Relationship between shear modulus and passive tension of the posterior shoulder capsule using ultrasound shear wave elastography: A cadaveric study

被引:12
|
作者
Iida, Naoya [1 ,2 ]
Taniguchi, Keigo [3 ]
Watanabe, Kota [3 ]
Miyamoto, Hiroki [1 ]
Taniguchi, Tatsuya [1 ]
Fujimiya, Mineko [4 ]
Katayose, Masaki [3 ]
机构
[1] Sapporo Med Univ, Grad Sch Hlth Sci, Sapporo, Hokkaido, Japan
[2] Sapporo Med Univ Hosp, Dept Rehabil, Sapporo, Hokkaido, Japan
[3] Sapporo Med Univ, Sch Hlth Sci, Div Phys Therapy 2, Sapporo, Hokkaido, Japan
[4] Sapporo Med Univ, Sch Med, Div Anat 2, Sapporo, Hokkaido, Japan
关键词
Elasticity; Stiffness; Posterior shoulder tightness; Stretching; GLENOHUMERAL JOINT; ELASTIC-MODULUS; MECHANICAL-PROPERTIES; ROTATION; MOTION; STRAIN; RANGE; HIP;
D O I
10.1016/j.jbiomech.2019.109498
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Although shear wave elastography (SWE) has been used to indirectly measure passive tension in muscle tissues, it is unknown whether SWE can adequately evaluate passive tension in capsule tissues. This study investigated the relationship between the shear modulus and passive tension in the posterior shoulder capsule using SWE. Ten posterior middle and ten posterior inferior shoulder capsules were dissected from ten fresh-frozen cadavers; humeral head-capsule-glenoid specimens were created from each capsule. The humeral head and glenoid were immobilized with clamps in a custom-built device. Loads (0-400 g, in 25-g increments) were applied to each capsule via a pulley system; elasticity was simultaneously measured using SWE. The elasticity-load relationship of each tested capsule was analyzed by fitting a least-squares regression line to the data. Elasticity change due to creep or hysteresis effects was evaluated by comparing the elastic modulus for a 100-g load during and after the stepwise application of the loads. The observed relationship between the shear modulus and passive capsule tension was highly linear for all twenty tested capsules (p < 0.01). The mean coefficient of determination was 0.882 +/- 0.075 and 0.901 +/- 0.050 for the posterior middle and posterior inferior capsules, respectively. There was no difference in the shear modulus between the two 100-g load assessments for both the posterior middle (p = 0.205) and posterior inferior capsules (p = 0.161). Thus, SWE is a valid and useful method for indirectly evaluating the change in the passive tension under loading in specific posterior shoulder capsule. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Quantifying passive muscle stiffness in children with and without cerebral palsy using ultrasound shear wave elastography
    Brandenburg, Joline E.
    Eby, Sarah F.
    Song, Pengfei
    Kingsley-Berg, Shirley
    Bamlet, William
    Sieck, Gary C.
    An, Kai-Nan
    DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 2016, 58 (12): : 1288 - 1294
  • [32] Anterior deltoid muscle tension quantified with shear wave ultrasound elastography correlates with pain level after reverse shoulder arthroplasty
    Schmalzl, Jonas
    Fenwick, Annabel
    Reichel, Thomas
    Schmitz, Benedikt
    Jordan, Martin
    Meffert, Rainer
    Plumhoff, Piet
    Boehm, Dirk
    Gilbert, Fabian
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2022, 32 (02): : 333 - 339
  • [33] Anterior deltoid muscle tension quantified with shear wave ultrasound elastography correlates with pain level after reverse shoulder arthroplasty
    Jonas Schmalzl
    Annabel Fenwick
    Thomas Reichel
    Benedikt Schmitz
    Martin Jordan
    Rainer Meffert
    Piet Plumhoff
    Dirk Boehm
    Fabian Gilbert
    European Journal of Orthopaedic Surgery & Traumatology, 2022, 32 : 333 - 339
  • [34] Age-related change in shear elastic modulus of the thoracolumbar multifidus muscle in healthy Beagle dogs using ultrasound shear wave elastography
    Tokunaga, Akari
    Shimizu, Miki
    JOURNAL OF VETERINARY SCIENCE, 2021, 22 (01) : 1 - 13
  • [35] Supersonic Shear Imaging Elastography in Skeletal Muscles: Relationship Between In Vivo and Synthetic Fiber Angles and Shear Modulus
    Lima, Kelly
    Rouffaud, Remi
    Pereira, Wagner
    Oliveira, Liliam F.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (01) : 81 - 90
  • [36] The Relationship between Placental Shear Wave Elastography and Fetal Weight-A Prospective Study
    Cavanagh, Erika
    Crawford, Kylie
    Hong, Jesrine Gek Shan
    Fontanarosa, Davide
    Edwards, Christopher
    Wille, Marie-Luise
    Hong, Jennifer
    Clifton, Vicki L.
    Kumar, Sailesh
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (15)
  • [37] Glenohumeral joint capsular tissue tension loading correlates moderately with shear wave elastography: a cadaveric investigation
    Nichols, Charles W.
    Brismee, Jean-Michel
    Hooper, Troy L.
    Bertrand-Grenier, Antony
    Gilbert, Kerry K.
    St-Pierre, Marc-Olivier
    Kapila, Jeegisha
    Sobczak, Stephane
    ULTRASONOGRAPHY, 2020, 39 (02) : 114 - 120
  • [38] Quantifying extensibility of rotator cuff muscle with tendon rupture using shear wave elastography: A cadaveric study
    Hatta, Taku
    Giambini, Hugo
    Itoigawa, Yoshiaki
    Hooke, Alexander W.
    Sperling, John W.
    Steinmann, Scott P.
    Itoi, Eiji
    An, Kai-Nan
    JOURNAL OF BIOMECHANICS, 2017, 61 : 131 - 136
  • [39] Relationship Between the Changes of Tendon Elastic Moduli With Ultrasound Shear Wave Elastography and Mechanical Compression Test
    Iida, Naoya
    Thoreson, Andrew R.
    Reisdorf, Ramona L.
    Tsukamoto, Ichiro
    El Hor, Hicham
    Zhao, Chunfeng
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (04): : 586 - 591
  • [40] Reconstruction of Viscosity Maps in Elastography using Ultrasound Shear Wave Attenuation
    Bhatt, Manish
    Moussu, Marine A. C.
    Chayer, Boris
    Destrempes, Francois
    Gesnik, Marc
    Allard, Louise
    Tang, An
    Cloutier, Guy
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 115 - 118