Patients With Syndrome X Have Normal Transmural Myocardial Perfusion and Oxygenation A 3-T Cardiovascular Magnetic Resonance Imaging Study

被引:39
|
作者
Karamitsos, Theodoros D. [1 ]
Arnold, Jayanth R. [1 ]
Pegg, Tammy J. [1 ]
Francis, Jane M. [1 ]
Birks, Jacqueline [2 ]
Jerosch-Herold, Michael [3 ]
Neubauer, Stefan [1 ]
Selvanayagam, Joseph B. [4 ]
机构
[1] Univ Oxford, Ctr Clin Magnet Resonance Res, Dept Cardiovasc Med, Oxford, England
[2] Univ Oxford, Ctr Stat Med, Oxford, England
[3] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[4] Flinders Univ S Australia, Flinders Med Ctr, Dept Cardiovasc Med, Adelaide, SA 5001, Australia
关键词
ischemia; chest pain; microvascular angina; blood flow; oxygen; CARDIAC SYNDROME-X; NORMAL CORONARY ANGIOGRAMS; DOBUTAMINE STRESS ECHOCARDIOGRAPHY; POSITRON-EMISSION-TOMOGRAPHY; CHEST-PAIN; ARTERY-DISEASE; BLOOD-FLOW; ANGINA-PECTORIS; QUANTIFICATION; RESERVE;
D O I
10.1161/CIRCIMAGING.111.969667
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The pathophysiology of chest pain in patients with cardiac syndrome X remains controversial. Advances in perfusion imaging with cardiovascular magnetic resonance (CMR) now enable absolute quantification of regional myocardial blood flow (MBF). Furthermore, blood oxygen level-dependent (BOLD) or oxygenation-sensitive CMR provides the unprecedented capability to assess regional myocardial oxygenation. We hypothesized that the combined assessment of regional perfusion and oxygenation with CMR could clarify whether patients with syndrome X show evidence of myocardial ischemia (reduced perfusion and oxygenation) during vasodilator stress compared with normal volunteers. Methods and Results-Eighteen patients with syndrome X (chest pain, abnormal exercise treadmill test, normal coronary angiogram without other causes of microvascular dysfunction) and 14 controls underwent CMR scanning at 3 T. Myocardial function, scar, perfusion (2-3 short-axis slices), and oxygenation were assessed. Absolute MBF was measured during adenosine stress (140 mu g/kg per minute) and at rest by model-independent deconvolution. For oxygenation, using a T2-prepared BOLD sequence, signal intensity was measured at adenosine stress and rest in the slice matched to the midventricular slice of the perfusion scan. There were no significant differences in MBF at stress (2.35 versus 2.37 mL/min per gram; P=0.91), BOLD signal change (17.3% versus 17.09%; P=0.91), and coronary flow reserve measurements (2.63 versus 2.53; P=0.60) in patients with syndrome X and controls, respectively. Oxygenation and perfusion measurements per coronary territory were also similar between the 2 groups. More patients with syndrome X (17/18 [94%]) developed chest pain during adenosine stress than controls (6/14 [43%]; P=0.004). Conclusions-Patients with syndrome X show greater sensitivity to chest pain compared with controls but no evidence of deoxygenation or hypoperfusion during vasodilatory stress. (Circ Cardiovasc Imaging. 2012;5:194-200.)
引用
收藏
页码:194 / 200
页数:7
相关论文
共 50 条
  • [21] Intraoperative magnetic resonance imaging-guided neurosurgery at 3-T
    Truwit, CL
    Hall, WA
    NEUROSURGERY, 2006, 58 (04) : 338 - 345
  • [22] Clinical safety of 3-T brain magnetic resonance imaging in newborns
    Fumagalli, Monica
    Cinnante, Claudia Maria
    Calloni, Sonia Francesca
    Sorrentino, Gabriele
    Gorla, Ilaria
    Plevani, Laura
    Pesenti, Nicola
    Sirgiovanni, Ida
    Mosca, Fabio
    Triulzi, Fabio
    PEDIATRIC RADIOLOGY, 2018, 48 (07) : 992 - 998
  • [23] The Value of 3-T Magnetic Resonance Imaging in Acute Transverse Myelitis
    Austin, Erica
    Betz, Bradford
    Arndt, Daniel
    PEDIATRIC NEUROLOGY, 2014, 51 (06) : 860 - 861
  • [24] Accelerated, high spatial resolution cardiovascular magnetic resonance myocardial perfusion imaging
    Motwani, Manish
    Lockie, Timothy
    Greenwood, John P.
    Plein, Sven
    JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (05) : 952 - 958
  • [25] Quantitative myocardial perfusion imaging by cardiovascular magnetic resonance and positron emission tomography
    K. Bratis
    I. Mahmoud
    A. Chiribiri
    E. Nagel
    Journal of Nuclear Cardiology, 2013, 20 : 860 - 870
  • [26] Quantitative myocardial perfusion imaging by cardiovascular magnetic resonance and positron emission tomography
    Bratis, K.
    Mahmoud, I.
    Chiribiri, A.
    Nagel, E.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (05) : 860 - 870
  • [27] Accelerated, high spatial resolution cardiovascular magnetic resonance myocardial perfusion imaging
    Manish Motwani
    Timothy Lockie
    John P. Greenwood
    Sven Plein
    Journal of Nuclear Cardiology, 2011, 18 : 952 - 958
  • [28] SYSTOLIC VS DIASTOLIC ACQUISITION IN CARDIOVASCULAR MAGNETIC RESONANCE MYOCARDIAL PERFUSION IMAGING
    Motwani, M.
    Fairbairn, T. A.
    Larghat, A.
    Mather, A. N.
    Biglands, J. D.
    Radjenovic, A.
    Greenwood, J. P.
    Plein, S.
    HEART, 2012, 98 : A48 - A49
  • [29] Myocardial Perfusion Imaging by Cardiovascular Magnetic Resonance: Research Progress and Current Implementation
    Li, Xue-Ming
    Jiang, Li
    Min, Chen-Yan
    Yan, Wei-Feng
    Shen, Meng-Ting
    Liu, Xiao-Jing
    Guo, Ying-Kun
    Yang, Zhi-Gang
    CURRENT PROBLEMS IN CARDIOLOGY, 2023, 48 (06)
  • [30] Imaging collateral circulation - Magnetic resonance angiography and perfusion magnetic resonance imaging at 3 T
    Lee, CEC
    Ng, HBI
    Yip, CW
    Lim, CCT
    ARCHIVES OF NEUROLOGY, 2005, 62 (03) : 492 - 493