Evaluating the effectiveness of a novel atomized liquid needle-free transdermal delivery system

被引:5
|
作者
Huang, Yi-Huei [1 ]
Hu, Chieh-Shen [1 ]
Ke, Yi-Jhen [2 ]
Chiang, Chiao-Hsi [3 ]
Hong, Po-Da [1 ]
Yeh, Ming-Kung [3 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Grad Inst Appl Sci & Technol, Biomed Engn Program, Taipei, Taiwan
[2] Natl Taiwan Univ Sci & Technol, Grad Inst Biomed Engn, Taipei, Taiwan
[3] Natl Def Med Ctr, Sch Pharm, Taipei, Taiwan
关键词
Diclofenac sodium; Jet injection; Microneedles; Needle-free; Transdermal delivery; FREE JET INJECTION; INFLUENZA VACCINE; POLYMERIC NANOPARTICLES; DRUG-DELIVERY; DNA DELIVERY; EAR SKIN; IMMUNOGENICITY; IMMUNIZATION; HEPATITIS; CHILDREN;
D O I
10.1007/s13346-017-0382-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Needle-free jet injections constitute a crucial method for drug delivery. A novel liquid drug delivery system has been proposed recently, in which pressure atomizes liquid before delivering that atomized liquid to the patient's body; however, the mechanism and efficiency of the system are unclear. This study explored the shot delivery pressure, penetration depth, and cumulative amount of permeation of this system. This system was used to deliver 0.5% (w/v) methylene blue to agarose phantoms at various shot delivery pressures. Shots of methylene blue were also delivered to porcine skin samples at different shot delivery frequencies for light microscopy evaluation. A commercial microneedle array was used for comparing the effectiveness of the skin penetration depths. The array was gently stamped against porcine skin; methylene blue was subsequently applied to the area for different time points, followed by microscopic observations. In vitro skin penetration was tested using static Franz diffusion cells over 8 h. Finally, the feasibility of the system's clinical application was evaluated by analyzing the local analgesic effect in a heat nociceptive animal model. The penetration depths created using 100 shots at 100 psi were similar to those created using the commercial microneedle array for 2 h. Thermal stimulation responses showed that 15 min after diclofenac sodium was delivered by the system, heat nociception was significantly attenuated for 60 min. Our study presents a novel delivery system that may be useful for future clinical applications.
引用
收藏
页码:609 / 616
页数:8
相关论文
共 50 条
  • [31] Improved DNA Vaccine Delivery with Needle-Free Injection Systems
    Ledesma-Feliciano, Carmen
    Chapman, Ros
    Hooper, Jay W.
    Elma, Kira
    Zehrung, Darin
    Brennan, Miles B.
    Spiegel, Erin K.
    VACCINES, 2023, 11 (02)
  • [32] Needle-free injection devices for targeted oral delivery of macromolecules
    Fang, Zhonglin
    Zhang, Zhuohao
    Shang, Luoran
    Science Bulletin, 2025, 70 (07) : 1010 - 1012
  • [33] Delivery of intracavernosal therapies using needle-free injection devices
    O'Kane, D.
    Gibson, L.
    du Plessis, J.
    Davidson, A.
    Bolton, D.
    Lawrentschuk, N.
    INTERNATIONAL JOURNAL OF IMPOTENCE RESEARCH, 2017, 29 (06) : 225 - 228
  • [34] Delivery of intracavernosal therapies using needle-free injection devices
    D O'Kane
    L Gibson
    J du Plessis
    A Davidson
    D Bolton
    N Lawrentschuk
    International Journal of Impotence Research, 2017, 29 : 225 - 228
  • [35] Rapid and precise delivery of cells in the urethral sphincter complex by a novel needle-free waterjet technology
    Linzenbold, Walter
    Jaeger, Luise
    Stoll, Hartmut
    Abruzzese, Tanja
    Harland, Niklas
    Beziere, Nicolas
    Fech, Andreas
    Enderle, Markus
    Amend, Bastian
    Stenzl, Arnulf
    Aicher, Wilhelm K.
    BJU INTERNATIONAL, 2021, 127 (04) : 463 - 472
  • [36] Needle-free small-volume Liquid Injection System Powered by a Rotary Actuator
    Zhang, Aoyu
    Hogan, N. Catherine
    Hunter, Ian W.
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 292 - 295
  • [37] Needle-free liquid injection system powered by voice-coil linear actuator
    Chen K.
    Yang F.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2011, 47 (09): : 151 - 156
  • [38] A needle-free approach for topical immunization:: Antigen delivery via vesicular carrier system(s)
    Mahor, Sunil
    Gupta, Prem N.
    Rawat, Amit
    Vyas, Suresh P.
    CURRENT MEDICINAL CHEMISTRY, 2007, 14 (27) : 2898 - 2910
  • [39] Iontophoresis: A needle-free, electrical system of local anesthesia delivery for pediatric surgical office procedures
    DeCou, JM
    Abrams, RS
    Hammond, JH
    Lowder, LR
    Gauderer, MWL
    JOURNAL OF PEDIATRIC SURGERY, 1999, 34 (06) : 946 - 949
  • [40] Inertial liquid loading on the nozzle of a needle-free injection device
    Symons, DD
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2004, 218 (02) : 233 - 240