Assessment of a Novel 3T MRI Compatible Cochlear Implant Magnet: Torque, Forces, Demagnetization, and Imaging

被引:16
|
作者
Tysome, James Russell [1 ]
Tam, Yu Chuen [2 ]
Patterson, Ilse [3 ]
Graves, Martin John [1 ]
Gazibegovic, Dzemal [4 ]
机构
[1] Cambridge Univ Hosp, Cambridge Biomed Campus,Hills Rd, Cambridge, England
[2] Emmeline Ctr, Hills Rd, Cambridge, England
[3] Radiol Dept, Hills Rd, Cambridge, England
[4] AB GmbH, ERC, Hannover, Germany
关键词
Cochlear implant; Imaging; Magnet; Magnetic resonance imaging; Torque; Ultra; 3D; AUDITORY BRAIN-STEM; SAFETY;
D O I
10.1097/MAO.0000000000002407
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Hypothesis: A novel cochlea implant (CI) device magnet providing alignment to the static field of a magnetic resonance imaging (MRI) will lead to reduced torque, longitudinal forces, and demagnetization effects. The image void and distortion will be comparable to those obtained with standard CI magnets. Background: MRI investigations of CI users pose several challenges such as magnet dislocation, demagnetization, and may cause pain. The presence of a CI magnet within MRI field causes image distortions and may diminish the diagnostic value of an MRI procedure. Objective of this work is to evaluate magnetic forces and imaging properties of the novel CI magnet within 1.5 and 3T MRI. Methods: Forces and torque of the novel CI magnet were measured in both 1.5 and 3T MRI and compared with the standard magnet in 1.5T. One cadaver head was implanted with the CI devices containing the novel and standard magnets in different configurations reflecting clinical scenarios and imaging properties were assessed and compared. Results: In particular the torque has been reduced with the novel CI magnet in comparison to the standard one. Both CI magnets have not shown any signs of demagnetization. The image void and distortion was comparable between the two magnets for the main MRI clinical scanning protocols in 1.5T MRI. Conclusions: The novel CI magnet is safe to use for MRI investigations of CI users in 3T MRI without a need for bandaging and has acceptable level of image artefacts.
引用
收藏
页码:E966 / E974
页数:9
相关论文
共 50 条
  • [31] Development of a Bi-2223 HTS Magnet for 3T MRI System for Human Brains
    Kitaguchi, Hitoshi
    Ozaki, Osamu
    Miyazaki, Takayoshi
    Ayai, Naoki
    Sato, Ken-ichi
    Urayama, Shin-ichi
    Fukuyama, Hidenao
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 710 - 713
  • [32] Imaging of islets of Langerhans by MRI 3T: monitoring of graft rejection in rats
    Borot, S.
    Crowe, L.
    Ris, F.
    Masson, S.
    Morel, P.
    Vallee, J. -P.
    Berney, T.
    DIABETES & METABOLISM, 2011, 37 : A67 - A67
  • [33] Dynamic Volume Assessment of Hepatocellular Carcinoma in Rat Livers Using a Clinical 3T MRI and Novel Segmentation
    Orci, Lorenzo A.
    Oldani, Graziano
    Lacotte, Stephanie
    Slits, Florence
    Friedli, Iris
    Wirth, Wolfgang
    Toso, Christian
    Vallee, Jean-Paul
    Crowe, Lindsey A.
    JOURNAL OF INVESTIGATIVE SURGERY, 2018, 31 (01) : 44 - 53
  • [34] The value of high-field MRI (3T) in the assessment of sellar lesions
    Pinker, K
    Ba-Ssalamah, A
    Wolfsberger, S
    Mlynarik, V
    Knosp, E
    Trattnig, S
    EUROPEAN JOURNAL OF RADIOLOGY, 2005, 54 (03) : 327 - 334
  • [35] ASSESSMENT OF RESPONSE TO NEOADJUVANT CHEMOTHERAPY WITH DIFFUSION WEIGHTED IMAGING AT 3T
    Pinker-Domenig, K.
    Bickel, H.
    Bogner, W.
    Dubsky, P. C.
    Rudas, M.
    Bago-Horvath, Z.
    Helbich, T.
    ANNALS OF ONCOLOGY, 2012, 23 : 32 - 32
  • [36] Assessment of adipose tissue from whole body 3T MRI scans
    Song, Ting
    An, Jing
    Chen, Qun
    Lee, Vivian
    Laine, Andrew
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 7012 - 7015
  • [37] Cortical cerebral microinfarcts on 3T MRI A novel marker of cerebrovascular disease
    Hilal, Saima
    Sikking, Emiel
    Shaik, Muhammad Amin
    Chan, Qun Lin
    van Veluw, Susanne J.
    Vrooman, Henri
    Cheng, Ching-Yu
    Sabanayagam, Charumathi
    Cheung, Carol Y.
    Wong, Tien Yin
    Venketasubramanian, Narayanaswamy
    Biessels, Geert Jan
    Chen, Christopher
    Ikram, Mohammad Kamran
    NEUROLOGY, 2016, 87 (15) : 1583 - 1590
  • [38] Wireless video transmission into the MRI magnet room: implementation and evaluation at 1.5T, 3T and 7T
    Hensen, Bennet
    Kaegebein, Urte
    Gutberlet, Marcel
    Ringe, Kristina, I
    Van Dai Vo-Chieu
    Stucht, Daniel
    Speck, Oliver
    Vick, Ralf
    Wacker, Frank
    Pannicke, Enrico
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2019, 64 (04): : 373 - 382
  • [39] A Novel Flexible Electrotextile 3T MRI RF Coil Array for Carotid Artery Imaging: Design, Characterization, and Prototyping
    Zhang, Daisong
    Rahmat-Samu, Yahya
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2019, 67 (08) : 5115 - 5125
  • [40] Applications of dielectric pads, novel materials and resonators in 1.5T and 3T MRI
    Slobozhanyuk, A.
    Zivkovic, I.
    Shchelokova, A.
    Mikhailovskaya, A.
    Sushkov, I.
    Nenasheva, E.
    Melchakova, I.
    Belov, P.
    Webb, A.
    METANANO 2019, 2020, 1461