An image-based rat model for Monte Carlo organ dose calculations

被引:29
|
作者
Wu, Li [1 ]
Zhang, Guozhi [1 ]
Luo, Qingming [1 ]
Liu, Qian [1 ]
机构
[1] Huazhong Univ Sci & Technol, Wuhan Natl Lab Optoelect, Britton Chance Ctr Biomed Photon, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
voxel; organ dose; Monte Carlo;
D O I
10.1118/1.2952647
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An anatomically realistic rat model was developed from color images of successive cryosections of a mature Sprague-Dawley rat. Images were obtained, by digital scanning, of 9475 slices with thickness of 0.02 mm. A total of 13 major organs and tissues were selected, and models of these organs and tissues constructed from the images were used for calculations of absorbed dose from external photon sources. A detailed set of conversion coefficients from kerma free-in-air to organ absorbed dose have been calculated for external monoenergetic photon beams with energies ranging from 10 keV to 10 MeV under five idealized irradiation conditions (left lateral, right lateral, dorsal-ventral, ventral-dorsal, and isotropic) using the Monte Carlo code MCNPX. Dose results are presented in form of tables as supplemental data for practical use and comparison. The influence of anatomical characteristics, including organ volume, shape, location, and orientation, on dose distributions were evaluated. It would also be possible to make internal dose assessments using the computational rat model. (c) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:3759 / 3764
页数:6
相关论文
共 50 条
  • [41] Uncertainties in Monte Carlo-based absorbed dose calculations for an experimental benchmark
    Renner, F.
    Wulff, J.
    Kapsch, R-P
    Zink, K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (19): : 7637 - 7653
  • [42] Monte Carlo based dose calculations for quality assurance in the electronic medical record
    Linton, N.
    Pencea, S.
    Krivosheev, O.
    Napolitano, M.
    Alber, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2470 - 2470
  • [43] Benchmarking of Monte Carlo based shutdown dose rate calculations for applications to jet
    Petrizzi, L
    Batistoni, P
    Fischer, U
    Loughlin, M
    Pereslavtsev, P
    Villari, R
    RADIATION PROTECTION DOSIMETRY, 2005, 115 (1-4) : 80 - 85
  • [44] Monte Carlo Based Multidetector CT Modeling and Dose Calculations for Pregnant Patients
    Gu, J.
    Caracappa, P.
    Xu, X.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [45] Site-Specific Comparison of Analytical and Monte Carlo Based Dose Calculations
    Schuemann, J.
    Dowdell, S.
    Grassberger, C.
    Paganetti, H.
    MEDICAL PHYSICS, 2014, 41 (06) : 534 - 534
  • [46] Monte Carlo-based software for 3D personalized dose calculations in image-guided radiotherapy
    Le Deroff, Coralie
    Berger, Lucie
    Bellec, Julien
    Boissonnat, Guillaume
    Chesneau, Helena
    Chiavassa, Sophie
    Desrousseaux, Julie
    Gempp, Stephanie
    Henry, Olivier
    Jarril, Jimmy
    Lazaro, Delphine
    Lefeuvre, Ronan
    Passal, Vincent
    Solinhac, Fanny
    Lafond, Caroline
    Delpon, Gregory
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 21 : 108 - 114
  • [47] A proposal for virtual reality dose simulation using image-based deformable anatomical modeling and dynamic Monte Carlo method.
    Xu, XG
    HEALTH PHYSICS, 2002, 82 (06): : S142 - S142
  • [48] Image-Based Monte Carlo Modeling of Ca2+ sparks in Ventricular Myocytes
    Fan, Junjie
    Yu, Zeyun
    BIOPHYSICAL JOURNAL, 2009, 96 (03) : 278A - 278A
  • [49] Experimental verification of a Monte Carlo-based MLC simulation model for IMRT dose calculations in heterogeneous media
    Tyagi, N.
    Curran, B. H.
    Roberson, P. L.
    Moran, J. M.
    Acosta, E.
    Fraass, B. A.
    INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP, 2008, 102
  • [50] Monte Carlo shell-model calculations
    Otsuka, T
    Mizusaki, T
    Honma, M
    JOURNAL OF PHYSICS G-NUCLEAR AND PARTICLE PHYSICS, 1999, 25 (04) : 699 - 715