Wind-induced pressure at external surfaces of a high-rise residential building in Hong Kong

被引:34
|
作者
Burnett, J
Bojic, M
Yik, F
机构
[1] Univ Kragujevac, Fac Mech Engn, YU-34000 Kragujevac, Serbia
[2] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
CFD; wind; cross-ventilation;
D O I
10.1016/j.buildenv.2004.08.019
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The paper presents results of computational fluid dynamics simulations of pressure at external surfaces of a typical high-rise residential building in Hong Kong in order to comment on wind-driven ventilation inside the flats. The simulations used k - epsilon turbulence model, and two and three-dimensional model of the building. The results reveal that an optimal building orientation relative to the wind can be found; the windward flats possess the best cross-ventilation potential; in the investigated flats, location of windows and rooms is not adequate to maximize cross-ventilation potential and minimize spread of odour. The new building plan provides better cross-ventilation. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:765 / 777
页数:13
相关论文
共 50 条
  • [21] Building design and energy end-use characteristics of high-rise residential buildings in Hong Kong
    Wan, KSY
    Yik, FWH
    APPLIED ENERGY, 2004, 78 (01) : 19 - 36
  • [22] Impact of urban heat island on high-rise residential building cooling energy demand in Hong Kong
    Ma, Yichuan X.
    Yu, Ava C.
    ENERGY AND BUILDINGS, 2024, 311
  • [23] Wind-induced vibration response of super high-rise building in high-turbulence flow
    Department of Civil Engineering, Shantou University, Shantou 515063, China
    不详
    Jianzhu Jiegou Xuebao, 2006, 6 (94-100):
  • [24] Wind-induced vibration control of energy dissipation outrigger on a super high-rise building
    Lu, Zheng
    He, Xiangdong
    PROCEEDINGS OF THE 2016 5TH INTERNATIONAL CONFERENCE ON CIVIL, ARCHITECTURAL AND HYDRAULIC ENGINEERING (ICCAHE 2016), 2016, 95 : 987 - 992
  • [25] Field measurement of wind-induced stress on glass facade of a coastal high-rise building
    Li ZhengNong
    Luo DieFeng
    Shi WenHai
    Li ZhiQi
    Liang XiaoHan
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2011, 54 (10) : 2587 - 2596
  • [26] Field measurement of wind-induced stress on glass facade of a coastal high-rise building
    LI ZhengNong~1*
    2 College of Architecture and Civil Engineering of Wenzhou University
    Science China(Technological Sciences), 2011, (10) : 2587 - 2596
  • [27] Full-scale measurement of wind-induced internal pressures in a high-rise building
    Kato, N.
    Niihori, Y.
    Kurita, T.
    Ohkuma, T.
    Journal of Wind Engineering and Industrial Aerodynamics, 1997, 69-71 : 619 - 630
  • [28] Full-scale measurement of wind-induced internal pressures in a high-rise building
    Kato, N
    Niihori, Y
    Kurita, T
    Ohkuma, T
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1997, 71 : 619 - 630
  • [29] Wind-induced natural ventilation of re-entrant bays in a high-rise building
    Cheng, C. K. C.
    Lam, K. M.
    Leung, Y. T. A.
    Yang, K.
    Danny, H. W. Li
    Sherman, C. P. Cheung
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2011, 99 (2-3) : 79 - 90
  • [30] Wind-induced torsion vibration of the super high-rise building of Shenzhen Energy Center
    Feng Ruo-qiang
    Ye Jihong
    Yan, Guirong
    Li Qing-xiang
    Bin, Yao
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2013, 22 (10): : 802 - 815