Detection of Abrin Using a Polyrnide-based Piezoresistive Microcantilever Biosensor

被引:0
|
作者
Wang, Yang [1 ]
Tian, Yuan [1 ]
Yu, Xiaomei [1 ]
机构
[1] Peking Univ, Inst Microelect, Natl Key Lab Sci & Technol Micro Nano Fabricat, Beijing 100871, Peoples R China
来源
2018 14TH IEEE INTERNATIONAL CONFERENCE ON SOLID-STATE AND INTEGRATED CIRCUIT TECHNOLOGY (ICSICT) | 2018年
关键词
LABEL-FREE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Although the traditional silicon-based microcantilever working with intrinsic piezoresistive effect has high sensitivity, it is easier to be broken in practical application because of its high elastic modulus. In this paper, we develop a piezoresistive microcantilever with a flexible polymide (PI) layer, whose Young's modulus is only about one-tenth of silicon oxide, as the top insulator of the single-crystalline silicon piezoresistor. The polymide-based piezoresistive microcantilever was fabricated on a SOI wafer and the experimental output voltage fluctuation of the fabricated microcantilevers in the phosphate buffered saline (PBS) solution is within 2 V at 3V bias voltage supply. Finally, a sensitive detection of abrin toxin was realized with a limit of detection of 30ng/mL (0.01M) by modifying the anti-abrin PcAb on the top gold surface of the microcantilever. Due to the fact that the fabrication process is compatible with CMOS, it provides a promising possibility to monolithically integrate the piezoresistive microcantilever biosensor with SOT CMOS circuits.
引用
收藏
页码:696 / 698
页数:3
相关论文
共 50 条
  • [21] Piezoresistive microcantilever based lab-on-a-chip system for detection of macronutrients in the soil
    Patkar, Rajul S.
    Ashwin, Mamta
    Rao, V. Ramgopal
    SOLID-STATE ELECTRONICS, 2017, 138 : 94 - 100
  • [22] Piezoresistive microcantilever optimization for uncooled infrared detection technology
    Rajic, S
    Evans, BM
    Datskos, PG
    Oden, PI
    Thundat, T
    Egert, CM
    INFRARED SPACEBORNE REMOTE SENSING IV, 1996, 2817 : 179 - 186
  • [23] Uncooled thermal imaging using a piezoresistive microcantilever
    Oden, PI
    Datskos, PG
    Thundat, T
    Warmack, RJ
    APPLIED PHYSICS LETTERS, 1996, 69 (21) : 3277 - 3279
  • [24] An Instrumentation Design for Microsignal Output from Piezoresistive Microcantilever Biosensor for Human Stress
    Khuan, Lee Yoot
    Abdullah, Mohd Firdaus
    Ismail, Mohd Ismarul A.
    Humid, Abdul Razak M. S.
    Rustam, Ilham
    Bujang, Maureen S. A.
    Madzhi, Nina Korlina
    Ahmad, Anuar
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 74 - 77
  • [25] Piezoresistive microcantilever aptasensor for ricin detection and kinetic analysis
    Liu, Zhi-Wei
    Tong, Zhao-Yang
    Liu, Bing
    Hao, Lan-Qun
    Mu, Xi-Hui
    Zhang, Jin-Ping
    Gao, Chuan
    AIP ADVANCES, 2015, 5 (04):
  • [26] A piezoresistive bridge-microcantilever biosensor by CMOS process for surface stress measurement
    Yang, S. M.
    Chang, C.
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 145 (01): : 405 - 410
  • [27] Piezo-resistive method for tuberculosis detection using microcantilever biosensor
    Sneha Dhakane
    W. V. Patil
    Microsystem Technologies, 2014, 20 : 457 - 462
  • [28] Piezo-resistive method for tuberculosis detection using microcantilever biosensor
    Dhakane, Sneha
    Patil, W. V.
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2014, 20 (03): : 457 - 462
  • [29] Microcantilever Based Dual Mode Optical Biosensor For Agricultural Pathogen Detection
    Patkar, Rajul
    Ashwin, Mamta
    Vinchurkar, Madhuri
    Adami, Andrea
    Giacomozzi, Flavio
    Lorenzelli, Leandro
    Baghini, M. Shojaei
    Rao, V. Ramgopal
    2018 IEEE SENSORS, 2018, : 1671 - 1673
  • [30] Aptamer-based microcantilever-array biosensor for profenofos detection
    Li, Chao
    Zhang, Guangping
    Wu, Shangquan
    Zhang, Qingchuan
    ANALYTICA CHIMICA ACTA, 2018, 1020 : 116 - 122