Impact of inter-observer variations in target volume delineation on dose volume indices for accelerated partial breast irradiation with multicatheter interstitial brachytherapy

被引:8
|
作者
Upreti, Ritu Raj [1 ,4 ]
Budrukkar, Ashwini [2 ]
Upreti, Udita [1 ]
Wadasadawala, Tabassum [3 ]
Misra, Shagun [2 ]
Gurram, Lavanya [2 ]
Pathak, Rima [2 ]
Deshpande, Deepak D. [1 ,4 ]
机构
[1] Tata Mem Hosp, Dept Med Phys, Dr Ernest Borges Marg, Bombay 400012, Maharashtra, India
[2] Tata Mem Hosp, Dept Radiat Oncol, Bombay, Maharashtra, India
[3] Adv Ctr Treatment Res & Educ Canc, Dept Radiat Oncol, Bombay, Maharashtra, India
[4] Homi Bhabha Natl Inst, Training Sch Complex, Bombay, Maharashtra, India
关键词
Interobserver variation; Multicatheter interstitial brachytherapy; Dose volume indices; Accelerated partial breast irradiation; OPEN CAVITY SURGERY; IN-SITU CARCINOMA; CONSERVING SURGERY; FEMALE BREAST; CANCER; TRIAL; BOOST; RECOMMENDATIONS; UNCERTAINTIES; RADIOTHERAPY;
D O I
10.1016/j.radonc.2018.06.029
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate dosimetric impact of inter-observer variation in clinical target volume(CTV) delineation for patients undergoing interstitial partial breast brachytherapy. Methods: Five radiation oncologists delineated CTV in twenty patients who underwent multi-catheter partial breast brachytherapy. Five treatment plans for each patient were graphically optimized for CTV of all observers and evaluated using coverage index(CI), external volume index(EI), overdose volume index(OI) and conformal index(COIN). In addition, volume enclosed by prescription isodose(V100), its spatial concordance(CIcommon), mean coverage of all CTVs with common volume of prescription dose (V-100_common) and mean CTV coverage for all pairs of observer with common prescription volume of respective pairs(V100_ pair) were also computed. Results: The mean +/- standard deviation(SD) of CI and COIN ranged from 0.756 +/- 0.076 to 0.840 +/- 0.070 and 0.591 +/- 0.090 to 0.673 +/- 0.06 respectively. When a plan made for CTV of individual observer was evaluated on CTV of all observers, the maximum variations(q < 0.05) in the mean CI, COIN, OI and EI were 10.6%, 11.4%, 10.6% and 72.7% respectively. The observed mean +/- SD of V100, CIcommon of V100, CTV coverage with V-100_common and V-100_pair was 160.7 +/- 52.1, 0.70 +/- 0.09, 73.1 +/- 8.1% and 77.9 +/- 7.3% respectively. Conclusion: Inter-observer variation in delineation of CTV showed significant dosimetric impact with mean CTV coverage of 73.1% and 77.9% by common and paired prescription dose volume respectively among all observers. (C) 2018 Elsevier B. V. All rights reserved. Radiotherapy and Oncology
引用
收藏
页码:173 / 179
页数:7
相关论文
共 50 条
  • [32] Accelerated partial breast irradiation with interstitial multicatheter brachytherapy after breast -conserving surgery for low -risk early breast cancer
    Rodriguez-Ibarria, Nieves G.
    Pinar, Ma Beatriz
    Garcia, Laura
    Cabezon, M. Auxiliadora
    Lloret, Marta
    Rey-Baltar, Ma Dolores
    Rdguez-Melcon, J. Ignacio
    Lara, Pedro C.
    BREAST, 2020, 52 : 45 - 49
  • [33] CyberKnife versus multicatheter interstitial brachytherapy for accelerated partial breast irradiation: a dosimetrical assessment with focus on organs at risk
    Herein, Andras
    Stelczer, Gabor
    Pesznyak, Csilla
    Frohlich, Georgina
    Smanyko, Viktor
    Meszaros, Norbert
    Polgar, Csaba
    Takacsi-Nagy, Zoltan
    Major, Tibor
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2022, 27 (01) : 152 - 160
  • [34] Comparison of MRI and CT for Target Volume Delineation and Dose Coverage for Partial Breast Irradiation in Patients with Breast Cancer
    Song, Y.
    Xie, X.
    Che, S.
    Sun, G.
    Tang, Y.
    Zhang, J.
    Wang, J.
    Fang, H.
    Chen, B.
    Song, Y.
    Jin, J.
    Liu, Y.
    Qi, S.
    Tang, Y.
    Lu, N.
    Jing, H.
    Yang, Y.
    Li, N.
    Li, J.
    Wang, S.
    Li, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E76 - E77
  • [35] INTRA- AND INTER-OBSERVER VARIABILITY OF INTERNAL TARGET VOLUME DELINEATION AND VOLUME CHANGES OF LUNG TUMOURS ON REPEATED CT SCANS
    Petoukhova, A.
    Steyn, T.
    Kalidien, Y.
    Kouwenhoven, E.
    de Haan, P.
    Wiggenraad, R.
    Verbeek-de Kanter, A.
    van de Vaart, P.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S353 - S354
  • [36] Recommendations from GEC ESTRO Breast Cancer Working Group (I): Target definition and target delineation for accelerated or boost Partial Breast Irradiation using multicatheter interstitial brachytherapy after breast conserving closed cavity surgery
    Strnad, Vratislav
    Hannoun-Levi, Jean-Michel
    Guinot, Jose-Luis
    Loessl, Kristina
    Kauer-Dorner, Daniela
    Resch, Alexandra
    Kovacs, Gyoergy
    Major, Tibor
    Van Limbergen, Erik
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 (03) : 342 - 348
  • [37] Recommendations from GEC ESTRO Breast Cancer Working Group (II): Target definition and target delineation for accelerated or boost partial breast irradiation using multicatheter interstitial brachytherapy after breast conserving open cavity surgery
    Major, Tibor
    Gutierrez, Cristina
    Guix, Benjamin
    van Limbergen, Erik
    Strnad, Vratislav
    Polgar, Csaba
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 (01) : 199 - 204
  • [38] Analysis of multicatheter interstitial brachytherapy: Accelerated partial breast irradiation in a retrospective cohort of early-stage breast cancer patients
    Sigurdson, Samantha
    Thibodeau, Stephane
    Montgomery, Logan
    Olding, Tim
    Hopman, Wilma
    Korzeniowski, Martin
    BRACHYTHERAPY, 2024, 23 (01) : 52 - 57
  • [39] Low Cardiac Dose Achieved With Multicatheter Interstitial Accelerated Partial Breast Irradiation in Patients After Left Partial Mastectomy
    Sudmeier, L. J.
    Rosenberg, S. A.
    Wallace, C. R.
    Das, R. K.
    Anderson, B. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E26 - E26
  • [40] Dose gradient impact on biological equivalent dose for accelerated partial breast irradiation using high dose rate interstitial brachytherapy
    Ferre, M.
    Courdi, A.
    Hannoun, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S526 - S526