Development of a Multisensory Wearable System for Monitoring Cigarette Smoking Behavior in Free-Living Conditions

被引:32
|
作者
Imtiaz, Masudul Haider [1 ]
Ramos-Garcia, Raul I. [1 ]
Senyurek, Volkan Yusuf [1 ]
Tiffany, Stephen [2 ]
Sazonov, Edward [1 ]
机构
[1] Univ Alabama, Dept Elect & Comp Engn, Tuscaloosa, AL 35487 USA
[2] SUNY Buffalo, Dept Psychol, Buffalo, NY 14260 USA
来源
ELECTRONICS | 2017年 / 6卷 / 04期
基金
美国国家卫生研究院;
关键词
accelerometer; bio-impedance; cigarette smoking; ECG; GPS; PACT; RIP; INHALATION;
D O I
10.3390/electronics6040104
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents the development and validation of a novel multi-sensory wearable system (Personal Automatic Cigarette Tracker v2 or PACT2.0) for monitoring of cigarette smoking in free-living conditions. The contributions of the PACT2.0 system are: (1) the implementation of a complete sensor suite for monitoring of all major behavioral manifestations of cigarette smoking (lighting events, hand-to-mouth gestures, and smoke inhalations); (2) a miniaturization of the sensor hardware to enable its applicability in naturalistic settings; and (3) an introduction of new sensor modalities that may provide additional insight into smoking behavior e.g., Global Positioning System (GPS), pedometer and Electrocardiogram(ECG) or provide an easy-to-use alternative (e.g., bio-impedance respiration sensor) to traditional sensors. PACT2.0 consists of three custom-built devices: an instrumented lighter, a hand module, and a chest module. The instrumented lighter is capable of recording the time and duration of all lighting events. The hand module integrates Inertial Measurement Unit (IMU) and a Radio Frequency (RF) transmitter to track the hand-to-mouth gestures. The module also operates as a pedometer. The chest module monitors the breathing (smoke inhalation) patterns (inductive and bio-impedance respiratory sensors), cardiac activity (ECG sensor), chest movement (three-axis accelerometer), hand-to-mouth proximity (RF receiver), and captures the geo-position of the subject (GPS receiver). The accuracy of PACT2.0 sensors was evaluated in bench tests and laboratory experiments. Use of PACT2.0 for data collection in the community was validated in a 24 h study on 40 smokers. Of 943 h of recorded data, 98.6% of the data was found usable for computer analysis. The recorded information included 549 lighting events, 522/504 consumed cigarettes (from lighter data/self-registered data, respectively), 20,158/22,207 hand-to-mouth gestures (from hand IMU/proximity sensor, respectively) and 114,217/112,175 breaths (from the respiratory inductive plethysmograph (RIP)/bio-impedance sensor, respectively). The proposed system scored 8.3 +/- 0.31 out of 10 on a post-study acceptability survey. The results suggest that PACT2.0 presents a reliable platform for studying of smoking behavior at the community level.
引用
收藏
页码:1 / 21
页数:21
相关论文
共 50 条
  • [21] Intake monitoring in free-living conditions: Overview and lessons we have learned
    Diou, Christos
    Kyritsis, Konstantinos
    Papapanagiotou, Vasileios
    Sarafis, Ioannis
    APPETITE, 2022, 176
  • [22] The utility of wearable devices in assessing ambulatory impairments of people with multiple sclerosis in free-living conditions
    Sun, Shaoxiong
    Folarin, Amos A.
    Zhang, Yuezhou
    Cummins, Nicholas
    Liu, Shuo
    Stewart, Callum
    Ranjan, Yatharth
    Rashid, Zulqarnain
    Conde, Pauline
    Laiou, Petroula
    Sankesara, Heet
    Dalla Costa, Gloria
    Leocani, Letizia
    Sorensen, Per Soelberg
    Magyari, Melinda
    Isabel Guerrero, Ana
    Zabalza, Ana
    Vairavan, Srinivasan
    Bailon, Raquel
    Simblett, Sara
    Myin-Germeys, Inez
    Rintala, Aki
    Wykes, Til
    Narayan, Vaibhav A.
    Hotopf, Matthew
    Comi, Giancarlo
    Dobson, Richard J. B.
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2022, 227
  • [23] An Interpretable Model for Predicting Preoperative Cardiorespiratory Fitness Using Wearable Data in Free-Living Conditions
    Hussain, Iqram
    Zeepvat, Julianna
    Reid, Cary
    Czaja, Sara
    Pryor, Kane
    Boyer, Richard
    CIRCULATION, 2024, 150
  • [24] Estimation of Gait Parameters in Huntingtons Disease Using Wearable Sensors in the Clinic and Free-living Conditions
    Lozano-Garcia, Manuel
    Doheny, Emer P.
    Mann, Elliot
    Morgan-Jones, Philippa
    Drew, Cheney
    Busse-Morris, Monica
    Lowery, Madeleine M.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2024, 32 : 2239 - 2249
  • [25] DEVELOPMENT OF SOCIOSEXUAL BEHAVIOR IN FREE-LIVING BABOONS, PAPIO-ANUBIS
    OWENS, NW
    BEHAVIOUR, 1976, 57 : 241 - &
  • [26] Cardiorespiratory fitness estimation in free-living using wearable sensors
    Altini, Marco
    Casale, Pierluigi
    Penders, Julien
    Amft, Oliver
    ARTIFICIAL INTELLIGENCE IN MEDICINE, 2016, 68 : 37 - 46
  • [27] Ambulatory monitoring of cumulative free-living activity
    Moy, ML
    Mentzer, SJ
    Reilly, JJ
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2003, 22 (03): : 89 - 95
  • [28] THE MATING SYSTEM OF FREE-LIVING EMUS
    CODDINGTON, CL
    COCKBURN, A
    AUSTRALIAN JOURNAL OF ZOOLOGY, 1995, 43 (04) : 365 - 372
  • [29] Using Wearable Sensors to Capture the Synchrony of Circadian Rhythms Across Physiological Processes in Free-living Conditions
    Thornton, Christopher
    Smith, Billy C.
    Besne, Guillermo M.
    Wang, Yujiang
    2024 IEEE BIOSENSORS CONFERENCE, BIOSENSORS 2024, 2024,
  • [30] Development of free-living stages of Strongyloides ratti under different temperature conditions
    Sakamoto, Maki
    Uga, Shoji
    PARASITOLOGY RESEARCH, 2013, 112 (12) : 4009 - 4013