Towards Real-Time Detection of Auditory Steady-State Responses: A Comparative Study

被引:2
|
作者
Wang, Lei [1 ]
Noordanus, Elisabeth [1 ]
Van Opstal, Adrianus Johannes [1 ]
机构
[1] Radboud Univ Nijmegen, Dept Biophys, Donders Ctr Neurosci, NL-6525 AJ Nijmegen, Netherlands
关键词
Detectors; Signal to noise ratio; Real-time systems; Electroencephalography; Steady-state; Time measurement; Maximum likelihood estimation; Auditory steady-state response; amplitude modulation stimuli; Bayes factor; EEG; high-order monaural beats; Neyman-Pearson detector; spectral F test; sequential probability ratio test; F-TEST; PHASE; COHERENCE; EEG;
D O I
10.1109/ACCESS.2021.3100157
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
To objectively evaluate weak neural responses such as auditory steady-state responses (ASSRs) often involves repetitive measurements, after which the accumulated trials are averaged or analyzed by statistical methods to detect a significant response. Such detection methods are often performed off-line on all measured trials. However, the number of required trials, and therefore the measurement time, is often heuristically chosen, and might be suboptimal. In this work, we compared three real-time signal-detection algorithms that could yield improved detection performance, at reduced measurement time. The classical Neyman-Pearson (NP) detector was evaluated by quantifying the signal-to-noise ratio (SNR), and detection probability of ASSRs, as a function of accumulated trial number. We also analyzed the performance of the Bayes factor (BF) to detect ASSRs at different thresholds. Finally, we modified the sequential probability ratio test (SPRT), with a cropped maximum likelihood (ML) estimator, such that it can detect ASSRs (with unknown SNRs) sequentially. We compared the three real-time detectors by using Monte Carlo simulation, and evaluated their performance on detecting ASSRs, generated from the superposition of a pair of amplitude-modulated (AM) tones near 40 Hz in the EEG of nine subjects with normal hearing. The low-order ASSRs (i.e., envelope frequency-following responses) have been sufficiently evaluated in the literature. However, the higher-order ASSRs might reflect further nonlinear mechanisms in the upper ascending auditory pathway. Results show that the real-time detectors can detect not only all low-order ASSRs but also higher-order ASSRs at frequencies with lower SNR. The NP detector yielded the best simulation and actual detection performance. For all subjects, the second-order ASSRs could already be detected with the NP and BF detectors within five trials, but more trials were needed for the modified SPRT detector. In general, higher-order ASSRs require more trials to detect, with the exception of ASSRs near 40 Hz and 80 Hz. In conclusion, compared with traditional off-line detectors, both (real-time) NP and BF detectors showed improved detection performance, and their application in EEG experiments can save valuable measurement time.
引用
收藏
页码:108975 / 108991
页数:17
相关论文
共 50 条
  • [21] Steady-state real-time optimization using transient measurements
    Krishnamoorthy, Dinesh
    Foss, Bjarne
    Skogestad, Sigurd
    COMPUTERS & CHEMICAL ENGINEERING, 2018, 115 : 34 - 45
  • [22] Artifactual responses when recording auditory steady-state responses
    Small, SA
    Stapells, DR
    EAR AND HEARING, 2004, 25 (06): : 611 - 623
  • [23] Magnetoencephalographic study of human auditory steady-state responses to binaural beat
    Karino, S
    Yumoto, M
    Itoh, K
    Uno, A
    Matsuda, M
    Yamakawa, K
    Sekimoto, S
    Kaneko, Y
    Kaga, K
    FRONTIERS IN HUMAN BRAIN TOPOGRAPHY, 2004, 1270 : 169 - 172
  • [24] Auditory steady-state responses reveal amplitude modulation gap detection thresholds
    Ross, B
    Pantev, C
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2004, 115 (05): : 2193 - 2206
  • [25] Evaluating Strategies for Improving the Detection of Auditory Steady-State Responses in the AUDIX System
    Arnaiz, Isabel
    Martinez-Montes, Eduardo
    Torres-Fortuny, Alejandro
    VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 1079 - 1084
  • [26] Comparative study between pure tone audiometry and auditory steady-state responses in normal hearing subjects
    de Oliveira Beck, Roberto Miquelino
    Ramos, Bernardo Faria
    Grasel, Signe Schuster
    Ramos, Henrique Faria
    de Moraes, Maria Flavia Bonadia B.
    de Almeida, Edigar Rezende
    Bento, Ricardo Ferreira
    BRAZILIAN JOURNAL OF OTORHINOLARYNGOLOGY, 2014, 80 (01) : 35 - 40
  • [27] On the terminology of auditory steady-state responses. What differentiates steady-state and transient potentials?
    Muehler, R.
    HNO, 2012, 60 (05) : 421 - 426
  • [28] NEUROMAGNETIC STEADY-STATE RESPONSES TO AUDITORY-STIMULI
    HARI, R
    HAMALAINEN, M
    JOUTSINIEMI, SL
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1989, 86 (03): : 1033 - 1039
  • [29] Intracerebral Sources of Human Auditory Steady-State Responses
    Anthony T. Herdman
    Otavio Lins
    Patricia Van Roon
    David R. Stapells
    Michael Scherg
    Terence W. Picton
    Brain Topography, 2002, 15 : 69 - 86
  • [30] Classification of Auditory Steady-State Responses to Speech Data
    Nakamura, T.
    Namba, H.
    Matsumoto, T.
    2013 6TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING (NER), 2013, : 1025 - 1028