Single Drop Electroanalysis and Interfacial Interactions: Sensitivity versus Limit of Detection

被引:4
|
作者
Walgama, Charuksha [1 ]
Gallman, Matthew [1 ]
Krishnan, Sadagopan [1 ]
机构
[1] Oklahoma State Univ, Dept Chem, Stillwater, OK 74078 USA
基金
美国国家卫生研究院;
关键词
Single drop analysis; Interfacial interactions; Sensitivity; Detection limit; Sensor surface; Real samples; SCREEN-PRINTED ELECTRODES; ELECTROCHEMICAL SENSORS; GLUCOSE SENSORS; ASCORBIC-ACID; URIC-ACID; GRAPHENE; MICROFLUIDICS; ACETAMINOPHEN; BIOSENSOR; DOPAMINE;
D O I
10.1002/elan.201600271
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report single drop electroanalytical measurements of pharmaceutically and biologically relevant compounds using screen printed electrodes (SPEs) modified with carboxylated multiwalled carbon nanotubes (MWCNT-COOH) as the sensor surface. Acetaminophen, nicotine, ascorbic acid, and nicotinamide adenine dinucleotide reduced form (NADH) were detected in a single drop of solution. We show that combined polar and nonpolar interactions of analytes with -COOH functional groups and large surface area of MWCNT, respectively, allow highly sensitive analyte detection with wide dynamic range. Smaller analytes can bind to a significantly greater number of sensor sites than the bulkier analytes and offer better detection sensitivity. Results suggest that sensitivity is controlled by predominant nonpolar interactions that an analyte can undergo with the MWCNT-COOH SPE sensor surface, whereas limit of detection is controlled by the extent of polar interactions between an analyte and the sensor surface, facilitating interfacial charge transport and an electrochemical signal output. Furthermore, a combination of polar and nonpolar analyte interactions with the sensor surface shows a synergistic effect on sensitivity and detection limit. This could be a likely reason for why sensitivity does not need to always correlate with lower detection limits as variations in the interfacial interactions are critical. Application of the designed single drop method to real samples was validated by estimating the amounts of acetaminophen, nicotine, ascorbic acid, and NADH in commercially available pharmaceuticals with excellent recovery.
引用
收藏
页码:2791 / 2796
页数:6
相关论文
共 50 条
  • [41] SINGLE IMMUNODIFFUSION DROP TEST FOR DETECTION OF LILY SYMPTOMLESS VIRUS
    VANSLOGTEREN, DHM
    ANNALS OF APPLIED BIOLOGY, 1976, 82 (01) : 91 - &
  • [42] Headspace single-drop microextration for the detection of organotin compounds
    Colombini, V
    Bancon-Montigny, C
    Yang, L
    Maxwell, P
    Sturgeon, RE
    Mester, Z
    TALANTA, 2004, 63 (03) : 555 - 560
  • [43] Quantile-based versus Sobol sensitivity analysis in limit state design
    Kala, Zdenek
    STRUCTURES, 2020, 28 : 2424 - 2430
  • [44] On the sensitivity limit of positron annihilation: detection of vacancies in as-grown silicon
    Gebauer, J
    Rudolf, F
    Polity, A
    Krause-Rehberg, R
    Martin, J
    Becker, P
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1999, 68 (04): : 411 - 416
  • [45] OSCILLOMETRIC DETECTOR FOR ION CHROMATOGRAPHY - A NOTE ON DETECTION LIMIT AND DETECTOR SENSITIVITY
    PAL, F
    PUNGOR, E
    KOVATS, ES
    ANALYTICAL CHEMISTRY, 1988, 60 (20) : 2254 - 2258
  • [46] On the sensitivity limit of positron annihilation: detection of vacancies in as-grown silicon
    J. Gebauer
    F. Rudolf
    A. Polity
    R. Krause-Rehberg
    J. Martin
    P. Becker
    Applied Physics A, 1999, 68 : 411 - 416
  • [47] On the sensitivity limit of positron annihilation: detection of vacancies in as-grown silicon
    Gebauer, J.
    Rudolf, F.
    Polity, A.
    Krause-Rehberg, R.
    Martin, J.
    Becker, P.
    Applied Physics A: Materials Science and Processing, 1999, 68 (04): : 411 - 416
  • [48] Improvement of Sensitivity and Limit of Detection in a Nanogap Biosensor by Controlling Surface Wettability
    Kim C.-H.
    Ahn J.-H.
    Kim J.-Y.
    Choi J.-M.
    Park T.J.
    Choi Y.-K.
    BioNanoScience, 2013, 3 (2) : 192 - 197
  • [49] Sensitivity and detection limit analysis of silicon nanowire bio(chemical) sensors
    Chen, Songyue
    van den Berg, Albert
    Carlen, Edwin T.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 209 : 486 - 489
  • [50] Sensitivity, Prediction Uncertainty, and Detection Limit for Artificial Neural Network Calibrations
    Allegrini, Franco
    Olivieri, Alejandro C.
    ANALYTICAL CHEMISTRY, 2016, 88 (15) : 7807 - 7812