Development and Performance Evaluation of Parallel Link Type Human Ankle Rehabilitation Assistive Device

被引:0
|
作者
Yonezawa, Teru [1 ]
Nomura, Kenta [1 ]
Onodera, Takayuki [1 ]
Ding, Ming [2 ]
Mizoguchi, Hiroshi [1 ]
Takemura, Hiroshi [1 ]
机构
[1] Tokyo Univ Sci, 2641 Yamazaki, Noda, Chiba, Japan
[2] Nagoya Univ, Chikusa Ku, Nagoya, Aichi, Japan
关键词
STROKE; MOTION; RELIABILITY; RANGE;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a novel rehabilitation assistive device called a "parallel link type human ankle rehabilitation assistive device (PHARAD)." It can accurately measure foot motions in six degrees of freedom and reproduce the ankle joint motions. By reproducing the input motions of the ankle joint, PHARAD conducts passive exercises for ankle rehabilitation. To measure and reproduce complex foot motions, we adopted a parallel link mechanism using six pneumatic cylinders with displacement sensors. In this research, we define the motions of a foot plate attached to a foot sole as the foot motions. A posture of the foot plate, i.e., the three-dimensional (3D) position (x, y, z) and rotation angle (theta, phi, psi), is numerically calculated by solving the forward kinematics of the PHARAD. We conducted two kinds of experiments to evaluate the performance of the PHARAD. First, verification experiments for the accuracy were implemented by comparing the measured motions of the foot plate by the PHARAD with those obtained by a motion capture system. The experimental results showed that the maximum root mean square error (RMSE) values of the 3D position and rotation angle were 2.6 mm and 1.5 degrees, respectively. Then, verification experiments for the reproducibility were implemented by comparing the reproduced motions with the input motions. The experimental results showed that the RMSE values of the 3D position and rotation angle were 5.6 mm and 6.1 degrees, respectively. Moreover, after reproducing the input motions ten times, the standard deviations of the 3D position and rotation angle were 1.4 mm and 0.7 degrees espectively. These experimental results show that the PHARAD can precisely measure and reproduce complex ankle motions, and has the potential to reproduce the exercise therapy presented by physical therapists.
引用
收藏
页码:802 / 807
页数:6
相关论文
共 50 条
  • [31] Fitts' Evaluation of a Developed Human-in-the-Loop Assistive Device
    Antunes, Rui Azevedo
    Palma, Luis Brito
    2020 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2020,
  • [32] Force, stiffness and viscous damping control in six degrees of freedom of the ankle-foot rehabilitation assistive device
    Onodera, Takayuki
    Yonezawa, Teru
    Ding, Ming
    Takemura, Hiroshi
    Transactions of Japanese Society for Medical and Biological Engineering, 2014, 52 (02): : 88 - 96
  • [33] Development of wearable rehabilitation device using parallel link mechanism: rehabilitation of compound motion combining palmar/dorsi flexion and radial/ulnar deviation
    Kitano Y.
    Tanzawa T.
    Yokota K.
    ROBOMECH Journal, 5 (1):
  • [34] Kinematic Performance Analysis of a Parallel Ankle Rehabilitation Robot with Sufficient Distance Adjustment
    Xie, Yunfei
    Zhong, Xiangqiang
    Wei, Jingyuan
    Shi, Ruifang
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF MECHANICAL ENGINEERING, 2025,
  • [35] A Parallel Robot for Ankle Rehabilitation-Evaluation and its Design Specifications.
    Syrseloudis, Christos E.
    Emiris, Ioannis Z.
    8TH IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING, VOLS 1 AND 2, 2008, : 1046 - 1051
  • [36] User Evaluation of the MOBOT rollator type robotic mobility assistive device
    Koumpouros, Yiannis
    Karavasili, Alexandra
    Efthimiou, Eleni
    Fotinea, Stavroula-Evita
    Goulas, Theodore
    Vacalopoulou, Anna
    10TH ACM INTERNATIONAL CONFERENCE ON PERVASIVE TECHNOLOGIES RELATED TO ASSISTIVE ENVIRONMENTS (PETRA 2017), 2017, : 354 - 359
  • [37] Creation and Evaluation of Human Models with Varied Walking Ability from Motion Capture for Assistive Device Development
    Chan, Sherwin Stephen
    Lei, Mingyuan
    Johan, Henry
    Ang, Wei Tech
    2023 INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS, ICORR, 2023,
  • [38] Evaluation of the lateral instability of the ankle by inversion simulation device and assessment of the rehabilitation program
    Urguden, Mustafa
    Kizilay, Ferah
    Sekban, Hazim
    Samanci, Nehir
    Ozkaynak, Sibel
    Ozdemir, Hakan
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2010, 44 (05) : 365 - 377
  • [39] Development of a hydraulic force display of parallel link type
    Kudomi, S
    Yamada, H
    Muto, T
    VSMM 2000: 6TH INTERNATIONAL CONFERENCE ON VIRTUAL SYSTEMS AND MULTIMEDIA, 2000, : 381 - 386
  • [40] Test-Stand Development and Performance Analysis of RoboWalk Assistive Device
    Moosavian, S. Ali A.
    Mahdizadeh, Omid
    Akbari, Vahid
    Nabipour, Mahdi
    Ghanaat, Sina
    Naeemi, Shahin
    Hallajian, Sina
    Beydokhti, Arash T.
    2022 10TH RSI INTERNATIONAL CONFERENCE ON ROBOTICS AND MECHATRONICS (ICROM), 2022, : 152 - 158