Effectiveness of four electronic apex locators to determine distance from the apical foramen

被引:42
|
作者
Stoll, R. [1 ]
Urban-Klein, B. [1 ]
Roggendorf, M. J. [1 ]
Jablonski-Momeni, A. [2 ]
Strauch, K. [3 ]
Frankenberger, R. [1 ]
机构
[1] Univ Marburg, Dept Operat Dent & Endodont, Sch Dent, D-35033 Marburg, Germany
[2] Univ Marburg, Dept Pediat Dent, Sch Dent, D-35033 Marburg, Germany
[3] Univ Marburg, Inst Med Biometry & Epidemiol, D-35033 Marburg, Germany
关键词
apical region; electronic apex locator; meter reading display; root canal length determination; IN-VITRO EVALUATION; WORKING LENGTH DETERMINATION; ENLARGED ROOT CANALS; VIVO ACCURACY; ZX; CONSTRICTION; SIZE;
D O I
10.1111/j.1365-2591.2010.01765.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
P>Aim To evaluate the accuracy of four electronic apex locators (EAL) in the apical region (0-3 mm short of the foramen) and to compare the precision of the readings on the display with the real position of the file in the root canal. Methodology Twenty single-rooted extracted teeth with round root canals were used. The canal orifices were preflared, and the length to the major foramen was determined visually under a microscope. Canals were enlarged, so that a size 15 file fitted well inside the canal. Teeth were mounted in acrylic test tubes filled with physiologic saline solution. Electronic length was determined in the region between the major foramen and 3 mm short of it in 0.5 mm steps with the Dentaport ZX, Root ZX mini, Elements Diagnostic Unit and Apex Locator and Raypex 5 using files of size 10 and size 15. The data were analysed using linear regression between true length and EAL reading, Bland-Altman plots and nonparametric tests at a significance level of alpha = 0.05. Results The major foramen was detected by all EALs. With a measurement file positioned directly at the major foramen, meter readings were equivalent to a position 0.01-0.38 mm away. For the Dentaport ZX, a better accuracy using the size 15 file for the area 0-1.5 mm short of the apex was found. The differences in measurements between the two files were smaller for the other EALs. In linear regression, a good linearity for Dentaport ZX and Root ZX mini and moderate linearity for Elements Diagnostic Unit and Apex Locator and Raypex 5 were found. The slope of the measurement curve was too low (0.37-0.57) for the Raypex 5 and almost optimal for the Dentaport ZX (1.01-1.05). The Root ZX mini and the Elements Obturation Unit produced lower slope values and especially the Elements Obturation Unit revealed much higher SDs at the different measurement levels. Conclusion Amongst the four EALs, the Dentaport ZX and Root ZX mini had the best agreement between true lengths and meter readings. For the Raypex 5, an interpretation of the colour-coded zones as distance to the foramen cannot be recommended and might lead to erroneous interpretations.
引用
收藏
页码:808 / 817
页数:10
相关论文
共 36 条
  • [31] Accuracy and stability of electronic apex locator length measurements in root canals with wide apical foramen: an ex vivo study
    Shacham, Maayan
    Levin, Avi
    Shemesh, Avi
    Lvovsky, Alex
    Ben Itzhak, Joe
    Solomonov, Michael
    BDJ OPEN, 2020, 6 (01)
  • [32] Accuracy and stability of electronic apex locator length measurements in root canals with wide apical foramen: an ex vivo study
    Maayan Shacham
    Avi Levin
    Avi Shemesh
    Alex Lvovsky
    Joe Ben Itzhak
    Michael Solomonov
    BDJ Open, 6
  • [33] In vivo determination of the frequency response of the tooth root canal impedance versus distance from the apical foramen
    Rambo, Marcos V. H.
    Gamba, Humberto R.
    Ratzke, Alexandre S.
    Schneider, Fabio K.
    Maia, Joaquim M.
    Ramos, Carlos A. S.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 570 - +
  • [34] Reviewing the effectiveness of electronic vehicle immobilisation: Evidence from four countries
    Rick Brown
    Security Journal, 2015, 28 : 329 - 351
  • [35] Reviewing the effectiveness of electronic vehicle immobilisation: Evidence from four countries
    Brown, Rick
    SECURITY JOURNAL, 2015, 28 (04) : 329 - 351
  • [36] Short-term effectiveness of face-to-face periodic occupational health screening versus electronic screening with targeted follow-up: results from a quasi-randomized controlled trial in four Belgian hospitals
    Steel, Jonas Stefaan
    Godderis, Lode
    Luyten, Jeroen
    SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 2022, 48 (03) : 220 - 228