A Hybrid Textile Electrode for Electrocardiogram (ECG) Measurement and Motion Tracking

被引:63
|
作者
An, Xiang [1 ]
Stylios, George K. [1 ]
机构
[1] Heriot Watt Univ, Res Inst Flexible Mat, Edinburgh TD1 3HF, Midlothian, Scotland
关键词
textile electrode; ECG; motion sensor; skin-electrode impedance; HEALTH-CARE-SYSTEM; SUDDEN-DEATH; IMPEDANCE; INTEGRATION; EXERCISE; EXERTION; SENSORS;
D O I
10.3390/ma11101887
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Wearable sensors have great potential uses in personal health monitoring systems, in which textile-based electrodes are particularly useful because they are comfortable to wear and are skin and environmentally friendly. In this paper, a hybrid textile electrode for electrocardiogram (ECG) measurement and motion tracking was introduced. The hybrid textile electrode consists of two parts: A textile electrode for ECG monitoring, and a motion sensor for patient activity tracking. In designing the textile electrodes, their performance in ECG measurement was investigated. Two main influencing factors on the skin-electrode impedance of the electrodes were found: Textile material properties, and electrode sizes. The optimum textile electrode was silver plated, made of a high stitch density weft knitted conductive fabric and its size was 20 mm x 40 mm. A flexible motion sensor circuit was designed and integrated within the textile electrode. Systematic measurements were performed, and results have shown that the hybrid textile electrode is capable of recording ECG and motion signals synchronously, and is suitable for ambulatory ECG measurement and motion tracking applications.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Measurement of skin-electrode impedance for a 12-lead electrocardiogram
    Zepeda-Carapia, I
    Márquez-Espinoza, A
    Alvarado-Serrano, C
    2005 2nd International Conference on Electrical & Electronics Engineering (ICEEE), 2005, : 193 - 195
  • [42] Continuous Electrocardiogram (ECG) measurement via optimization of electrochemical state of a conductive polymer on fabric
    Sinha, Sneh
    Noh, Yeon Sik
    Treich, Gregory
    Alipour, Shirin
    Chon, Ki
    Sotzing, Gregory
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [43] Evaluation of NISHIJIN e-Textile for 12-lead ECG measurement through Automatic ECG Analyzer
    Kuroda, Tomohiro
    Shiomi, Hiroki
    Minamino-Muta, Eri
    Yamashita, Yugo
    Iwao, Tomohide
    Tamura, Hiroshi
    Ueshima, Kazuo
    Kimura, Takeshi
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 1234 - 1237
  • [44] Patient Motion Tracking in the Presence of Measurement Errors
    Haidegger, Tamas
    Benyo, Zoltan
    Kazanzides, Peter
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 5563 - +
  • [45] Limb Motion Tracking with Inertial Measurement Units
    Widagdo, Prabancoro Adhi Catur
    Lee, Hsin-Huang
    Kuo, Chung-Hsien
    2017 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2017, : 582 - 587
  • [46] A 2.4μA Continuous-time Electrode-Skin Impedance Measurement Circuit For Motion Artifact Monitoring in ECG Acquisition Systems
    Kim, Sunyoung
    Yazicioglu, Refet Firat
    Torfs, Tom
    Dilpreet, Buxi
    Julien, Penders
    Van Hoof, Chris
    2010 SYMPOSIUM ON VLSI CIRCUITS, DIGEST OF TECHNICAL PAPERS, 2010, : 219 - +
  • [47] A mathematical model for derivation of Elevated-Electrode-Placement Electrocardiogram (EEP-ECG) leads from a standard 12-lead electrocardiogram
    Kalani, Karan
    Selvaraj, Raja
    Nair, Sreekumaran
    Satheesh, Santhosh
    Anantharaj, Avinash
    Ahmed, Shaheer
    Sukumaran, Suresh Kumar
    Bhargav, Anish
    Balaguru, Sridhar
    JOURNAL OF ELECTROCARDIOLOGY, 2025, 89
  • [48] Time based measurement of the impedance of the skin-electrode interface for dry electrode ECG recording
    Dozio, Roberta
    Baba, Adeshina
    Assambo, Cedric
    Burke, Martin J.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 5001 - 5004
  • [49] A Novel Wearable Flexible Dry Electrode Based on Cowhide for ECG Measurement
    Huang, Yiping
    Song, Yatong
    Gou, Li
    Zou, Yuanwen
    BIOSENSORS-BASEL, 2021, 11 (04):
  • [50] Development and Evaluation of One Arm Electrode Based ECG Measurement System
    Hannula, M.
    Hinkula, H.
    Jauhiainen, J.
    14TH NORDIC-BALTIC CONFERENCE ON BIOMEDICAL ENGINEERING AND MEDICAL PHYSICS, 2008, 20 : 234 - 237