Device-Based In Vitro Techniques for Mechanical Stimulation of Vascular Cells: A Review

被引:32
|
作者
Davis, Caleb A. [1 ]
Zambrano, Steve [1 ]
Anumolu, Pratima [1 ]
Allen, Alicia C. B. [2 ]
Sonoqui, Leonardo [1 ]
Moreno, Michael R. [3 ]
机构
[1] Texas A&M Univ, Dept Biomed Engn, College Stn, TX 77843 USA
[2] Univ Texas Austin, Dept Biomed Engn, Austin, TX 78712 USA
[3] Texas A&M Univ, Dept Mech Engn, Dept Biomed Engn, College Stn, TX 77843 USA
关键词
FLUID SHEAR-STRESS; NITRIC-OXIDE SYNTHASE; CYCLIC CIRCUMFERENTIAL STRETCH; ADHESION MOLECULE EXPRESSION; MESENCHYMAL STEM-CELLS; SMOOTH-MUSCLE-CELLS; ENDOTHELIAL-CELLS; UNIAXIAL STRAIN; GENE-EXPRESSION; PULSATILE FLOW;
D O I
10.1115/1.4029016
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The most common cause of death in the developed world is cardiovascular disease. For decades, this has provided a powerful motivation to study the effects of mechanical forces on vascular cells in a controlled setting, since these cells have been implicated in the development of disease. Early efforts in the 1970 s included the first use of a parallel-plate flow system to apply shear stress to endothelial cells (ECs) and the development of uniaxial substrate stretching techniques (Krueger et al., 1971, "An in Vitro Study of Flow Response by Cells," J. Biomech., 4(1), pp. 31-36 and Meikle et al., 1979, " Rabbit Cranial Sutures in Vitro: A New Experimental Model for Studying the Response of Fibrous Joints to Mechanical Stress," Calcif. Tissue Int., 28(2), pp. 13-144). Since then, a multitude of in vitro devices have been designed and developed for mechanical stimulation of vascular cells and tissues in an effort to better understand their response to in vivo physiologic mechanical conditions. This article reviews the functional attributes of mechanical bioreactors developed in the 21st century, including their major advantages and disadvantages. Each of these systems has been categorized in terms of their primary loading modality: fluid shear stress (FSS), substrate distention, combined distention and fluid shear, or other applied forces. The goal of this article is to provide researchers with a survey of useful methodologies that can be adapted to studies in this area, and to clarify future possibilities for improved research methods.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Evidence-based management of heart failure in clinical practice: a review of device-based therapy use
    Thavapalachandran, S.
    Leong, D. P.
    Stiles, M. K.
    John, B.
    Dimitri, H.
    Lau, D. H.
    Psaltis, P. J.
    Brooks, A. G.
    Alasady, M.
    Lim, H. S.
    Young, G. D.
    Sanders, P.
    INTERNAL MEDICINE JOURNAL, 2009, 39 (10) : 669 - 675
  • [22] In vivo safety and in vitro model assessment of a new device-based approach for treating diastolic heart failure
    Lak, L.
    Dubi, S.
    Feld, Y.
    Schwammenthal, S.
    Shofti, R.
    Sherman, A.
    Elami, A.
    EUROPEAN HEART JOURNAL, 2008, 29 : 27 - 27
  • [23] Review of pulmonary emboli and techniques for their mechanical removal to inform device design
    Brand J.
    McGowan R.
    Nimunkar A.
    Journal of Medical Engineering and Technology, 2020, 44 (05): : 255 - 265
  • [24] PHYSICAL ACTIVITY, SEASONALITY, AND WEATHER: A SCOPING REVIEW OF RESEARCH WITH DEVICE-BASED MEASURES OF PHYSICAL ACTIVITY
    Turrisi, Taylor B.
    West, Ashley B.
    Bittel, Kelsey M.
    Mama, Scherezade K.
    Hojjatinia, Sahar
    Hojjatinia, Sarah
    Lagoa, Constantino
    Conroy, David E.
    ANNALS OF BEHAVIORAL MEDICINE, 2020, 54 : S640 - S640
  • [25] Perceptions of Living With a Device-Based Treatment: An Account of Patients Treated With Deep Brain Stimulation for Parkinson's Disease
    Hariz, Gun-Marie
    Hamberg, Katarina
    NEUROMODULATION, 2014, 17 (03): : 272 - 278
  • [26] Using a Digital Twin of an Electrical Stimulation Device to Monitor and Control the Electrical Stimulation of Cells in vitro
    Zimmermann, Julius
    Budde, Kai
    Arbeiter, Nils
    Molina, Francia
    Storch, Alexander
    Uhrmacher, Adelinde M.
    van Rienen, Ursula
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [27] A REVIEW OF VASCULAR ANASTOMOSIS WITH MECHANICAL AIDS AND NON-SUTURE TECHNIQUES
    LEE, S
    WONG, L
    ORLOFF, MJ
    NAHUM, AM
    HEAD & NECK SURGERY, 1980, 3 (01): : 58 - 65
  • [28] 2D Localization with WiFi Passive Radar and Device-Based Techniques: An Analysis of Target Measurements Accuracy
    Milani, Ileana
    Colone, Fabiola
    Lombardo, Pierfrancesco
    2018 19TH INTERNATIONAL RADAR SYMPOSIUM (IRS), 2018,
  • [29] Review of Mechanical Testing and Modelling of Thrombus Material for Vascular Implant and Device Design
    S. Johnson
    S. Duffy
    G. Gunning
    M. Gilvarry
    J. P. McGarry
    P. E. McHugh
    Annals of Biomedical Engineering, 2017, 45 : 2494 - 2508
  • [30] Review of Mechanical Testing and Modelling of Thrombus Material for Vascular Implant and Device Design
    Johnson, S.
    Duffy, S.
    Gunning, G.
    Gilvarry, M.
    McGarry, J. P.
    McHugh, P. E.
    ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (11) : 2494 - 2508