Augmented Reality during Open Liver Surgery Using a Markerless Non-rigid Registration System

被引:50
|
作者
Golse, Nicolas [1 ,2 ,3 ,4 ,5 ]
Petit, Antoine [5 ]
Lewin, Maite [6 ]
Vibert, Eric [1 ,2 ,3 ,4 ]
Cotin, Stephane [5 ]
机构
[1] Hop Paul Brousse, AP HP, Dept Surg, Ctr Hepatobiliaire, 12 Ave Paul Vaillant Couturier, F-94804 Villejuif, France
[2] DHU Hepatinov, F-94800 Villejuif, France
[3] INSERM, Unit 1193, F-94800 Villejuif, France
[4] Univ Paris Sud, UMR S 1193, F-94800 Villejuif, France
[5] INRIA, Strasbourg, France
[6] Hop Paul Brousse, AP HP, Dept Radiol, Ctr Hepatobiliaire, F-94800 Villejuif, France
关键词
Augmented reality; Liver resection; Non-rigid registration; RGB-D camera; LESIONS;
D O I
10.1007/s11605-020-04519-4
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Introduction Intraoperative navigation during liver resection remains difficult and requires high radiologic skills because liver anatomy is complex and patient-specific. Augmented reality (AR) during open liver surgery could be helpful to guide hepatectomies and optimize resection margins but faces many challenges when large parenchymal deformations take place. We aimed to experiment a new vision-based AR to assess its clinical feasibility and anatomical accuracy. Patients and Methods Based on preoperative CT scan 3-D segmentations, we applied a non-rigid registration method, integrating a physics-based elastic model of the liver, computed in real time using an efficient finite element method. To fit the actual deformations, the model was driven by data provided by a single RGB-D camera. Five livers were considered in this experiment. In vivo AR was performed during hepatectomy (n = 4), with manual handling of the livers resulting in large realistic deformations. Ex vivo experiment (n = 1) consisted in repeated CT scans of explanted whole organ carrying internal metallic landmarks, in fixed deformations, and allowed us to analyze our estimated deformations and quantify spatial errors. Results In vivo AR tests were successfully achieved in all patients with a fast and agile setup installation (< 10 min) and real-time overlay of the virtual anatomy onto the surgical field displayed on an external screen. In addition, an ex vivo quantification demonstrated a 7.9 mm root mean square error for the registration of internal landmarks. Conclusion These first experiments of a markerless AR provided promising results, requiring very little equipment and setup time, yet providing real-time AR with satisfactory 3D accuracy. These results must be confirmed in a larger prospective study to definitively assess the impact of such minimally invasive technology on pathological margins and oncological outcomes.
引用
收藏
页码:662 / 671
页数:10
相关论文
共 50 条
  • [41] Vision-based markerless registration using stereo vision and an augmented reality surgical navigation system: a pilot study
    Hideyuki Suenaga
    Huy Hoang Tran
    Hongen Liao
    Ken Masamune
    Takeyoshi Dohi
    Kazuto Hoshi
    Tsuyoshi Takato
    BMC Medical Imaging, 15
  • [42] Vision-based markerless registration using stereo vision and an augmented reality surgical navigation system: a pilot study
    Suenaga, Hideyuki
    Tran, Huy Hoang
    Liao, Hongen
    Masamune, Ken
    Dohi, Takeyoshi
    Hoshi, Kazuto
    Takato, Tsuyoshi
    BMC MEDICAL IMAGING, 2015, 15
  • [43] SEMIAUTOMATIC NON-RIGID 3-D IMAGE REGISTRATION FOR MR-GUIDED LIVER CANCER SURGERY
    Chen, Yen-Wei
    Tsubokawa, Katsumi
    Xu, Rui
    Morikawa, Shigehiro
    Kurumi, Yoshimasa
    2008 15TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-5, 2008, : 1800 - 1803
  • [44] Incorporating rigid structures in non-rigid registration using triangular B-splines
    Wang, KX
    He, Y
    Qin, H
    VARIATIONAL, GEOMETRIC, AND LEVEL SET METHODS IN COMPUTER VISION, PROCEEDINGS, 2005, 3752 : 235 - 246
  • [45] Non-rigid registration of breast MR images using mutual information
    Rueckert, D
    Hayes, C
    Studholme, C
    Summers, P
    Leach, M
    Hawkes, DJ
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI'98, 1998, 1496 : 1144 - 1152
  • [46] Non-rigid image registration using a statistical spline deformation model
    Loeckx, D
    Maes, F
    Vandermeulen, D
    Suetens, P
    INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 2003, 2732 : 463 - 474
  • [47] Registration of non-rigid medical images using an elastic spatial transformation
    Wirth, MA
    Choi, C
    Jennings, A
    SCIA '97 - PROCEEDINGS OF THE 10TH SCANDINAVIAN CONFERENCE ON IMAGE ANALYSIS, VOLS 1 AND 2, 1997, : 675 - 675
  • [48] Non-rigid registration of breast surfaces using the laplace and diffusion equations
    Rowena E Ong
    Jao J Ou
    Michael I Miga
    BioMedical Engineering OnLine, 9
  • [49] Analysis Of Cerebral Ischemia MRI Images Using Non-rigid Registration
    Wang, Rui
    Suo, Shiteng
    Wang, Dan
    Li, Yuehua
    Zhang, Su
    PROCEEDINGS OF 2012 IEEE 11TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING (ICSP) VOLS 1-3, 2012, : 976 - +
  • [50] Optimization of Non-rigid Demons Registration Using Cuckoo Search Algorithm
    Sayan Chakraborty
    Nilanjan Dey
    Sourav Samanta
    Amira S. Ashour
    C. Barna
    M. M. Balas
    Cognitive Computation, 2017, 9 : 817 - 826