Fat-suppressed three-dimensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee: Comparison with standard MR imaging and arthroscopy

被引:321
|
作者
Disler, DG [1 ]
McCauley, TR [1 ]
Kelman, CG [1 ]
Fuchs, MD [1 ]
Ratner, LM [1 ]
Wirth, CR [1 ]
Hospodar, PP [1 ]
机构
[1] ALBANY MED COLL, DEPT SURG, DIV ORTHOPED SURG, ALBANY, NY 12208 USA
关键词
D O I
10.2214/ajr.167.1.8659356
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The sensitivity of fat-suppressed three-dimensional spoiled gradient-echo (SPGR) images was compared with that of standard MR images for detecting hyaline cartilage defects of the knee, using arthroscopy as the standard of reference. SUBJECTS AND METHODS. We assessed 114 consecutive patients for hyaline cartilage defects of the knee with both standard MR imaging sequences and a sagittal fat suppressed three-dimensional SPGR sequence. Of these patients, 48 with meniscal or ligament injury, or persistent symptoms, underwent subsequent arthroscopy. The standard MR images and SPGR images of these 48 patients were then retrospectively analyzed for articular defects in a blinded fashion by two independent observers, Sensitivity, specificity, and intraobserver and interobserver agreement were determined for the different imaging techniques. RESULTS. One fourth of the patients who went on to arthroscopy were shown to have isolated hyaline cartilage lesions that were clinically confused with meniscal tears and that were missed on the standard MR images. When looking at all surfaces combined for each reader, the SPGR imaging sequence had a significantly higher sensitivity than the standard MR imaging sequences for detecting hyaline cartilage defects (75-85% versus 29-38%, p <.001 for each comparison). When looking at individual surfaces for each reader, significant differences in sensitivity were shown for each surface except the trochlear and lateral tibial surfaces. We found no difference in specificity (97% versus 97%, p >.99). We also found that combined evaluation of standard MR and SPGR images gave no added diagnostic advantage (sensitivity, 86%; specificity, 97%; p >.42). Except for the lateral tibial surface, the study achieved excellent reproducibility among readings and between readers. CONCLUSION. Fat-suppressed three-dimensional SPGR imaging is more sensitive than standard MR imaging for the detection of hyaline cartilage defects of the knee.
引用
收藏
页码:127 / 132
页数:6
相关论文
共 50 条
  • [31] Fat-suppressed 3D-T1-weighted-echo planar imaging: comparison with fat-suppressed 3D-T1-weighted-gradient echo in imaging the cartilage of the knee
    Karantanas, AH
    Zibis, AH
    Kitsoulis, P
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (03) : 159 - 165
  • [32] Contrast-enhanced three-dimensional fast spoiled gradient-echo renal MR imaging: Evaluation of vascular and nonvascular disease - Commentary
    Frager, DH
    RADIOGRAPHICS, 2000, 20 (05) : 1353 - 1354
  • [33] Quantification of articular cartilage in the knee with three-dimensional MR imaging
    Dupuy, DE
    Spillane, RM
    Rosol, MS
    Rosenthal, DI
    Palmer, WE
    Burke, DW
    Rosenberg, AE
    ACADEMIC RADIOLOGY, 1996, 3 (11) : 919 - 924
  • [34] Three-dimensional gradient-echo imaging for percutaneous MR-guided laser therapy of liver metastasis
    Puls, Ralf
    Stroszczynski, Christian
    Rosenberg, Christian
    Kuehn, Jens-Peter
    Hegenscheid, Katrin
    Speck, Ulrich
    Stier, Albrecht
    Hosten, Norbert
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (06) : 1174 - 1178
  • [35] Evaluation of Knee Cartilage Defects with an Add Up Sequence of Three-dimensional Spoiled Gradient-recalled Echo Fat-saturated to Routine Magnetic Resonance Imaging of Knee
    Ahmed, B. Ashraf
    Pitchai, Alex Daniel Prabhu Arul
    Farook, Abdul Khader
    Kandru, Lakshmi Aparna
    Elangovan, Vivek
    Farook, Abubacker Sulaiman
    INTERNATIONAL JOURNAL OF SCIENTIFIC STUDY, 2016, 4 (05) : 114 - 116
  • [36] RENAL-CANCER STAGING - COMPARISON OF CONTRAST-ENHANCED CT AND GADOLINIUM-ENHANCED FAT-SUPPRESSED SPIN-ECHO AND GRADIENT-ECHO MR-IMAGING
    SEMELKA, RC
    SHOENUT, JP
    MAGRO, CM
    KROEKER, MA
    MACMAHON, R
    GREENBERG, HM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (04): : 597 - 602
  • [37] MR-IMAGING OF THE KNEE IN THE SAGITTAL PROJECTION - COMPARISON OF 3-DIMENSIONAL GRADIENT-ECHO AND SPIN-ECHO SEQUENCES
    REEDER, JD
    MATZ, SO
    BECKER, L
    ANDELMAN, SM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (03) : 537 - 540
  • [38] Three-Dimensional Fast Spin-Echo Imaging without Fat Suppression of the Knee: Diagnostic Accuracy Comparison to Fat-Suppressed Imaging on 1.5T MRI
    Cho, Hee Woo
    Suh, Jin-Suck
    Park, Jin-Oh
    Kim, Hyoung-Sik
    Chung, Soo Yoon
    Lee, Young Han
    Hahn, Seok
    YONSEI MEDICAL JOURNAL, 2017, 58 (06) : 1186 - 1194
  • [39] Fat-suppressed 3D spoiled gradient-echo MRI and MDCT arthrography of articular cartilage in patients with hip dysplasia
    Nishii, T
    Tanaka, H
    Nakanishi, K
    Sugano, N
    Miki, H
    Yoshikawa, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (02) : 379 - 385
  • [40] Cervical spondylosis: Three-dimensional gradient-echo MR with magnetization transfer
    Melhem, ER
    Benson, ML
    Beauchamp, NJ
    Lee, RR
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1996, 17 (04) : 705 - 711