Sentinel Lymph Node Biopsy in Breast Cancer: An Analysis of the Maximum Number of Nodes Requiring Excision

被引:7
|
作者
Gill, Jasper [1 ]
Lovegrove, Richard [1 ]
Naessens, Katrien [1 ]
Pursell, Roslyn [1 ]
Cominos, Timothy [1 ]
McCormick, Colin [2 ]
Umeh, Hilary [1 ]
Courtney, Stephen [1 ]
Smith, Brendan [1 ]
机构
[1] Royal Berkshire Hosp, Dept Breast Surg, Reading RG1 5AN, Berks, England
[2] Royal Berkshire Hosp, Dept Pathol, Reading RG1 5AN, Berks, England
来源
BREAST JOURNAL | 2011年 / 17卷 / 01期
关键词
breast neoplasms; isotope count; patent blue dye; sentinel lymph node biopsy; technetium; ROUTINE AXILLARY DISSECTION; MULTICENTER TRIAL; GAMMA-PROBE; PATIENT;
D O I
10.1111/j.1524-4741.2010.01019.x
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Sentinel lymph node biopsy (SNB) is now the standard of care in assessment of patients with clinically staged T1-2, N0 breast cancers. This study investigates whether there is a maximum number of sentinel lymph nodes (SLN) that need to be excised without compromising the false-negative (FN) rate of this procedure. Data were prospectively collected for 319 patients undergoing SNB between February 2001 and December 2006 at our institution. This data were analysed, both in terms of the order of SLN retrieval and relative isotope counts of the SLNs, in order to determine the maximum number of SLNs that need to be retrieved without increasing the FN rate. Furthermore, we investigated the relationship between SLN blue dye concentration and the presence of SLN metastases. The SLN identification rate was 97% with no false-negative cases amongst patients undergoing simultaneous axillary clearance historically during technique validation. In patients with SLN metastases, excision of the first 4 SLNs encountered results in the identification of a metastatic SLN in all cases. Although the majority (86%) of SNB metastases are in the hottest node, the SLN containing the metastasis is in the first 4 hottest nodes in 99% of patients with nodal metastases. The remaining 1% of SLN metastases were identified by blue dye. There was no statistically significant association between the SLN blue dye concentration and the presence of SLN metastases. A policy to remove a maximum of four blue and/or hot SLNs along with any palpably abnormal lymph nodes does not result in an increased false-negative rate of detection of SLN metastases.
引用
收藏
页码:3 / 8
页数:6
相关论文
共 50 条
  • [11] Sentinel lymph node biopsy for breast cancer: Impact of the number of sentinel nodes removed on the false-negative rate
    Wong, SL
    Edwards, MJ
    Chao, C
    Tuttle, TM
    Noyes, RD
    Carlson, DJ
    Cerrito, PB
    McMasters, KM
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2001, 192 (06) : 684 - 689
  • [12] Radlogulded excision of nonpalpable breast cancer with simultaneous sentinel lymph node biopsy
    Peley, G.
    Matrai, Z.
    Renyi-Vamos, F.
    Farkas, E.
    Sinkovics, I.
    Keresztes, S.
    Bidlek, M.
    Szabo, E.
    Orosz, Z.
    Koves, I.
    EJC SUPPLEMENTS, 2004, 2 (03): : 81 - 81
  • [13] Sentinel lymph node biopsy for breast cancer: How many nodes are enough?
    Zakaria, Shaheen
    Degnim, Amy C.
    Kleer, Celina G.
    Diehl, Kathleen A.
    Cimmino, Vincent M.
    Chang, Alfred E.
    Newman, Lisa A.
    Sabel, Michael S.
    JOURNAL OF SURGICAL ONCOLOGY, 2007, 96 (07) : 554 - 559
  • [14] How many nodes are enough in sentinel lymph node biopsy for breast cancer?
    Park, H. Y.
    Lee, Y. H.
    Shin, J. H.
    Hwang, S. O.
    Jung, J. H.
    EJC SUPPLEMENTS, 2008, 6 (07): : 152 - 152
  • [15] Sentinel lymph node biopsy in breast cancer
    Alsaif, Abdulaziz A.
    SAUDI MEDICAL JOURNAL, 2015, 36 (09) : 1053 - 1060
  • [16] The sentinel lymph node biopsy in breast cancer
    Weerts, JM
    Maweja, S
    Tamigneaux, I
    Dallemagne, B
    Jourdan, JL
    Markiewicz, S
    Monami, B
    Wahlen, C
    Lastra, M
    Hénon, V
    Gomez, P
    Lilet, H
    Dwelshauwers, J
    Graas, MP
    Focan, C
    Lipczei, B
    Abraham, F
    Jehaes, C
    ACTA CHIRURGICA BELGICA, 2002, 102 (02) : 110 - 113
  • [17] Sentinel lymph node biopsy in breast cancer
    Sakorafas, GH
    Tsiotou, AG
    AMERICAN SURGEON, 2000, 66 (07) : 667 - 674
  • [18] Sentinel lymph node biopsy in breast cancer
    Dowling, CM
    Hill, ADK
    SURGEON-JOURNAL OF THE ROYAL COLLEGES OF SURGEONS OF EDINBURGH AND IRELAND, 2004, 2 (05): : 273 - 276
  • [19] Sentinel lymph node biopsy and breast cancer
    Noguchi, M
    BRITISH JOURNAL OF SURGERY, 2002, 89 (01) : 21 - 34
  • [20] Sentinel lymph node biopsy for breast cancer: Impact of the number of sentinel nodes removed on the false-negative rate - Reply
    Wong, SL
    McMasters, KM
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2001, 192 (06) : 690 - 691