The fieldwork and control engineering studies on thermal comfort of occupants in a conventional office building in the tropics

被引:2
|
作者
Yau, Y. H. [1 ]
Chang, C. P. [1 ]
机构
[1] Univ Malaya, Dept Mech Engn, Kuala Lumpur 50603, Malaysia
关键词
Fuzzy logic; thermostat; thermal comfort; actual mean vote; air conditioning; ENERGY; DESIGN;
D O I
10.1177/0143624415611580
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the fieldwork and the control system studies to examine and improve the thermal comfort of the occupants in a typical office building in Malaysia. The proposed control system works as the basis of adjusting the thermostat setting at a certain period of time with the degree of using the fuzzy logic. The thermostat of the central AC system has its set point fixed between 21? and 22?, slightly below the range of 23-26? as recommended by Malaysian Standard MS1525. In order to maintain the room comfort, the occupants choose to switch OFF the central AC system for a certain period of time before it is switched back ON. It has been repeated at least once per working days. Therefore, the proposed control system is designed to overcome this practice. Pre- and post-comfort surveys have been conducted where the thermal comfort level of the occupants throughout this study is investigated. The air temperature (T-a), globe temperature (T-g), air velocity (V) and relative humidity (RH) in the occupied area were data-logged for continuous five working days. These data are used to compute the operative temperature (T-op) before new thermostat set points are generated, which indicates possible adjustment from the recommended set-point (24?). The proposed thermostat setting has an error tolerance of 2.9% or less. As a result, the simulation results show an adjustment of the thermostat setting from 24? to 25.5?, which successfully maintained the room temperature of the main office between 23.3? and 25?. The relative humidity is maintained between 54.3% and 59.8%. Also, these outcomes have indirectly promoted an average increase of 22.6% in the thermal comfort satisfactory level of the occupants. Practical application: The new conclusions from the simplified thermostat control strategy, which can be customised according to the environment variables in the air-conditioned space (in this case the operative temperature and the relative humidity) or based on the preferences of the occupants, such as the level of thermal comfort that suits the current thermal environment in tropical climates, could be applied as an important guide for building services engineers and researchers. Their aims are to reduce energy usage in HVAC systems in the non-green office buildings in tropical climates while maintaining an adequate thermal comfort level, and thus, the performance and well-being of the office workers are improved.
引用
收藏
页码:355 / 373
页数:19
相关论文
共 50 条
  • [31] A Review on Adaptive Thermal Comfort of Office Building for Energy-Saving Building Design
    Lamsal, Prativa
    Bajracharya, Sushil Bahadur
    Rijal, Hom Bahadur
    ENERGIES, 2023, 16 (03)
  • [32] Evaluation of thermal comfort in an office building in the humid tropical climate of Benin
    Kiki, Gratien
    Kouchade, Clement
    Houngan, Aristide
    Zannou-Tchoko, Stephen Junior
    Andre, Philippe
    BUILDING AND ENVIRONMENT, 2020, 185 (185)
  • [33] Thermal comfort and visual comfort in an office building equipped with smart electrochromic glazing: an experimental study
    Ajaji, Youness
    Andre, Philippe
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 2464 - 2469
  • [34] Thermal and visual comfort in a office building with double skin façade
    Heim, Dariusz
    Janicki, Marcin
    Szczepanska, Eliza
    10th International Conference on Healthy Buildings 2012, 2012, 2 : 1801 - 1806
  • [35] Predicting Thermal Comfort in Mixed-mode Office Building in the UK
    Luo, Xiaoyan
    Eftekhari, Mahroo
    Durrani, Faisal
    Kanhirothkandi, Dulhas Maliyekkal
    ASHRAE TRANSACTIONS 2019, VOL 125, PT 1, 2019, 125 : 158 - 166
  • [36] Comfort Temperature Control of heating office building system with Predictive Control Algorithms
    Ouali, Nassima
    Lehouche, Hocine
    Achour, A. Yazid
    PROGRAM OF THE 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND AUTOMATIC CONTROL, ICEEAC 2024, 2024,
  • [37] Comparison of passive cooling techniques in improving thermal comfort of occupants of a pre-fabricated building
    Samani, Pouya
    Leal, Vitor
    Mendes, Adelio
    Correia, Nuno
    ENERGY AND BUILDINGS, 2016, 120 : 30 - 44
  • [38] Energy saving and thermal comfort interventions based on occupants' needs: A students' residence building case
    Petidis, Loannis
    Aryblia, Maria
    Daras, Tryfon
    Tsoutsos, Theocharis
    ENERGY AND BUILDINGS, 2018, 174 : 347 - 364
  • [39] DISTRIBUTED SIMULATION FRAMEWORK TO ANALYZE THE ENERGY EFFECTS OF ADAPTIVE THERMAL COMFORT BEHAVIOR OF BUILDING OCCUPANTS
    Thomas, Albert
    Menassa, Carol C.
    Kamat, Vineet R.
    2016 WINTER SIMULATION CONFERENCE (WSC), 2016, : 3225 - 3236
  • [40] Factors influencing occupants' blind-control behaviour in a naturally ventilated office building
    Zhang, Yufan
    Barrett, Peter
    BUILDING AND ENVIRONMENT, 2012, 54 : 137 - 147