Electrochemical activation of copper oxide decorated graphene oxide modified carbon paste electrode surface for the simultaneous determination of hazardous Di-hydroxybenzene isomers

被引:25
|
作者
Kumar, Mohan [1 ,2 ]
Swamy, B. E. Kumara [3 ]
Hu, Bin [1 ]
Wang, Miao [1 ,2 ]
Yasin, Ghulam [1 ,2 ]
Liang, Baiyao [1 ]
Madhuchandra, H. D. [3 ]
Zhao, Wei [1 ]
机构
[1] Shenzhen Univ, Inst Adv Study, Shenzhen 518060, Peoples R China
[2] Shenzhen Univ, Coll Phys & Optoelect Engn, Shenzhen 518060, Peoples R China
[3] Kuvempu Univ, Dept PG Studies & Res Ind Chem, Shimoga 577451, Karnataka, India
关键词
Hydroquinone; Catechol; Resorcinol; Sensor; Hazardous pollutants; Graphene oxide; AMPEROMETRIC DETERMINATION; VOLTAMMETRIC DETERMINATION; COMPOSITE ELECTRODE; HYDROQUINONE; CATECHOL; NANOCOMPOSITE; RESORCINOL; NANOPARTICLES; PERFORMANCE; ENHANCEMENT;
D O I
10.1016/j.microc.2021.106503
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction of a consistent electrochemical sensor is essential for the determination of hazardous pollutants in water and environments. Hydroquinone (HQ), catechol (CT), and resorcinol (RS) frequently coexist as priority pollutants in water and interfere with each other during identification, which poses a challenge for simultaneous and sensitive determination for those di-hydroxybenzene isomers. In this work, copper oxide (CuO) decorated graphene oxide (GO) nanocomposite (CuO/GO) was prepared and used to modify carbon paste electrode (CPE). The as-prepared electrode (CGCPE) was electrochemically activated in the presence of NaOH solution (Et-CGCPE) for the simultaneous determination of di-hydroxybenzene isomers (HQ, CT, and RS), and showed a well-defined oxidation peak with a significantly improved electrochemical response. We ascribe this high performance to the formation of electroactive functional groups on the electrode surface during the electrochemical activation and the synergistic effect between GO and CuO. Under the optimized conditions, the results show a long linear concentration range of HQ (0.2-360 mu M), CT (0.3-360 mu M), and RS (0.7-250 mu M) with the detection limits of 1.0 mu M, 1.1 mu M, and 1.8 mu M, respectively. The Et-CGCPE was effectively applied to detect three di-hydroxybenzene isomers in lake water with good repeatability and stability.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Simultaneous electrochemical determination of dopamine and paracetamol on multiwalled carbon nanotubes/graphene oxide nanocomposite-modified glassy carbon electrode
    Cheemalapati, Srikanth
    Palanisamy, Selvakumar
    Mani, Veerappan
    Chen, Shen-Ming
    TALANTA, 2013, 117 : 297 - 304
  • [32] Electrospun Manganese Oxide Nanofibers Modified Carbon Paste Electrode as the Novel Electrochemical Sensor for Sensitive Simultaneous Determination of Dopamine and Tyrosine
    Vazirirad, Ameneh
    Babaei, Ali
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (11): : 1610 - 1624
  • [33] Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline
    Vimal Sharma
    David Hynek
    Libuse Trnkova
    Dusan Hemzal
    Marian Marik
    Rene Kizek
    Jaromir Hubalek
    Microchimica Acta, 2016, 183 : 1299 - 1306
  • [34] Electrochemical determination of caffeine in beverage using graphene oxide modified glassy carbon electrode
    Murugan, E.
    Poongan, A.
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2021, 28 (05) : 528 - 536
  • [35] Electrochemical determination of levodopa on a reduced graphene oxide paste electrode modified with a metal-organic framework
    Naghian, Ebrahim
    Shahdost-fard, Faezeh
    Sohouli, Esmail
    Safarifard, Vahid
    Najafi, Mostafa
    Rahimi-Nasrabadi, Mehdi
    Sobhani-Nasab, Ali
    MICROCHEMICAL JOURNAL, 2020, 156
  • [36] Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline
    Sharma, Vimal
    Hynek, David
    Trnkova, Libuse
    Hemzal, Dusan
    Marik, Marian
    Kizek, Rene
    Hubalek, Jaromir
    MICROCHIMICA ACTA, 2016, 183 (04) : 1299 - 1306
  • [37] Electrochemical Determination of Papaverine on Mg-Al Layered Double Hydroxide/Graphene Oxide and CNT Modified Carbon Paste Electrode
    Rezaei, Behzad
    Heidarbeigy, Maliheh
    Ensafi, Ali A.
    Dinari, Mohammad
    IEEE SENSORS JOURNAL, 2016, 16 (10) : 3496 - 3503
  • [38] Electrochemical aptasensor based on carboxylated graphene oxide modified carbon paste electrode for strontium ultrasensitive detection
    Ebrahimi, Nastaran
    Raoof, Jahan Bakhsh
    Ojani, Reza
    Ebrahimi, Maryam
    ANALYTICAL BIOCHEMISTRY, 2023, 666
  • [39] A selective and sensitive electrochemical determination of catechol based on reduced graphene oxide decorated β-cyclodextrin nanosheet modified glassy carbon electrode
    Nikhil, S.
    Karthika, A.
    Suresh, P.
    Suganthi, A.
    Rajarajan, M.
    ADVANCED POWDER TECHNOLOGY, 2021, 32 (07) : 2148 - 2159
  • [40] Electrochemical determination of the antipsychotic medication clozapine by a carbon paste electrode modified with a nanostructure prepared from titania nanoparticles and copper oxide
    Ghanbari, Mohammad Hossein
    Shandost-Fard, Faezeh
    Rostami, Mojtaba
    Khoshroo, Alireza
    Sobhani-Nasab, Ali
    Gholipour, Nazila
    Salehzadeh, Hamid
    Ganjali, Mohammad Reza
    Rahimi-Nasrabadi, Mehdi
    Ahmadi, Farhad
    MICROCHIMICA ACTA, 2019, 186 (11)