A new direct air-cooled single-effect LiBr-H2O absorption prototype is described and proposed for use in solar cooling. As distinguishing aspects, it presents: an adiabatic absorber using flat-fan sheets: an air-cooling system that directly refrigerates both the condenser and the absorber and; the possibility of being operated also as a double-effect unit. A solar facility comprising a 48 m(2) field of flat-plate collectors was used to test the single-effect operation mode of the prototype. Results from an experimental campaign carried out in Madrid during summer 2010 are shown and operation parameters corresponding to two typical summer days are detailed. The prototype worked efficiently, with COP values around 0.6. Cooling power varied from 2 kW to 3.8 kW, which represented about 85% of the prototype's nominal capacity. Chilled water temperatures mostly ranged between 14 degrees C and 16 degrees C, although the lowest measured value was of 12.8 degrees C. Condensation and absorption temperatures were under 50 degrees C and 46 degrees C, respectively, even with outdoor temperatures of 40 degrees C. Driving water temperature ranged between 85 degrees C and 110 degrees C. As a mean, the system was able to meet 65% of the cooling demand corresponding to a room of 40 m(2). No signs of crystallization were observed during about a hundred hours of operation. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3358 / 3368
页数:11
相关论文
共 50 条
  • [21] Comparison of absorption refrigeration cycles for efficient air-cooled solar cooling
    Xu, Z. Y.
    Wang, R. Z.
    SOLAR ENERGY, 2018, 172 : 14 - 23
  • [22] Theoretical Study on Solar-driven Air-cooled LiBr/Water Absorption Refrigeration System
    Zhao, Dandan
    Hu, Hongbo
    Wan, Luchun
    Zhang, Baohuai
    PROGRESS IN RENEWABLE AND SUSTAINABLE ENERGY, PTS 1 AND 2, 2013, 608-609 : 3 - 10
  • [23] The experimental characterization of a lithium bromide-water absorption chiller and the development of a calibrated model
    Beausoleil-Morrison, Ian
    Johnson, Geoffrey
    Kemery, Briana Paige
    SOLAR ENERGY, 2015, 122 : 368 - 381
  • [24] Experimental evaluation of a new mini square channel air-cooled heat exchanger for an absorption chiller
    Venegas, M.
    Ghatos, S.
    de Vega, M.
    Garcia-Hernando, N.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2022, 195
  • [25] Simulation of solar lithium bromide-water absorption cooling system with parabolic trough collector
    Mazloumi, M.
    Naghashzadegan, M.
    Javaherdeh, K.
    ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (10) : 2820 - 2832
  • [26] Performance characteristics of a solar driven lithium bromide-water absorption chiller integrated with absorption energy storage
    Ibrahim, Nasiru I.
    Al-Sulaiman, Fahad A.
    Ani, Farid Nasir
    ENERGY CONVERSION AND MANAGEMENT, 2017, 150 : 188 - 200
  • [27] Research on increasing the gas turbine generating capacity by intake air cooling using a lithium bromide-water absorption system
    Jiang, Zhoushu
    Hu, Yacai
    Tu, Chuanjiang
    Tu, Jin
    Dongli Gongcheng/Power Engineering, 1999, 19 (04): : 300 - 304
  • [28] Performance evaluation for direct air-cooled steam condensers in power plant
    Yang, Li-Jun
    Du, Xiao-Ze
    Yang, Yong-Ping
    Liu, Deng-Ying
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2007, 27 (02): : 59 - 63
  • [29] The experimental investigation on the plastic heat exchanger applied in Lithium Bromide-Water absorption chillers
    Zhang, X. B.
    Hu, Y. C.
    Yu, Z. T.
    Li, W.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 366 - 370
  • [30] Performance of air-cooled absorption air-conditioning systems working with water-(LiBr plus LiI+LiNO3+LiCl)
    Bourouis, M
    Vallès, M
    Medrano, M
    Coronas, A
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2005, 219 (E2) : 205 - 213