Inverse planning for IMRT with nonuniform beam profiles using total-variation regularization (TVR)

被引:23
|
作者
Kim, Taeho [1 ,2 ]
Zhu, Lei [3 ]
Suh, Tae-Suk [2 ]
Geneser, Sarah [1 ]
Meng, Bowen
Xing, Lei [1 ]
机构
[1] Stanford Univ, Dept Radiat Oncol, Stanford, CA 94305 USA
[2] Catholic Univ Korea, Dept Biomed Engn, Seoul 137701, South Korea
[3] Georgia Inst Technol, George W Woodruff Sch Mech Engn, Atlanta, GA 30332 USA
基金
新加坡国家研究基金会;
关键词
IMRT; total-variation; compressed sensing; inverse planning; flattening filter; DIRECT-APERTURE OPTIMIZATION; PHOTON BEAMS; RADIATION-THERAPY; FLATTENING FILTER; RADIOTHERAPY; DELIVERY; MODULATION;
D O I
10.1118/1.3521465
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Radiation therapy with high dose rate and flattening filter-free (FFF) beams has the potential advantage of greatly reduced treatment time and out-of-field dose. Current inverse planning algorithms are, however, not customized for beams with nonuniform incident profiles and the resultant IMRT plans are often inefficient in delivery. The authors propose a total-variation regularization (TVR)-based formalism by taking the inherent shapes of incident beam profiles into account. Methods: A novel TVR-based inverse planning formalism is established for IMRT with nonuniform beam profiles. The authors introduce a TVR term into the objective function, which encourages piecewise constant fluence in the nonuniform FFF fluence domain. The proposed algorithm is applied to lung and prostate and head and neck cases and its performance is evaluated by comparing the resulting plans to those obtained using a conventional beamlet-based optimization (BBO). Results: For the prostate case, the authors' algorithm produces acceptable dose distributions with only 21 segments, while the conventional BBO requires 114 segments. For the lung case and the head and neck case, the proposed method generates similar coverage of target volume and sparing of the organs-at-risk as compared to BBO, but with a markedly reduced segment number. Conclusions: TVR-based optimization in nonflat beam domain provides an effective way to maximally leverage the technical capacity of radiation therapy with FFF fields. The technique can generate effective IMRT plans with improved dose delivery efficiency without significant deterioration of the dose distribution. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3521465]
引用
收藏
页码:57 / 66
页数:10
相关论文
共 50 条
  • [21] Optoacoustic model-based inversion using anisotropic adaptive total-variation regularization
    Biton, Shai
    Arbel, Nadav
    Drozdov, Gilad
    Gilboa, Guy
    Rosenthal, Amir
    PHOTOACOUSTICS, 2019, 16
  • [22] Multilevel algorithm for a Poisson noise removal model with total-variation regularization
    Chan, Raymond H.
    Chen, Ke
    INTERNATIONAL JOURNAL OF COMPUTER MATHEMATICS, 2007, 84 (08) : 1183 - 1198
  • [23] Delaunay-Triangulation-Based Learning With Hessian Total-Variation Regularization
    Pourya, Mehrsa
    Goujon, Alexis
    Unser, Michael
    IEEE OPEN JOURNAL OF SIGNAL PROCESSING, 2023, 4 : 167 - 178
  • [24] PET Reconstruction From Truncated Projections Using Total-Variation Regularization for Hadron Therapy Monitoring
    Cabello, J.
    Torres-Espallardo, I.
    Gillam, J. E.
    Rafecas, M.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (05) : 3364 - 3372
  • [25] First-arrival traveltime tomography with modified total-variation regularization
    Jiang, Wenbin
    Zhang, Jie
    GEOPHYSICAL PROSPECTING, 2017, 65 (05) : 1138 - 1154
  • [26] Acoustic- and elastic-waveform inversion using a modified total-variation regularization scheme
    Lin, Youzuo
    Huang, Lianjie
    GEOPHYSICAL JOURNAL INTERNATIONAL, 2015, 200 (01) : 489 - 502
  • [27] Multi-frame image Super-resolution by total-variation regularization
    Xu, Z. (yangzij@lut.cn), 1600, Binary Information Press, Flat F 8th Floor, Block 3, Tanner Garden, 18 Tanner Road, Hong Kong (09):
  • [28] Learning of Continuous and Piecewise-Linear Functions With Hessian Total-Variation Regularization
    Campos, Joaquim
    Aziznejad, Shayan
    Unser, Michael
    IEEE OPEN JOURNAL OF SIGNAL PROCESSING, 2022, 3 : 36 - 48
  • [29] Ultrasound bent-ray tomography with a modified total-variation regularization scheme
    Intrator, Miranda
    Lin, Youzuo
    Chen, Ting
    Shin, Junseob
    Huang, Lianjie
    MEDICAL IMAGING 2015: ULTRASONIC IMAGING AND TOMOGRAPHY, 2015, 9419
  • [30] Ultrasound waveform tomography with the total-variation regularization for detection of small breast tumors
    Lin, Youzuo
    Huang, Lianjie
    Zhang, Zhigang
    MEDICAL IMAGING 2012: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2012, 8320