Trace determination of clenbuterol with an MWCNT-Nafion nanocomposite modified electrode

被引:38
|
作者
Guo, Ren-Xia [1 ]
Xu, Qin [1 ]
Wang, De-Yan [1 ]
Hu, Xiao-Ya [1 ]
机构
[1] Yang Zhou Univ, Dept Chem, Jiangsu, Peoples R China
关键词
clenbuterol; carbon nanotubes; Nafion; nanocomposite; electrochemical;
D O I
10.1007/s00604-007-0766-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method for the determination of trace clenbuterol is described. Multi-walled carbon nanotubes (MWCNTs)-Nafion composite was used to modify the glassy carbon electrode (GCE). The modified electrode showed high sensitivity and good selectivity for clenbuterol detection. It offered a linear range of 1.0 x 10(-9)-1.0 x 10(-6) mol . L-1 with a detection limit of 5.0 x 10(-10) mol . L-1 in pH = 1.2 solution. The oxidation mechanism of clenbuterol on the electrode was also investigated.
引用
收藏
页码:265 / 272
页数:8
相关论文
共 50 条
  • [41] DETERMINATION OF ADENINE BY CHRONOPOTENTIOMETRIC STRIPPING ANALYSIS WITH NAFION-MODIFIED ELECTRODE
    JIN, LT
    LIU, SH
    BAI, ZP
    FANG, YZ
    ELECTROANALYSIS, 1993, 5 (07) : 611 - 614
  • [42] Determination of heavy metals in rice (Oryza sativa L.) and soil using AuNP/BiNP/MWCNT/Nafion modified glassy carbon electrode
    Salinas, Tim Aren O.
    Natividad, Michelle T.
    Palisoc, Shirley T.
    HELIYON, 2023, 9 (11)
  • [43] Ethynylferrocene-NiO/MWCNT nanocomposite modified carbon paste electrode as a novel voltammetric sensor for simultaneous determination of glutathione and acetaminophen
    Shahmiri, Mandana Roodbari
    Bahari, Ali
    Karimi-Maleh, Hassan
    Hosseinzadeh, Rahman
    Mirnia, Norodin
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 177 : 70 - 77
  • [44] Voltammetric Determination of o-Phenylenediamine in Industrial Wastewater by An Electrode Modified with Nanocomposite Film of TiO2/Hydroxyapatite/MWCNT
    Li Jun-Hua
    Kuang Dai-Zhi
    Feng Yong-Lan
    Liu Meng-Qin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (12) : 1864 - 1870
  • [45] Preparation and Characterization of MPTMS-Linked MWCNT/Nafion® Nanocomposite Membranes
    Kim, Young Ho
    Lee, Hyun Kyu
    Abu Sayeed, Md
    Park, Younjin
    Gopalan, A. I.
    Lee, Kwang-Pill
    Choi, Sang-June
    JOURNAL OF NANOELECTRONICS AND OPTOELECTRONICS, 2012, 7 (05) : 517 - 521
  • [46] Nafion Coated Silver Amalgam Electrode for Determination of Trace Metals by Anodic Stripping Voltammetry
    Strasunske, Kristina
    Mikkelsen, Oyvind
    Billon, Gabriel
    ELECTROANALYSIS, 2010, 22 (05) : 501 - 507
  • [47] MWCNT-CTAB modified glassy carbon electrode as a sensor for the determination of paracetamol
    Gowda, Jayant I.
    Gunjiganvi, Danavva G.
    Sunagar, Nagaveni B.
    Bhat, Manjushree N.
    Nandibewoor, Sharanappa T.
    RSC ADVANCES, 2015, 5 (61): : 49045 - 49053
  • [48] Pt/MWCNT/GC modified electrode and its application to determination of naphthol isomers
    Wang, Xiaogang
    Wu, Qingsheng
    Ding, Yaping
    Fan, Yajuan
    Tongji Daxue Xuebao/Journal of Tongji University, 2008, 36 (02): : 207 - 211
  • [49] Electrochemical detection of DNA damage induced by clenbuterol at a reduced graphene oxide-Nafion modified glassy carbon electrode
    Lin, Xiaoyun
    Ni, Yongnian
    Pei, Xueying
    Kokot, Serge
    ANALYTICAL METHODS, 2017, 9 (07) : 1105 - 1111
  • [50] Sensitive Electrochemical Determination of Oxcarbazepine using MWCNT Modified Glassy Carbon Electrode
    Ershad, Sohrab
    Sani, Mahnaz Akbari
    Hosseinzadeh, Mehdi
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2023, 15 (08): : 637 - 649