Selective label-free electrochemical impedance measurement of glycated haemoglobin on 3-aminophenylboronic acid-modified eggshell membranes

被引:11
|
作者
Boonyasit, Yuwadee [1 ]
Heiskanen, Arto [2 ]
Chailapakul, Orawan [3 ,4 ]
Laiwattanapaisal, Wanida [5 ]
机构
[1] Chulalongkorn Univ, Fac Allied Hlth Sci, Grad Program Clin Biochem & Mol Med, Bangkok 10330, Thailand
[2] Tech Univ Denmark, Dept Micro & Nanotechnol, DK-2800 Lyngby, Denmark
[3] Chulalongkorn Univ, Dept Chem, EOSRU, Fac Sci, Bangkok 10330, Thailand
[4] Chulalongkorn Univ, Ctr Excellence Petrochem & Mat Technol PETROMAT, Bangkok 10330, Thailand
[5] Chulalongkorn Univ, Fac Allied Hlth Sci, Dept Clin Chem, Bangkok 10330, Thailand
关键词
Glycated haemoglobin (HbA1c); Diabetes mellitus; 3-aminophenyl boronic acid; Eggshell membrane; Membrane-based biosensor; Selective label-free electrochemical detection; IFCC REFERENCE METHOD; ALUMINA MEMBRANE; BIOSENSOR; HBA(1C); IMMOBILIZATION; BINDING; GLUCOSE; INTERFERENCE; FABRICATION; ELECTRODES;
D O I
10.1007/s00216-015-8680-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We propose a novel alternative approach to long-term glycaemic monitoring using eggshell membranes (ESMs) as a new immobilising platform for the selective label-free electrochemical sensing of glycated haemoglobin (HbA1c), a vital clinical index of the glycaemic status in diabetic individuals. Due to the unique features of a novel 3-aminophenylboronic acid-modified ESM, selective binding was obtained via cis-diol interactions. This newly developed device provides clinical applicability as an affinity membrane-based biosensor for the identification of HbA1c over a clinically relevant range (2.3 - 14 %) with a detection limit of 0.19 %. The proposed membrane-based biosensor also exhibited good reproducibility. When analysing normal and abnormal HbA1c levels, the within-run coefficients of variation were 1.68 and 1.83 %, respectively. The run-to-run coefficients of variation were 1.97 and 2.02 %, respectively. These results demonstrated that this method achieved the precise and selective measurement of HbA1c. Compared with a commercial HbA1c kit, the results demonstrated excellent agreement between the techniques (n = 15), demonstrating the clinical applicability of this sensor for monitoring glycaemic control. Thus, this low-cost sensing platform using the proposed membrane-based biosensor is ideal for point-of-care diagnostics.
引用
收藏
页码:5287 / 5297
页数:11
相关论文
共 50 条
  • [21] Label-free and label based electrochemical detection of hybridization by using methylene blue and peptide nucleic acid probes at chitosan modified carbon paste electrodes
    Kara, P
    Kerman, K
    Ozkan, D
    Meric, B
    Erdem, A
    Nielsen, PE
    Ozsoz, M
    ELECTROANALYSIS, 2002, 14 (24) : 1685 - 1690
  • [22] Highly Sensitive Electrochemical Impedance- Based Biosensor for Label-Free and Wide Range Detection of Fibrinogen Using Hydrothermally Grown AlFeO3 Nanospheres Modified Electrode
    Durai, Lignesh
    Badhulika, Sushmee
    IEEE SENSORS JOURNAL, 2021, 21 (04) : 4160 - 4166
  • [23] Voltammetric behavior of uric acid on carbon paste electrode modified with salmon sperm dsDNA and its application as label-free electrochemical sensor
    Mohamadi, Maryam
    Mostafavi, Ali
    Torkzadeh-Mahani, Masoud
    BIOSENSORS & BIOELECTRONICS, 2014, 54 : 211 - 216
  • [24] Immobilization and hybridization of DNA based on magnesium ion modified 2,6-pyridinedicarboxylic acid polymer and its application for label-free PAT gene fragment detection by electrochemical impedance spectroscopy
    Jiao Kui
    Yang Tao
    Yang Jie
    Feng YuanYuan
    SCIENCE IN CHINA SERIES B-CHEMISTRY, 2007, 50 (04): : 538 - 546
  • [25] Immobilization and hybridization of DNA based on magnesium ion modified 2,6-pyridinedicarboxylic acid polymer and its application for label-free PAT gene fragment detection by electrochemical impedance spectroscopy
    Kui Jiao
    Tao Yang
    Jie Yang
    YuanYuan Feng
    Science in China Series B: Chemistry, 2007, 50 : 538 - 546
  • [27] A label-free electrochemical impedance immunosensor based on AuNPs/PAMAM-MWCNT-Chi nanocomposite modified glassy carbon electrode for detection of Salmonella typhimurium in milk
    Dong, Jing
    Zhao, Han
    Xu, Minrong
    Ma, Qiang
    Ai, Shiyun
    FOOD CHEMISTRY, 2013, 141 (03) : 1980 - 1986
  • [28] Electrochemical Deoxyribonucleic Acid Biosensor Based on Multiwalled Carbon Nanotubes/Ag-TiO2 Composite Film for Label-Free Phosphinothricin Acetyltransferase Gene Detection by Electrochemical Impedance Spectroscopy
    Zhou Na
    Yang Tao
    Jiao Kui
    Song Cai-xia
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (03) : 301 - 306
  • [29] Graphene-promoted 3,4,9,10-perylenetetracarboxylic acid nanocomposite as redox probe in label-free electrochemical aptasensor
    Yuan, Yali
    Gou, Xuxu
    Yuan, Ruo
    Chai, Yaqin
    Zhuo, Ying
    Ye, Xiaoya
    Gan, Xianxue
    BIOSENSORS & BIOELECTRONICS, 2011, 30 (01): : 123 - 127
  • [30] Development and modeling of an ultrasensitive label-free electrochemical immunosensor for okadaic acid based on polythionine-modified three-dimensional gold nanoelectrode ensembles
    Li, Rujin
    Cao, Lixin
    Liang, Chenxi
    Sun, Shuai
    Liu, Haiping
    Yan, Peisheng
    IONICS, 2020, 26 (09) : 4661 - 4670