Comparison of Radiation-Induced Secondary Malignancy Risk Between Sequential and Simultaneous Integrated Boost for the Treatment of Nasopharyngeal Carcinoma: Intensity-Modulated Radiotherapy versus Volumetric-Modulated Arc Therapy

被引:1
|
作者
Haciislamoglu, Emel [1 ]
Cinar, Yunus [2 ]
Eren, Mehmet [2 ]
Canyilmaz, Emine [1 ]
Gurcan, Fatih [3 ]
Serdar, Lasif [4 ]
Yoney, Adnan [1 ]
机构
[1] Karadeniz Tech Univ, Fac Med, Dept Radiat Oncol, Trabzon, Turkey
[2] Recep Tayyip Erdogan Univ, Fac Med, Dept Radiat Oncol, Rize, Turkey
[3] Karadeniz Tech Univ, Fac Engn, Dept Comp Engn, Trabzon, Turkey
[4] Kanuni Res & Educ Hosp, Dept Radiat Oncol, Trabzon, Turkey
来源
关键词
excess absolute risk; intensity-modulated radiotherapy; organ equivalent dose; secondary cancer risk; volumetric-modulated arc therapy; INDUCED CANCER; NECK-CANCER; IMRT; VMAT; DELIVERY; IMPACT; HEAD;
D O I
10.2147/CMAR.S244901
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This study aimed to compare the secondary cancer risk (SCR) between the sequential boost (SEQ) technique and simultaneous integrated boost (SIB) technique in intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) in patients with nasopharyngeal carcinoma (NPC) using the concepts of organ equivalent dose (OED) and excess absolute risk (EAR). Patients and Methods: IMRT-SEQ, VMAT-SEQ, IMRT-SIB, and VMAT-SIB plans were created with identical objective functions for five patients with early-stage NPC. Three different planning tumor volumes (PTVs; PTV1, PTV2, and PTV3) were delineated for each patient, and the prescribed doses were 50 Gy, 60 Gy, and 70 Gy (2 Gy/fraction), respectively, for the SEQ technique and 52.8 Gy, 59.4 Gy, and 69.3 Gy (33 fractions), respectively, for the SIB technique. Results: All plans were clinically acceptable. There was no difference in most OED-based SCRs between IMRT and VMAT when the same fractionation scheme was used. Compared with the SEQ technique, the SIB technique in IMRT and VMAT was associated with the lowest OEDs for the oral cavity, pharynx, parotids, and submandibular glands, resulting in SCR reduction. SCR for the parotids was much lower than that for the other assessed organs when the SIB technique was used. Conclusion: Our findings suggest that OED-based SCRs are lower with the SIB technique than with the SEQ technique in IMRT and VMAT in most organs for which SCR was calculated; furthermore, SCR for the parotids is much lower than that for other organs when the SIB technique is used in patients with NPC.
引用
收藏
页码:2513 / 2521
页数:9
相关论文
共 50 条
  • [1] Simultaneous integrated boost (SIB) for treatment of gynecologic carcinoma: Intensity-modulated radiation therapy (IMRT) vs volumetric-modulated arc therapy (VMAT) radiotherapy
    Vergalasova, Irina
    Light, Kim
    Chino, Junzo
    Craciunescu, Oana
    MEDICAL DOSIMETRY, 2017, 42 (03) : 230 - 237
  • [2] Comparison of Intensity-Modulated Arc Therapy and Intensity-Modulated Radiotherapy Plans for Nasopharyngeal Carcinoma Simultaneously Integrated Boost Radiation Therapy
    Liu, T.
    Bai, T.
    Chen, J.
    Zhang, G.
    Ma, C.
    Yin, Y.
    Lin, X.
    EUROPEAN JOURNAL OF CANCER, 2011, 47 : S563 - S563
  • [3] Comparison of Intensity-Modulated Arc Therapy and Intensity-Modulated Radiotherapy Plans for Nasopharyngeal Carcinoma Simultaneously Integrated Boost Radiation Therapy
    Liu, T.
    Yin, Y.
    Bai, T.
    Chen, J.
    Lu, J.
    Sun, T.
    Gao, M.
    Ma, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [4] Dual Arc Volumetric-modulated Arc Radiotherapy (VMAT) of Nasopharyngeal Carcinomas: A Simultaneous Integrated Boost Treatment Plan Comparison with Intensity-modulated Radiotherapies and Single Arc VMAT
    Lee, T. -F.
    Ting, H. -M.
    Chao, R-J.
    Fang, F. -M.
    CLINICAL ONCOLOGY, 2012, 24 (03) : 196 - 207
  • [5] Dosimetric analysis and comparison of volumetric-modulated arc therapy versus intensity-modulated radiation therapy for liver carcinoma
    Chiang, Bing-Hao
    Schnell, Erich
    Hibbitts, Kerry
    Herman, Terence
    Ahmad, Salahuddin
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 138 - 140
  • [6] Intensity-modulated radiotherapy, coplanar volumetric-modulated arc, therapy, and noncoplanar volumetric-modulated arc therapy in, glioblastoma: A dosimetric comparison
    Hou, Yong
    Zhang, Yan
    Liu, Zhen
    Yv, Lili
    Liu, Kun
    Tian, Xiufang
    Lv, Yajuan
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2019, 187
  • [7] Comparison of dosimetric benefits in nasopharyngeal carcinoma patients among intensity-modulated radiotherapy, volumetric-modulated arc therapy and tomotherapy
    Xiong, W.
    Guoqiang, X.
    Wang, Q.
    Xu, T.
    Cao, R.
    Zhu, L.
    ANNALS OF ONCOLOGY, 2021, 32 : S793 - S793
  • [8] Comparison of sequential versus simultaneous integrated boost of volumetric modulated arc therapy in treatment of oropharyngeal carcinoma
    Kachhwaha, Avni
    Tiwari, Ramakant
    Gayen, Sanjib
    Manna, Sumanta
    Solanki, Akanksha
    Devnani, Bharti
    Pareek, Puneet
    CANCER TREATMENT AND RESEARCH COMMUNICATIONS, 2023, 36
  • [9] Quality of life and survival outcome for patients with nasopharyngeal carcinoma treated by volumetric-modulated arc therapy versus intensity-modulated radiotherapy
    Huang, Tai-Lin
    Tsai, Ming-Hsien
    Chuang, Hui-Ching
    Chien, Chih-Yen
    Lin, Yu-Tsai
    Tsai, Wen-Ling
    Fang, Fu-Min
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [10] Quality of life and survival outcome for patients with nasopharyngeal carcinoma treated by volumetric-modulated arc therapy versus intensity-modulated radiotherapy
    Tai-Lin Huang
    Ming-Hsien Tsai
    Hui-Ching Chuang
    Chih-Yen Chien
    Yu-Tsai Lin
    Wen-Ling Tsai
    Fu-Min Fang
    Radiation Oncology, 15