Comparison of Radiation-Induced Secondary Malignancy Risk Between Sequential and Simultaneous Integrated Boost for the Treatment of Nasopharyngeal Carcinoma: Intensity-Modulated Radiotherapy versus Volumetric-Modulated Arc Therapy

被引:1
|
作者
Haciislamoglu, Emel [1 ]
Cinar, Yunus [2 ]
Eren, Mehmet [2 ]
Canyilmaz, Emine [1 ]
Gurcan, Fatih [3 ]
Serdar, Lasif [4 ]
Yoney, Adnan [1 ]
机构
[1] Karadeniz Tech Univ, Fac Med, Dept Radiat Oncol, Trabzon, Turkey
[2] Recep Tayyip Erdogan Univ, Fac Med, Dept Radiat Oncol, Rize, Turkey
[3] Karadeniz Tech Univ, Fac Engn, Dept Comp Engn, Trabzon, Turkey
[4] Kanuni Res & Educ Hosp, Dept Radiat Oncol, Trabzon, Turkey
来源
关键词
excess absolute risk; intensity-modulated radiotherapy; organ equivalent dose; secondary cancer risk; volumetric-modulated arc therapy; INDUCED CANCER; NECK-CANCER; IMRT; VMAT; DELIVERY; IMPACT; HEAD;
D O I
10.2147/CMAR.S244901
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This study aimed to compare the secondary cancer risk (SCR) between the sequential boost (SEQ) technique and simultaneous integrated boost (SIB) technique in intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) in patients with nasopharyngeal carcinoma (NPC) using the concepts of organ equivalent dose (OED) and excess absolute risk (EAR). Patients and Methods: IMRT-SEQ, VMAT-SEQ, IMRT-SIB, and VMAT-SIB plans were created with identical objective functions for five patients with early-stage NPC. Three different planning tumor volumes (PTVs; PTV1, PTV2, and PTV3) were delineated for each patient, and the prescribed doses were 50 Gy, 60 Gy, and 70 Gy (2 Gy/fraction), respectively, for the SEQ technique and 52.8 Gy, 59.4 Gy, and 69.3 Gy (33 fractions), respectively, for the SIB technique. Results: All plans were clinically acceptable. There was no difference in most OED-based SCRs between IMRT and VMAT when the same fractionation scheme was used. Compared with the SEQ technique, the SIB technique in IMRT and VMAT was associated with the lowest OEDs for the oral cavity, pharynx, parotids, and submandibular glands, resulting in SCR reduction. SCR for the parotids was much lower than that for the other assessed organs when the SIB technique was used. Conclusion: Our findings suggest that OED-based SCRs are lower with the SIB technique than with the SEQ technique in IMRT and VMAT in most organs for which SCR was calculated; furthermore, SCR for the parotids is much lower than that for other organs when the SIB technique is used in patients with NPC.
引用
收藏
页码:2513 / 2521
页数:9
相关论文
共 50 条
  • [31] Breast Conformal Radiotherapy with Sequential Boost Versus Intensity-Modulated Radiation Therapy with a Simultaneously Integrated Boost
    Komisopoulos, G.
    Mavroidis, P.
    Simopoulou, F.
    Kyrgias, G.
    Papanikolaou, N.
    Theodorou, K.
    MEDICAL PHYSICS, 2022, 49 (06) : E913 - E913
  • [32] VOLUMETRIC ARC INTENSITY-MODULATED THERAPY FOR SPINE BODY RADIOTHERAPY: COMPARISON WITH STATIC INTENSITY-MODULATED TREATMENT
    Wu, Q. Jackie
    Yoo, Sua
    Kirkpatrick, John P.
    Thongphiew, Danthai
    Yin, Fang-Fang
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (05): : 1596 - 1604
  • [33] Intensity-modulated radiotherapy for nasopharyngeal carcinoma: the reduction of radiation-induced trismus
    Hsiung, C-Y
    Huang, E-Y
    Ting, H-M
    Huang, H-Y
    BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (970): : 809 - 814
  • [34] Volumetric-modulated Arc Therapy in Head and Neck Radiotherapy: A Planning Comparison using Simultaneous Integrated Boost for Nasopharynx and Oropharynx Carcinoma
    Johnston, M.
    Clifford, S.
    Bromley, R.
    Back, M.
    Oliver, L.
    Eade, T.
    CLINICAL ONCOLOGY, 2011, 23 (08) : 503 - 511
  • [35] Single arc volumetric-modulated arc therapy is sufficient for nasopharyngeal carcinoma: a dosimetric comparison with dual arc VMAT and dynamic MLC and step-and-shoot intensity-modulated radiotherapy
    Zhong-Hua Ning
    Jin-Ming Mu
    Jian-Xue Jin
    Xiao-Dong Li
    Qi-Lin Li
    Wen-Dong Gu
    Jin Huang
    Yang Han
    Hong-Lei Pei
    Radiation Oncology, 8
  • [36] Dosimetric Comparison of Intensity-Modulated Radiation Therapy and Volumetric Modulated Arc Therapy in Craniospinal Radiotherapy of Childhood
    Ozer, Elif Eda
    Coban, Yasin
    Cifter, Fulya
    Karacam, Songul
    Uzel, Omer
    Turkan, Tahir Sedat
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2021, 36 (01): : 96 - 103
  • [37] Single arc volumetric-modulated arc therapy is sufficient for nasopharyngeal carcinoma: a dosimetric comparison with dual arc VMAT and dynamic MLC and step-and-shoot intensity-modulated radiotherapy
    Ning, Zhong-Hua
    Mu, Jin-Ming
    Jin, Jian-Xue
    Li, Xiao-Dong
    Li, Qi-Lin
    Gu, Wen-Dong
    Huang, Jin
    Han, Yang
    Pei, Hong-Lei
    RADIATION ONCOLOGY, 2013, 8
  • [38] Intensity-modulated proton therapy versus volumetric-modulated ARC therapy in patients with nasopharyngeal carcinoma: A long-term, multicenter cohort study
    Wu, Ching-Nung
    Wang, Jung-Der
    Chen, Wei-Chih
    Lin, Chung-Ying
    Chiu, Tai-Jan
    Yang, Yao-Hsu
    Chang, Joseph Tung-Chieh
    Luo, Sheng-Dean
    Wang, Yu-Ming
    RADIOTHERAPY AND ONCOLOGY, 2025, 202
  • [39] Different Risk Target Volumes for Nasopharyngeal Carcinoma Treated with Simultaneous Integrated Boost Intensity-Modulated Radiotherapy
    Wang, Fangzheng
    Jiang, Chuner
    Wang, Lei
    Yan, Fengqin
    Piao, Yongfeng
    Ye, Zhimin
    Xu, Min
    Liu, Jiping
    Fu, Zhenfu
    Jiang, Yangming
    JOURNAL OF CANCER, 2020, 11 (17): : 5210 - 5222
  • [40] Dosimetric comparison between step-shoot intensity-modulated radiotherapy and volumetric-modulated arc therapy for upper thoracic and cervical esophageal carcinoma
    Gao, Min
    Li, Qilin
    Ning, Zhonghua
    Gu, Wendong
    Huang, Jin
    Mu, Jinming
    Pei, Honglei
    MEDICAL DOSIMETRY, 2016, 41 (02) : 131 - 135