A thin-film pressure transducer for implantable and intravascular blood pressure sensing
被引:24
|
作者:
Starr, Peter
论文数: 0引用数: 0
h-index: 0
机构:
Univ Texas Hlth Sci Ctr San Antonio, Mail Code 7713,7703 Floyd Curl Dr, San Antonio, TX 78229 USA
Univ Texas San Antonio, MB 2-106,One UTSA Circle, San Antonio, TX 78249 USAUniv Texas Hlth Sci Ctr San Antonio, Mail Code 7713,7703 Floyd Curl Dr, San Antonio, TX 78229 USA
Starr, Peter
[1
,2
]
Bartels, Keith
论文数: 0引用数: 0
h-index: 0
机构:
Univ Texas San Antonio, MB 2-106,One UTSA Circle, San Antonio, TX 78249 USA
Southwest Res Inst, 6220 Culebra Rd, San Antonio, TX 78238 USAUniv Texas Hlth Sci Ctr San Antonio, Mail Code 7713,7703 Floyd Curl Dr, San Antonio, TX 78229 USA
Bartels, Keith
[2
,3
]
Agrawal, C. Mauli
论文数: 0引用数: 0
h-index: 0
机构:
Univ Texas San Antonio, MB 2-106,One UTSA Circle, San Antonio, TX 78249 USAUniv Texas Hlth Sci Ctr San Antonio, Mail Code 7713,7703 Floyd Curl Dr, San Antonio, TX 78229 USA
Agrawal, C. Mauli
[2
]
论文数: 引用数:
h-index:
机构:
Bailey, Steven
[1
,2
,4
]
机构:
[1] Univ Texas Hlth Sci Ctr San Antonio, Mail Code 7713,7703 Floyd Curl Dr, San Antonio, TX 78229 USA
[2] Univ Texas San Antonio, MB 2-106,One UTSA Circle, San Antonio, TX 78249 USA
[3] Southwest Res Inst, 6220 Culebra Rd, San Antonio, TX 78238 USA
[4] Univ Texas Hlth Sci Ctr San Antonio, Mail Code 7872,7703 Floyd Curl Dr, San Antonio, TX 78229 USA
The mm-scale of micromachined pressure transducers limits numerous cardiovascular applications, including implantable pressure sensing. Here, a pressure transducer is presented which adds approximately 15 pm to the surface of an intravascular device, potentially enabling low profile implantable devices with pressure sensing functionality. The capacitive transducer consists of a polyimide diaphragm which can be transferred to an arbitrary substrate, including cardiovascular catheters, stents, or other intravascular devices. The transducer has good static and dynamic characteristics for cardiovascular applications, including pressure sensitivity of 2.5% over 400 mmHg and an estimated flat frequency response of 500 Hz. Additionally, good waveform fidelity was demonstrated in a flow loop relative to a research grade cardiovascular pressure transducer. (C) 2016 Elsevier B.V. All rights reserved.
机构:
Institute of Microsystem Technology, TU Wroclaw, ul.Z. Janiszewskiego 11/17, 50-372 Wroclaw, PolandInstitute of Microsystem Technology, TU Wroclaw, ul.Z. Janiszewskiego 11/17, 50-372 Wroclaw, Poland
Berlicki, T.M.
Osadnik, S.J.
论文数: 0引用数: 0
h-index: 0
机构:
Institute of Microsystem Technology, TU Wroclaw, ul.Z. Janiszewskiego 11/17, 50-372 Wroclaw, PolandInstitute of Microsystem Technology, TU Wroclaw, ul.Z. Janiszewskiego 11/17, 50-372 Wroclaw, Poland
Osadnik, S.J.
Prociów, E.L.
论文数: 0引用数: 0
h-index: 0
机构:
Institute of Microsystem Technology, TU Wroclaw, ul.Z. Janiszewskiego 11/17, 50-372 Wroclaw, PolandInstitute of Microsystem Technology, TU Wroclaw, ul.Z. Janiszewskiego 11/17, 50-372 Wroclaw, Poland