Three-dimensional high-resolution fast spin-echo coronary magnetic resonance angiography

被引:0
|
作者
Stuber, M
Botnar, RM
Spuentrup, E
Kissinger, KV
Manning, WJ
机构
[1] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[2] Philips Med Syst, Best, Netherlands
[3] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[4] Harvard Univ, Sch Med, Boston, MA USA
关键词
coronary MRA; three-dimensional; black-blood; dual-inversion; high resolution;
D O I
10.1002/1522-2594(200102)45:2<206::AID-MRM1028>3.0.CO;2-L
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Due to SNR constraints, current "bright-blood" 3D coronary MRA approaches still suffer from limited spatial resolution when compared to conventional x-ray coronary angiography, Recent 2D fast spin-echo black-blood techniques maximize signal for coronary MRA at no loss in image spatial resolution. This suggests that the extension of black-blood coronary MRA with a 3D imaging technique would allow for a further signal increase, which may be traded for an improved spatial resolution. Therefore, a dual-inversion 3D fast spin-echo imaging sequence and real-time navigator technology were combined for high-resolution free-breathing black-blood coronary MRA, Inplane image resolution below 400 mum was obtained. Magn Reson Med 45:206-211, 2001, (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:206 / 211
页数:6
相关论文
共 50 条
  • [21] Three-dimensional fast recovery fast spin-echo imaging of the inner ear and the vestibulocochlear nerve
    K. Nakashima
    M. Morikawa
    H. Ishimaru
    M. Ochi
    H. Kabasawa
    K. Hayashi
    European Radiology, 2002, 12 : 2776 - 2780
  • [23] Three-dimensional fast recovery fast spin-echo imaging of the inner ear and the vestibulocochlear nerve
    Nakashima, K
    Morikawa, M
    Ishimaru, H
    Ochi, M
    Kabasawa, H
    Hayashi, K
    EUROPEAN RADIOLOGY, 2002, 12 (11) : 2776 - 2780
  • [24] Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiography
    Stuber, M
    Botnar, RM
    Danias, PG
    Sodickson, DK
    Kissinger, KV
    Van Cauteren, M
    De Becker, J
    Manning, WJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (02) : 524 - 531
  • [25] Fast spin-echo for multiple mouse magnetic resonance phenotyping
    Nieman, BJ
    Bock, NA
    Bishop, J
    Sled, JG
    Chen, XJ
    Henkelman, RM
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (03) : 532 - 537
  • [26] Low-cost high-resolution fast spin-echo MR of acoustic schwannoma: An alternative to enhanced conventional spin-echo MR?
    Allen, RW
    Harnsberger, HR
    Shelton, C
    King, B
    Bell, DA
    Miller, R
    Parkin, JL
    Apfelbaum, RI
    Parker, D
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1996, 17 (07) : 1205 - 1210
  • [27] Knee Imaging: Rapid Three-Dimensional Fast Spin-Echo Using Compressed Sensing
    Kijowski, Richard
    Rosas, Humberto
    Samsonov, Alexey
    King, Kevin
    Peters, Rob
    Liu, Fang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (06) : 1712 - 1722
  • [28] POSTOPERATIVE ARACHNOIDITIS DIAGNOSED BY HIGH-RESOLUTION FAST SPIN-ECHO MRI OF THE LUMBAR SPINE
    FITT, GJ
    STEVENS, JM
    NEURORADIOLOGY, 1995, 37 (02) : 139 - 145
  • [29] MR urography: Evaluation of a three-dimensional fast spin-echo technique in patients with hydronephrosis
    OMalley, ME
    Soto, JA
    Yucel, EK
    Hussain, S
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (02) : 387 - 392
  • [30] EVALUATION OF MENISCAL TEARS - FAST SPIN-ECHO VERSUS CONVENTIONAL SPIN-ECHO MAGNETIC-RESONANCE-IMAGING
    ANDERSON, MW
    RAGHAVAN, N
    SEIDENWURM, DJ
    GREENSPAN, A
    DRAKE, C
    ACADEMIC RADIOLOGY, 1995, 2 (03) : 209 - 214