Analysis of three optimization techniques in a treatment planning system

被引:0
|
作者
Hu, Z [1 ]
Chu, J [1 ]
机构
[1] Rush Univ, Med Ctr, Chicago, IL 60612 USA
关键词
D O I
10.1118/1.1997692
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop the biological and dosimetric based tools for the evaluation of the treatment plans. Method and Materials: We have developed a set of treatment planning evaluation tools based on the equivalent uniform dose(EUD), Coverage Index(CI), Homogeneity Index(HI) and Overdose Index(OI) to evaluate the HDR brachytherapy treatment plans. Three different optimization techniques in PLATO treatment planning system are used for CT based 3D conformal brachytherapy: geometric optimization(GO), inverse optimization(IO), and the optimization to the dose points on the surface of the tumor volume(SO). All reference doses are prescribed to the points on the PTV surfaces. Treatment plans of 10 patients are analyzed. Results: The GO techniques has the best dose uniformity(mean HI=0.60) but poorest target volume coverage(mean CI=0.71). The SO method provides the best coverage(mean CI=0.85) and lowest homogeneity(mean HI=0.62). The IO plans show a compromise between coverage and dose homogeneity(mean CI=0.52 and HI=0.43). CI and EUD show close correlation for plans produced by all three optimization techniques. Conclusion: Our study suggests that these dosimetric indices could be useful tools in the evaluation of the CT based 3D conformal brachytherapy planning. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1954 / 1954
页数:1
相关论文
共 50 条
  • [21] Agility MLC transmission optimization in the Monaco treatment planning system
    Roche, Michael
    Crane, Robert
    Powers, Marcus
    Crabtree, Timothy
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05): : 473 - 482
  • [22] OPTIMIZATION OF THE WEDGE FILTER PARAMETERS FOR A RADIOTHERAPY TREATMENT PLANNING SYSTEM
    WILLEMSE, CA
    DUVENAGE, J
    LOTTER, MG
    MINNAAR, PC
    GOEDHALS, L
    MEDICAL PHYSICS, 1989, 16 (03) : 352 - 356
  • [23] Dosimetric evaluation of a three-dimensional treatment planning system
    Murugan, Appasamy
    Valas, Xavier Sidonia
    Thayalan, Kuppusamy
    Ramasubramanian, Velayudham
    JOURNAL OF MEDICAL PHYSICS, 2011, 36 (01) : 15 - 21
  • [24] Generation Expansion Planning Considering Reliability of the System: A Review on Various Optimization Techniques
    Ballireddy, Tulasi RamaKrishna Rao
    Modi, Pawan Kumar
    2017 INTERNATIONAL CONFERENCE OF ELECTRONICS, COMMUNICATION AND AEROSPACE TECHNOLOGY (ICECA), VOL 2, 2017, : 137 - 142
  • [25] APPLICATION OF COMPUTER SIMULATION TECHNIQUES TO WATER SYSTEM ANALYSIS AND PLANNING
    HENNESSY, JJ
    UPHOFF, RL
    MECHANICAL ENGINEERING, 1970, 92 (06) : 78 - &
  • [26] Automatic Planning for Nasopharyngeal Carcinoma Based on Progressive Optimization in RayStation Treatment Planning System
    Yang, Yiwei
    Shao, Kainan
    Zhang, Jie
    Chen, Ming
    Chen, Yuanyuan
    Shan, Guoping
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2020, 19
  • [27] OPTIMIZATION TECHNIQUES FOR SECONDARY WASTE-WATER TREATMENT SYSTEM
    TANG, CC
    BRILL, ED
    PFEFFER, JT
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1987, 113 (05): : 935 - 951
  • [28] Genetic and geometric optimization of three-dimensional radiation therapy treatment planning
    Ezzell, GA
    MEDICAL PHYSICS, 1996, 23 (03) : 293 - 305
  • [29] A global optimization method for three-dimensional conformal radiotherapy treatment planning
    Wu, XG
    Zhu, YP
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (01): : 107 - 119
  • [30] COMPLICATION-CONTROL ANALYSIS APPLIED TO TREATMENT PLANNING OPTIMIZATION
    SCHULTHEISS, TE
    ORTON, CG
    PECK, RA
    MEDICAL PHYSICS, 1980, 7 (04) : 427 - 427