First Clinical Evaluation of the C-MAC D-Blade Videolaryngoscope During Routine and Difficult Intubation

被引:90
|
作者
Cavus, Erol [1 ]
Neumann, Tobias [1 ]
Doerges, Volker [1 ]
Moeller, Thora [2 ]
Scharf, Edwin [1 ]
Wagner, Klaus [2 ]
Bein, Berthold [1 ]
Serocki, Goetz [1 ]
机构
[1] Univ Hosp Schleswig Holstein, Dept Anaesthesiol & Intens Care Med, D-24105 Kiel, Germany
[2] Klinikum Suedstadt Rostock, Dept Anaesthesiol & Intens Care Med, Rostock, Germany
来源
ANESTHESIA AND ANALGESIA | 2011年 / 112卷 / 02期
关键词
TRACHEAL INTUBATION; MACINTOSH LARYNGOSCOPE; AIRWAY MANAGEMENT; EMERGENCY;
D O I
10.1213/ANE.0b013e31820553fb
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
In the present preliminary study we evaluated the C-MAC (R) D-Blade (Karl Storz, Tuttlingen, Germany), a new videolaryngoscopic C-MAC blade for difficult intubation, during both routine and difficult intubations. First, both the conventional direct laryngoscopy and the D-Blade were used in 15 consecutive patients with normal airways during routine induction of anesthesia. Second, the D-Blade was used as a rescue device in 20 of 300 (6.7%) consecutive patients, when conventional direct laryngoscopy failed. In the 15 patients during routine induction of anesthesia, with direct laryngoscopy, a Cormack-Lehane (C/L) grade 1 and grade 2a view was seen in 7 and 8 patients, respectively. It was possible to insert the D-Blade and to get a video view of the glottis on the first attempt in all patients; with the D-Blade, all 15 patients had a C/L 1 view. The time to successful intubation with the D-Blade was 15 (8-26) seconds (median (range)). In the 20 patients, in whom unexpected difficulty with direct laryngoscopy was observed, C/L grades 3 and 4 were present in 15 and 5 patients, respectively. With the use of the D-Blade, indirect C/L video view improved to C/L class 1 in 15 patients, and to 2a in 5 patients, respectively. The time from touching the laryngoscope to optimal laryngoscopic view was 11(5-45) seconds and for successful intubation 17(3-80) seconds. In all 35 patients, with the D-Blade no direct view of the glottis was possible and subsequently a semiflexible tube guide was required. (Anesth Analg 2011;112:382-5)
引用
收藏
页码:382 / 385
页数:4
相关论文
共 50 条
  • [41] The use of the C-MAC videolaryngoscope for awake intubation in patients with a predicted extremely difficult airway: case series
    Gaszynski, Tomasz
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2018, 14 : 539 - 542
  • [42] Surprise: Unexpected Difficult Intubation in Both Living Donors and Recipient and Successful C-MAC Videolaryngoscope Experience
    Erenler, F.
    Bulutcu, F.
    Bozkurt, B.
    Dayangac, M.
    Yuzer, Y.
    Tokat, Y.
    TRANSPLANTATION, 2017, 101 (05) : 279 - 279
  • [43] Disposable C-MAC® videolaryngoscope blade - not the same as the re-usable blade
    Greenland, K. B.
    ANAESTHESIA, 2014, 69 (12) : 1402 - 1403
  • [44] Performance of C-MAC videolaryngoscope for intubation in cervical spine immobilization conditions
    Wang, Shi-Yu
    Xue, Fu-Shan
    Yang, Gui-Zhen
    Liu, Ya-Yang
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2018, 36 (06): : 1117 - 1118
  • [45] Clinical evaluation of C-MAC videolaryngoscope with or without use of stylet for endotracheal intubation in patients with cervical spine immobilization
    Nidhi Gupta
    Girija Prasad Rath
    Hemanshu Prabhakar
    Journal of Anesthesia, 2013, 27 : 663 - 670
  • [46] Comparison of Macintosh, McCoy and C-MAC D-Blade video laryngoscope intubation by prehospital emergency health workers: a simulation study
    Ahmet Yildirim
    Hasan A. Kiraz
    İbrahim Ağaoğlu
    Okhan Akdur
    Internal and Emergency Medicine, 2017, 12 : 91 - 97
  • [47] Comparison of C-MAC D-Blade with macintosh laryngoscope for endotracheal intubation in patients with cervical spine immobilization: A randomized controlled trial
    Agrawal, Nidhi
    Saini, Suman
    Gupta, Anju
    Kabi, Ankita
    Girdhar, K. K.
    TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2021, 37 : 35 - 41
  • [48] Clinical evaluation of C-MAC videolaryngoscope with or without use of stylet for endotracheal intubation in patients with cervical spine immobilization
    Gupta, Nidhi
    Rath, Girija Prasad
    Prabhakar, Hemanshu
    JOURNAL OF ANESTHESIA, 2013, 27 (05) : 663 - 670
  • [49] Factors Influencing the Time of Intubation Using C-MAC D-Blade? Video Laryngoscope: An Observational Cross-Sectional Study
    Gayathri, Balasubramaniam
    Mani, Karthik
    Vishak, Manoj
    John, Joy
    Srinivasan, Raghul G.
    Mirunalini, Gunaseelan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)
  • [50] COMPARISON OF THE EFFECTIVENESS BETWEEN C-MAC D-BLADE AND GLIDESCOPE RANGER FOR TRACHEAL INTUBATION IN SIMULATED PATIENT WITH CERVICAL SPINE IMMOBILISATION
    Zaini, R. H. Mohamad
    Wil, F. F. Che
    Hassan, W. N. Wan
    Iberahim, M. I.
    ANESTHESIA AND ANALGESIA, 2016, 123 : 695 - 695