Growth and partial discharge characteristics of DC electrical trees in cross-linked polyethylene

被引:21
|
作者
Liu, Hechen [1 ]
Zhang, Mingjia [1 ]
Liu, Yunpeng [1 ]
Xu, Xiaobin [1 ]
Liu, Aijing [1 ]
机构
[1] North China Elect Power Univ, Hebei Prov Key Lab Power Transmiss Equipment Secu, 619 Yonghua North St, Baoding City 071003, Peoples R China
关键词
DC electrical tree; growth properties; cross-linked polyethylene; partial discharge; SILICONE-RUBBER; GROUNDED DC; INITIATION; AC; DEPENDENCE; FEATURES; XLPE;
D O I
10.1109/TDEI.2019.008265
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the present study, the growth and partial discharges properties of DC electrical trees in cross-linked polyethylene (XLPE) were investigated under positive and negative DC voltages. The obtained results revealed that the voltage rise exerted significant influences on growth properties of DC trees. In either polarity, DC electrical trees grew rapidly during rising voltage and maintained the rapid growth for a certain time after DC voltage reached a constant value. The growth rate of positive DC electrical trees was quite faster than that of negative ones, and channel breakdown mainly occurred in positive ones. Although the growth rates of positive and negative DC electrical trees were different, their shapes were similar (both were branch-like electrical trees with one or two main branches). Self-healing usually occurred in negative DC electrical trees, thus electrical tree branches gradually disappeared under the application of steady DC voltage or when the voltage was off. Partial discharges mainly occurred at the beginning of electrical tree growth; however, the amount of partial discharge was relatively small, and it gradually reduced even during the rapid growth of electrical trees, consequently, almost no partial discharges were found when the voltage was constant. Finally, a discharge-avalanche theory was proposed to explain the growth properties of DC electrical trees.
引用
收藏
页码:1965 / 1972
页数:8
相关论文
共 50 条
  • [1] Partial Discharge Patterns on Cross-Linked Polyethylene DC Power Cables
    Siregar, Mutiara Sofia
    Schichler, Uwe
    Woschitz, Rudolf
    Pirker, Alexander
    Suwarno
    2016 3RD CONFERENCE ON POWER ENGINEERING AND RENEWABLE ENERGY (ICPERE), 2016, : 119 - 123
  • [2] Superiority of partial discharge characteristics of cross-linked polyethylene nanocomposites over microcomposites for electrical insulation application
    Paramane, Ashish Sharad
    Kannaiah, Sathish Kumar
    MICRO & NANO LETTERS, 2016, 11 (12) : 844 - 847
  • [3] Study on conducting characteristics of electrical trees in cross-linked polyethylene cable insulation
    Chen Xiang-Rong
    Xu Yang
    Liu Ying
    Cao Xiao-Long
    ACTA PHYSICA SINICA, 2012, 61 (08)
  • [4] Degradation of Low-density Polyethylene and Cross-linked Polyethylene by Partial Discharge
    Sekii, Yasuo
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (01) : 116 - 124
  • [5] Electrical field distribution on the cross-linked polyethylene insulation surface under partial discharge testing
    Morsalin, Sayidul
    Toan Phung
    POLYMER TESTING, 2020, 82
  • [6] Growth and Partial Discharge Characteristics of Electrical Treeing in Double Dynamic Cross-linked Vitrimer Resin and Its Degradation
    Liu, Hechen
    Sun, Zhanglin
    Wei, Liwei
    Liu, Chang
    Liu, Yunpeng
    Zhou, Songsong
    Liu, Jie
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2024, 44 (19): : 7852 - 7862
  • [7] Characteristics of Partial Discharge in Cross-linked Polyethylene insulation Cable under Damped AC Voltage
    Zhang, Wei
    Huang, Zhiwei
    Xue, Rong
    Zhang, Long
    Li, Hongjie
    Liu, Chongxin
    CURRENT DEVELOPMENT OF MECHANICAL ENGINEERING AND ENERGY, PTS 1 AND 2, 2014, 494-495 : 1444 - +
  • [8] EVALUATION OF FIELD AGED CROSS-LINKED POLYETHYLENE CABLES BY PARTIAL DISCHARGE LOCATION
    MASHIKIAN, MS
    LUTHER, R
    MCIVER, JC
    JURCISIN, J
    SPENCER, PW
    IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (02) : 620 - 628
  • [9] Numerical modelling, simulation and experimental validation of partial discharge in cross-linked polyethylene cables
    Joseph, Jineeth
    Mohan, Shilpa
    Krishnan, Sindhu Thiruthi
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2019, 13 (02) : 309 - 317
  • [10] Effect of Electrical Trees on the Distribution of Electric Field and Space Charge in Cross-linked Polyethylene Cables
    Li, Yasha
    Wang, Huiyao
    Chen, Kai
    Chen, Jiamao
    RECENT ADVANCES IN ELECTRICAL & ELECTRONIC ENGINEERING, 2021, 14 (01) : 114 - 121