Ex vivo evaluation of the accuracy of two electronic apex locators during root canal length determination in primary teeth

被引:42
|
作者
Leonardo, M. R. [1 ]
Silva, L. A. B. [1 ]
Nelson-Filho, P. [1 ]
Silva, R. A. B. [1 ]
Raffaini, M. S. G. G. [1 ]
机构
[1] Univ Sao Paulo, Dept Pediat Prevent & Community Dent, Ribeirao Preto Sch Dent, Sao Paulo, Brazil
关键词
electronic apex locators; Mini Apex Locator; primary teeth; root canal length; root canal length measurement; Root Zx II;
D O I
10.1111/j.1365-2591.2007.01366.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. Methodology One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the actual canal length and using two electronic apex locators. Root canal length was measured both visually, with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using two electronic apex locators (Root ZX II - J. Morita Corp. and Mini Apex Locator - SybronEndo) according to the manufacturers' instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual root canal length and the electronic root canal length measurements revealed high correlation (ICC = 0.99), regardless of the tooth type (single-rooted and multi-rooted teeth) or the presence/absence of physiological root resorption. Conclusions Root ZX II and Mini Apex Locator proved useful and accurate for apex foramen location during root canal length measurement in primary incisors and molars.
引用
收藏
页码:317 / 321
页数:5
相关论文
共 50 条
  • [41] Comparison of working length determination with radiographs and two electronic apex locators
    Vieyra, J. P.
    Acosta, J.
    Mondaca, J. M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2010, 43 (01) : 16 - 20
  • [42] Accuracy of Three Electronic Apex Locators Compared with Digital Radiography: An Ex Vivo Study
    Cianconi, Luigi
    Angotti, Vincenzo
    Felici, Roberto
    Conte, Gabriele
    Mancini, Manuele
    JOURNAL OF ENDODONTICS, 2010, 36 (12) : 2003 - 2007
  • [43] Ex Vivo Evaluation of the Accuracy of Electronic Foramen Locators in Root Canals with an Obstructed Apical Foramen
    de Vasconcelos, Bruno Carvalho
    Verissimo Chaves, Rebeca Dibe
    Vivacqua-Gomes, Nilton
    de Miranda Candeiro, George Taccio
    Bernardes, Ricardo Affonso
    Vivan, Rodrigi Ricci
    Hungaro Duarte, Marco Antonio
    JOURNAL OF ENDODONTICS, 2015, 41 (09) : 1551 - 1554
  • [44] Accuracy of an electronic apex locator in primary teeth with root resorption
    Angwaravong, O.
    Panitvisai, P.
    INTERNATIONAL ENDODONTIC JOURNAL, 2009, 42 (02) : 115 - 121
  • [45] The Evaluation of Four Electronic Apex Locators in Teeth with Simulated Horizontal Oblique Root Fractures
    Goldberg, Fernando
    Frajlich, Santiago
    Kuttler, Sergio
    Manzur, Emilio
    Briseno-Marroquin, Benjamin
    JOURNAL OF ENDODONTICS, 2008, 34 (12) : 1497 - 1499
  • [46] Accuracy of working length determination with root ZX apex locator and radiography: An in vivo and ex vivo study
    Zand, Vahid
    Mokhtari, Hadi
    Lotfi, Mehrdad
    Reyhani, Mohammad Forough
    Sohrabi, Aydin
    Tehranchi, Pardis
    Zenouzi, Hamid Reza Mokhtari
    AFRICAN JOURNAL OF BIOTECHNOLOGY, 2011, 10 (36): : 7088 - 7091
  • [47] An Invitro Evaluation of the Accuracy of Two Electronic Apex Locators to Determine Working Length in the Presence of Various Irrigants
    Ashwini, Prasad B.
    Harshit, Srivastava
    Aastha, Srivastava Arora
    Deepak, Raisingani
    ETHIOPIAN JOURNAL OF HEALTH SCIENCES, 2016, 26 (05) : 457 - 462
  • [48] Comparing the accuracy of four electronic apex locators for determining the minor diameter: An ex vivo study
    Cimilli, Hale
    Aydemir, Seda
    Kartal, Nevin
    Chandler, Nicholas
    JOURNAL OF DENTAL SCIENCES, 2013, 8 (01) : 27 - 30
  • [49] Ex vivo comparison of radiographic and electronic root canal length measurements in primary molars
    Topaloglu-Ak, A.
    Yetkiner, A. Aykut
    Baksi, B. Guniz
    Eronat, C.
    EUROPEAN JOURNAL OF PAEDIATRIC DENTISTRY, 2015, 16 (02) : 149 - 153
  • [50] Ex vivo comparison of three electronic apex locators to determine working length in endodontic treatment
    Miguita, Kenner Bruno
    de Araujo, Roberta Aranha
    De Martin, Alexandre Sigrist
    da Silveira Bueno, Carlos Eduardo
    Cunha, Rodrigo Sanches
    ENDO-ENDODONTIC PRACTICE TODAY, 2011, 5 (04): : 281 - 284