.ijrobp.2007.02.037
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To report a new technique for the spinal component of craniospinal irradiation (CSI) in the supine position, to describe a verification procedure for this method, and to compare this technique with conventional plans. Methods and Materials: Twelve patients were treated between 1998 and 2006 with CSI using a novel technique. Sixteen-children were treated with a conventional field arrangement. All patients were followed for outcomes and toxicity. CSI was delivered using a posteroanterior (PA) intensity-modulated radiation therapy (IMRT) spinal field matched to conventional, opposed lateral cranial fields. Treatment plans were generated for each patient using the IMRT technique and a standard PA field technique. The resulting dosimetry was compared to determine target homogeneity, maximum dose to normal tissues, and total monitor units delivered. Results: Evaluation of the spinal IMRT technique compared with a standard PA technique reveals a 7% reduction in the target volume receiving >= 110% of the prescribed dose and an 8% increase in the target volume receiving > 95% of the prescribed dose. Although target homogeneity was improved, the maximum dose delivered in the paraspinal muscles was increased by approximately 8.5% with spinal IMRT compared to the PA technique. Follow-up evaluations revealed no unexpected toxicity associated with the IMRT technique. Conclusions: A new technique of spine IMRT is presented in combination with a quality assurance method. This method improves target dose uniformity compared to the conventional CSI technique. Longer follow-up will be required to determine any benefit with regard to toxicity and disease control.
引用
收藏
页码:1402 / 1409
页数:8
相关论文
共 50 条
  • [31] Patterns of Failure after Craniospinal Irradiation, Intensity Modulated Radiation Therapy (IMRT) Boost and Chemotherapy for Medulloblastoma
    Paulino, A.
    Mazloom, A.
    South, M.
    Teh, B.
    Okcu, F.
    Su, J.
    Butler, E.
    Chintagumpala, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S507 - S508
  • [32] Late Effects of Craniospinal Irradiation Using Electron Spinal Fields for Pediatric Patients
    De, B.
    Ludmir, E. B.
    Maor, M. H.
    McGovern, S. L.
    McAleer, M. F.
    Grosshans, D. R.
    Woodhouse, K. D.
    Mahajan, A.
    Paulino, A. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E181 - E181
  • [33] Craniospinal Irradiation with Jagged-Junction IMRT Approach without Beam Edge Matching for Field Junctions
    Cao, F.
    Ramaseshan, R.
    Corns, R.
    Harrop, S.
    Nuraney, N.
    Steiner, P.
    Aldridge, S.
    Liu, M.
    Carolan, H.
    Agranovich, A.
    Karva, A.
    MEDICAL PHYSICS, 2012, 39 (07) : 4635 - 4635
  • [34] Feasibility of Virtual Reality-based target volume delineation for craniospinal irradiation
    Volpini, M.
    Jooya, A.
    La Russa, D.
    Sutherland, J.
    Samant, R.
    Nair, V.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1454 - S1454
  • [35] Practical dose delivery verification of craniospinal IMRT
    Lee, Young K.
    Kim, Anthony T.
    Zhao, Peiying
    Karotki, Aliaksandr
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (06): : 76 - 83
  • [36] Improved dose homogeneity with forward planning IMRT (f-IMRT) for intact breast and axillary/supraclavicular field irradiation.
    Cavey, ML
    Pena, J
    Endres, EJ
    Bayouth, JE
    Hatch, S
    BREAST CANCER RESEARCH AND TREATMENT, 2003, 82 : S40 - S40
  • [37] Late Effects of Craniospinal Irradiation Using Electron Spinal Fields for Pediatric Patients With Cancer
    De, Brian
    Florez, Marcus A.
    Ludmir, Ethan B.
    Maor, Moshe H.
    McGovern, Susan L.
    McAleer, Mary Frances
    Grosshans, David R.
    Chang, Eric L.
    Mahajan, Anita
    Paulino, Arnold C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 115 (01): : 164 - 173
  • [38] OPTIMAL NORMAL TISSUE SPARING IN CRANIOSPINAL AXIS IRRADIATION USING IMRT WITH DAILY INTRAFRACTIONALLY MODULATED JUNCTION(S)
    Kusters, Johannes M. A. M.
    Louwe, Rob J. W.
    van Kollenburg, Peter G. M.
    Kunze-Busch, Martina C.
    Gidding, Corrie E. M.
    van Lindert, Erik J.
    Kaanders, Johannes H. A. M.
    Janssens, Geert O. R. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (05): : 1405 - 1414
  • [39] To Reduce Hot Dose Spots in Craniospinal Irradiation: A Two-Field IMRT Approach with Matching Beam Divergence
    Rahman, A.
    Montebello, J.
    Lu, L.
    Gupta, N.
    Huang, Z.
    Mayr, N.
    Wang, J.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [40] Craniospinal radiotherapy in children: Electron- or photon-based technique of spinal irradiation
    Chojnacka, Marzanna
    Skowronska-Gardas, Anna
    Morawska-Kaczynska, Marzena
    Zygmuntowicz-Pietka, Anna
    Pedziwiatr, Katarzyna
    Semaniak, Anna
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2010, 15 (01) : 21 - 24