摘要
We investigated a high-brightness field-emission flat-panel lighting source based on a carbon-nanotube cold cathode. A flat-panel lighting source with a triode structure was fabricated. The maximum luminance of 110 000 cd/m(2) was achieved at a green wavelength at the phosphor screen voltage of 10 kV and a current density of 200 mu A/cm(2). The YAGG:Tb phosphor property under high current density is also discussed. (c) 2008 American Vacuum Society.
引用
收藏
页码:106 / 109
页数:4
相关论文
共 50 条
  • [41] Using a flat-panel detector in high resolution cone beam CT for dental imaging
    Baba, R
    Ueda, K
    Okabe, M
    DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (05) : 285 - 290
  • [42] Flat panel display prototype using gated carbon nanotube field emitters
    Wang, QH
    Yan, M
    Chang, RPH
    APPLIED PHYSICS LETTERS, 2001, 78 (09) : 1294 - 1296
  • [43] Pulsed voltage driving enhanced electron emission in ZnO nanowire cold cathode flat-panel X-ray source
    Zhao, Yangyang
    Chen, Yicong
    Zhang, Guofu
    Huang, Deyi
    Zhan, Runze
    Deng, Shaozhi
    Xu, Ningsheng
    Chen, Jun
    VACUUM, 2022, 199
  • [44] Very High Field-Emission Current From a Carbon-Nanotube Cathode With a Pulse Driving Mode
    Lei Wei
    Zhang Xiaobing
    Lou Chaogang
    Zhao Zhiwei
    Wang Baoping
    IEEE ELECTRON DEVICE LETTERS, 2009, 30 (05) : 571 - 573
  • [45] Transmission type flat-panel X-ray source using ZnO nanowire field emitters
    Chen, Daokun
    Song, Xiaomeng
    Zhang, Zhipeng
    Li, Ziping
    She, Juncong
    Deng, Shaozhi
    Xu, Ningsheng
    Chen, Jun
    APPLIED PHYSICS LETTERS, 2015, 107 (24)
  • [46] Perfusion analysis using a wide coverage flat-panel volume CT: Feasibility study
    Grasruck, M.
    Gupta, R.
    Reichardt, B.
    Klotz, E.
    Schmidt, B.
    Flohr, T.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [47] A Study on Carbon-Nanotube Local Oxidation Lithography Using an Atomic Force Microscope
    Kumar, Kitu
    Sul, Onejae
    Strauf, Stefan
    Choi, Daniel S.
    Fisher, Frank
    Prasad, Marehalli G.
    Yang, Eui-Hyeok
    IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2011, 10 (04) : 849 - 854
  • [48] High resolution x-ray imaging using amorphous silicon flat-panel arrays
    Xerox Palo Alto Research Cent, Palo Alto, United States
    IEEE Nucl Sci Symp Med Imaging Conf, (1073-1077):
  • [49] High resolution x-ray imaging using amorphous silicon flat-panel arrays
    Rahn, JT
    Lemmi, F
    Lu, JP
    Mei, P
    Apte, RB
    Street, RA
    Lujan, R
    Weisfield, RL
    Heanue, JA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) : 457 - 461
  • [50] Simulation study of a field emission triode structure using carbon-nanotube emitters
    Xie, CG
    IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2004, 3 (03) : 404 - 411