Over 10 years with an implantable cardioverter-defibrillator - a long term follow-up of 60 patients

被引:0
|
作者
Sterlinski, Maciej [1 ]
Przybylski, Andrzej [1 ]
Gepner, Katarzyna [1 ]
Syska, Pawel [1 ]
Maciag, Aleksander [1 ]
Lewandowski, Michal [1 ]
Kowalik, Ilona [1 ]
Pytkowski, Manusz [1 ]
Sitkowska-Rysiak, Ewa [1 ]
Lichomski, Jerzy [1 ]
Szwed, Hanna [1 ]
Sadowski, Zygmunt [1 ]
机构
[1] Inst Cardiol, PL-02637 Warsaw, Poland
关键词
implantable cardioverter defibrillator; long term observation; survival; appropriate and inappropriate interventions; complications; SUDDEN CARDIAC DEATH; MYOCARDIAL-INFARCTION; TEMPORAL TRENDS; UNITED-STATES; HIGH-RISK; THERAPY; PREVENTION; EXPERIENCE; RECIPIENTS; SURVIVAL;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Transvenous implantable cardioverter defibrillators (ICD) have been implanted in Poland since 1995 As the method spreads it is important to consider its long-term benefits and disadvantages Aim To assess survival efficacy and complication rate in ICD patients, who received the device more than ten years earlier Methods Retrospective analysis of 60 ICD patients implanted between 1995-1999 Results There were 42 (70%) males, mean age 50 6 +/- 16 4 years In 59 patients ICD was implanted for sudden cardiac death (SCD) secondary prevention Thirty eight patients (34 M, 63 3%) had coronary artery disease (CAD) The CAD was diagnosed in 89 5% of males and 10 5% of females (p < 0 0001) Mean follow-up time was 75 4 +/- 34 7 months During this time 22 patients died (37%, 19 M, 3 F) Three deaths were SCD Mean one-year mortality was 6 7% Deaths were more frequent among males 45 2% vs 16 7%, p < 0 005 In CAD mortality was higher than in non-CAD patients (50% vs 13 6% p < 0 005) Appropriate ICD discharges in the ventricular fibrillation (VF) zone occurred in 35 (58%) patients and in ventricular tachycardia (VT) zone - in 26 (43%) patients Mean intervention rate per year was 3 7 for VF and 0 6 for VT Complications occurred in 27 (45%) patients and 5 (8%) of them had no ICD intervention during follow-up In 5 patients more than one complication was diagnosed There were inappropriate discharges in 15 (25%) patients, 11 (18%) had electrical storm and ICD related infections were noted in 3 (5%) patients During the penoperative period, lead revisions were done in 4 patients, in 3 with discharges induced by T-wave oversensing and in one with lead dislocation Four cases of lead failure occurred during follow up, requiring new lead implantation In 4 patients, electrical storm (3 patients) and supraventricular tachycardia with ICD discharges (1 patient) were treated with radiofrequency ablation Only 10 (17%) patients did not demonstrate any ICD interventions or ICD related complications Conclusions 1 ICD interventions caused by malignant ventricular arrhythmias occurred in 75% patients with the device implanted more than 10 years earlier 2 Almost a half of the analysed population suffered from complications and side effects related to implanted ICD and they were present in 8% of subjects without ICD intervention Neither ICD interventions nor device related adverse events were recorded in 17% of patients
引用
收藏
页码:1023 / 1031
页数:9
相关论文
共 50 条
  • [31] Long-term follow-up of arrhythmogenic right ventricular cardiomyopathy patients with an implantable cardioverter-defibrillator for prevention of sudden cardiac death
    Yin, Kang
    Ding, Ligang
    Li, Yuqiu
    Hua, Wei
    CLINICAL CARDIOLOGY, 2017, 40 (04) : 216 - 221
  • [32] Long-term follow-up of implantable cardioverter, defibrillator therapy for hypertrophic cardiomyopathy
    Jayatilleke, I
    Doolan, A
    Ingles, J
    McGuire, M
    Booth, V
    Richmond, DR
    Semsarian, C
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (09): : 1192 - 1194
  • [33] Subcutaneous implantable cardioverter-defibrillator electrode fracture: Follow-up, troubleshooting, and evaluation
    Kella, Danesh K.
    Stambler, Bruce S.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (05) : 1452 - 1457
  • [34] Impact of programming in a large cohort of implantable cardioverter-defibrillator patients with long-term follow-up: findings from the UMBRELLA study
    Briongos Figuero, S.
    Garcia Alberola, A.
    Rubio, J. B.
    Segura, J. M.
    Rodriguez, A.
    Peinado, R.
    Alzueta, J.
    Martinez Ferrer, J. B.
    Vinolas, X.
    Munoz-Aguilera, R.
    Perez, M. L.
    EUROPEAN HEART JOURNAL, 2021, 42 : 394 - 394
  • [35] Long-term follow-up of adult patients with congenital heart disease and an implantable cardioverter defibrillator
    Cruz, Madalena Coutinho
    Monteiro, Andre Viveiros
    Portugal, Guilherme
    Laranjo, Sergio
    Lousinha, Ana
    Valente, Bruno
    Osorio, Paulo
    Cunha, Pedro Silva
    de Sousa, Lidia
    Oliveira, Jose Alberto
    Agapito, Ana
    Oliveira, Mario Martins
    Pinto, Fatima
    Ferreira, Rui Cruz
    CONGENITAL HEART DISEASE, 2019, 14 (04) : 525 - 533
  • [36] THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - CLINICAL-EXPERIENCE, COMPLICATIONS, AND FOLLOW-UP IN 25 PATIENTS
    BORBOLA, J
    DENES, P
    EZRI, MD
    HAUSER, RG
    SERRY, C
    GOLDIN, MD
    ARCHIVES OF INTERNAL MEDICINE, 1988, 148 (01) : 70 - 76
  • [37] Implantable cardioverter/defibrillator (ICD) follow-up
    Gwechenberger, M.
    JOURNAL FUR KARDIOLOGIE, 2023, 30 (11-12): : 276 - 280
  • [38] Clinical course of implantable cardioverter-defibrillator patients; prolonged follow-up in routine clinical practice
    Van der Heijden, A. C.
    Buiten, M. S.
    Thijssen, J.
    Van Rees, J. B.
    Erven, L.
    Schalij, M. J.
    Borleffs, C. J. W.
    EUROPEAN HEART JOURNAL, 2014, 35 : 49 - 49
  • [39] Long-Term Prognosis of Patients with an Implantable Cardioverter-Defibrillator in Korea
    Uhm, Jae-Sun
    Kim, Tae-Hoon
    Kim, In-Cheol
    Park, Young-Ah
    Shin, Dong Geum
    Lim, Yeong-Min
    Yu, Hee-Tae
    Yang, Pil-Sung
    Pak, Hui-Nam
    Kang, Seok-Min
    Lee, Moon-Hyoung
    Joung, Boyoung
    YONSEI MEDICAL JOURNAL, 2017, 58 (03) : 514 - 520
  • [40] Relation of multicenter automatic defibrillator implantation trial implantable cardioverter-defibrillator score with long-term cardiovascular events in patients with implantable cardioverter-defibrillator
    Uslu, Abdulkadir
    Dogan, Cem
    Duman, Hakan
    Tanboga, Ibrahim Halil
    Askin, Lutfu
    Sevimli, Serdar
    NORTHERN CLINICS OF ISTANBUL, 2019, 6 (01) : 40 - 47