摘要
Rapidly depleting resources of surface water necessitate the exploration of groundwater reservoirs to cope with the water demand in Lahore and its periphery. For this purpose, a study was conducted to investigate groundwater depth, water quality, and subsurface lithology through Geo-electrical Resistivity Survey (ERS). Vertical electrical soundings (VES) at six (06) stations in the city of Lahore were performed using Schlumberger array. Apparent resistivity values were recorded at surface and processed with a computer software IPI2win to assess groundwater depth, quality, and subsurface formations. The VES resulted that the study area comprises of three layers. Top layer was determined as fill up to depth of 2 m followed by an unsaturated alluvium up to depth of 40 m, and the bottom layer was saturated alluvium up to the study depth of 100 m. The average water table depth was appeared to be at 39 m below the ground surface. The computed groundwater depths were also compared with the previous studies conducted in the proximity by different agencies in the past using destructive techniques and showed close resemblance. The study also shows that the groundwater up to depth of 100 m was having excess amount of total dissolved solids and was not drinkable as per quality standards set by the World Health Organization.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Coal quality and occurrence in areas of western Khyber Pakhtunkhwa, Pakistan, using GPR and electrical resistivity methods
    Mohibullah Khan
    Sarfraz Khan
    Liaqat Ali
    Umair Bin Nisar
    Journal of Earth System Science, 131
  • [32] Quality control of fresh deep mixing soil using electrical resistivity method
    Japan Home Shield Co., Ltd., Japan
    不详
    不详
    不详
    AIJ J. Technol. Des., 48 (545-550):
  • [33] Assessment of Leachate Infiltration From Piyungan Landfill Using Electrical Resistivity Method
    Parhusipa, Jaingot Anggiat
    Harijoko, Agung
    Putra, Doni Prakasa Eka
    Suryanto, Wiwit
    1ST INTERNATIONAL GEO-ELECTROMAGNETIC WORKSHOP (GEO-EM 2017), 2017, 1861
  • [34] Assessment of submarine groundwater discharge in the intertidal zone of Laizhou Bay, China, using electrical resistivity tomography
    Fu, Tengfei
    Zhang, Yufeng
    Xu, Xingyong
    Su, Qiao
    Chen, Guangquan
    Guo, Xiujun
    ESTUARINE COASTAL AND SHELF SCIENCE, 2020, 245
  • [35] Groundwater-recharge estimation using a surface electrical resistivity method in the Himalayan foothill region, India
    Israil, M
    al-hadithi, M
    Singhal, DC
    Kumar, B
    HYDROGEOLOGY JOURNAL, 2006, 14 (1-2) : 44 - 50
  • [36] Detection of solid waste dumpsite-induced groundwater contamination leachate using electrical resistivity method
    Mathiazhagan, M.
    Selvakumar, T.
    Ganesan, Madhavi
    GROUNDWATER MODELING AND MANAGEMENT UNDER UNCERTAINTY, 2012, : 307 - 312
  • [37] Groundwater-recharge estimation using a surface electrical resistivity method in the Himalayan foothill region, India
    M. Israil
    Mufid al-hadithi
    D. C. Singhal
    Bhism Kumar
    Hydrogeology Journal, 2006, 14 : 44 - 50
  • [38] Groundwater aquifer detection using the electrical resistivity method at Ito Campus, Kyushu University (Fukuoka, Japan)
    Wahab, Shafiqullah
    Saibi, Hakim
    Mizunaga, Hideki
    GEOSCIENCE LETTERS, 2021, 8 (01)
  • [39] Groundwater potential zones delineation using geo-electrical resistivity method and GIS for Coimbatore, India
    Shantharam, Y.
    Elangovan, K.
    INDIAN JOURNAL OF GEO-MARINE SCIENCES, 2018, 47 (05) : 1088 - 1095
  • [40] Groundwater aquifer detection using the electrical resistivity method at Ito Campus, Kyushu University (Fukuoka, Japan)
    Shafiqullah Wahab
    Hakim Saibi
    Hideki Mizunaga
    Geoscience Letters, 8