Evaluation of Four Qualitative Third-Generation HIV Antibody Assays and the Fourth-Generation Abbott HIV Ag/Ab Combo Test

被引:3
|
作者
Wians, Frank H. [1 ]
Moore, Holly A. [1 ]
Briscoe, Donna [1 ]
Anderson, Kathy M. [1 ]
Hicks, Pamela S. [2 ]
Smith, Debbie L. [2 ]
Clark, Tammy A. [3 ]
Preton, Maggie M.
Gammons, Beckie
Ray, Cynthia S.
Bond, Christine
West, Joshua T.
机构
[1] Baylor Univ, Med Ctr, Dept Pathol, Dallas, TX USA
[2] Texas Hlth Arlington Mem Hosp, Arlington, TX USA
[3] Texas Hlth Preshyterian Hosp, Baylor All Saims, Dallas, TX USA
来源
LABMEDICINE | 2011年 / 42卷 / 09期
关键词
human immunodeficiency virus; fourth-generation assay; comparative method; test method; agreement; P24; ANTIGEN; VIRUS; DIAGNOSIS; RISK;
D O I
10.1309/LM38NCGQ0GWJIMZV
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective: Compare the agreement between four third-generation rapid or automated human immunodeficiency virus (HIV) tests vs the fourth-generation Abbott ARCHITECT HIV Ag/Ab Combo assay (Combo Test) (Abbott Laboratories, Abbott Park, IL) in 7 clinical laboratories located throughout the Dallas-Fort Worth, TX, metroplex area. Methods: We tested a total of 220 specimens from the general population of patients being screened for HIV antibody status, including Western blot (WB) and HIV-1 RNA viral load by NAAT in patients with initially positive HIV screening tests. We performed a method precision study of the Combo Test and evaluated the agreement between the 4 comparative methods (CMs) against the Combo Test method (TM) using a 2 x 2 contingency table to determine values for positive percent agreement (PPA), negative percent agreement (NPA), and overall percent agreement (OPA) according to the guideline (EP12-A2) for the evaluation of qualitative assays published by the Clinical Laboratory Standards Institute (CLSI). Results: The Combo Test yielded consistent (reproducible) results when the HIV antibody (or p24 antigen) concentration was 20% away or more from C-50. In addition, values for PPA, NPA, and OPA for CM vs TM result's were all 100%, or not significantly different from 100%. Conclusion: The high detection rate of the Combo Test, when coupled with its high diagnostic sensitivity and specificity, rapid TAT (<30 minutes) of test results using a fully automated instrument (ARCHITECT), and excellent agreement with HIV-1/2 antibody results by several commercially available HIV-1/2 screening tests and with WB and NAAT results, indicate that the Abbott HIV-1/2 Ab/Ag Test is a useful screening test in the identification of HIV-infected individuals.
引用
收藏
页码:523 / 535
页数:13
相关论文
共 50 条
  • [31] Heterophilic interference in specimens yielding false-reactive results on the Abbott 4th generation ARCHITECT HIV Ag/Ab Combo assay
    Lavoie, S.
    Caswell, D.
    Gill, M. J.
    Kadkhoda, K.
    Charlton, C. L.
    Levett, P. N.
    Hatchette, T.
    Garceau, R.
    Maregmen, J.
    Mazzulli, T.
    Needle, R.
    Kadivar, K.
    Kim, J.
    JOURNAL OF CLINICAL VIROLOGY, 2018, 104 : 23 - 28
  • [32] False-positive fourth-generation HIV test result in a woman with Plasmodium malariae malaria
    Ainoda, Yusuke
    Komaki-Yasuda, Kanako
    Kano, Shigeyuki
    Hirai, Yuji
    TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2023, 117 (02) : 147 - 148
  • [33] Comparative evaluation of TRI-DOT Rapid HIV test with fourth-generation ELISA for the detection of human immunodeficiency virus
    Sudha, T
    Teja, VD
    Gopal, M
    Rajesh, M
    Lakshmi, V
    CLINICAL MICROBIOLOGY AND INFECTION, 2005, 11 (10) : 850 - 852
  • [34] Clinical evaluation of the fourth-generation immunodiagnostic reagents "Elecsys HIV Duo" for screening HIV in specimens from Korean subjects
    Won, D. J.
    Choi, D.
    Kim, H.
    CLINICA CHIMICA ACTA, 2019, 493 : S53 - S54
  • [35] Performance of three automated fourth-generation combined HIV antigen/antibody assays in large-scale screening of blood donors and clinical samples
    Malm, K.
    von Sydow, M.
    Andersson, S.
    TRANSFUSION MEDICINE, 2009, 19 (02) : 78 - 88
  • [36] Evaluation of fourth-generation HIV screening assays to detect one case of human immunodeficiency virus-1 during seroconversion window
    Omoto, R.
    Eiras, A.
    Falcao, S.
    de Araujo, F. L. Vieira
    TRANSFUSION, 2006, 46 (09) : 101A - 101A
  • [37] Avidity Index for Anti-HIV Antibodies: Comparison between Third- and Fourth-Generation Automated Immunoassays
    Suligoi, Barbara
    Rodella, Anna
    Raimondo, Mariangela
    Regine, Vincenza
    Terlenghi, Luigina
    Manca, Nino
    Casari, Salvatore
    Camoni, Laura
    Salfa, Maria Cristina
    Galli, Claudio
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (07) : 2610 - 2613
  • [38] Comparative Evaluation of Two 4th-Generation HIV Combo Assays using a Genetically Diverse HIV Panel and Diagnostic Specimens
    Qiu, X.
    Sokoll, L.
    Elliott, D. J.
    Dua, R.
    Mohr, P.
    Swanson, P.
    Dawson, G. J.
    TRANSFUSION, 2016, 56 : 186A - 187A
  • [39] Evaluation of a fully automated, fourth generation immunoassay for the simultaneous detection of HIV antigen and antibody
    Constantine, NT
    Saville, RD
    Sobus, M
    Cleghorn, FR
    Jack, N
    Bartholomew, C
    Edwards, J
    Blattner, WA
    AIDS, 2000, 14 : S105 - S105
  • [40] Low rates of p24 antigen detection using a fourth-generation point of care HIV test
    Fox, Julie
    Dunn, Helen
    O'Shea, Siobhan
    SEXUALLY TRANSMITTED INFECTIONS, 2011, 87 (02) : 178 - 179