Line-ratio based ring artifact correction method using transfer function

被引:6
|
作者
Oh, Daejoong [1 ]
Hwang, Dosik [1 ]
Kim, Younguk [1 ]
机构
[1] Yonsei Univ, Sch Elect & Elect Engn, 50 Yonsei Ro, Seoul 03722, South Korea
来源
MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING | 2016年 / 9783卷
关键词
Computed Tomography; Ring artifact;
D O I
10.1117/12.2217113
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Computed tomography (CT) has been used for medical purposes. However there are many artifacts at CT images and that makes distorted image. Ring artifact is caused by non-uniform sensitivity of detectors and makes ring shape artifact. Line-ratio method was proposed to solve the problem however there are some problem at specific case. Therefore we propose advanced method to correct ring artifact using transfer function. As a result, ring artifacts can be removed at more global cases. Simulation data shows the proposed method outperforms the conventional line-ratio method.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Ring artifact and non-uniformity correction method for improving XACT imaging
    Eldib, Mohamed Elsayed
    Wang, Siqi
    Xiang, Liangzhong
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [22] Off-line- and on-line-monitoring of power transformers using the transfer function method
    Leibfried, T
    Feser, K
    CONFERENCE RECORD OF THE 1996 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1996, : 34 - 37
  • [23] Streak artifact reduction in filtered backprojection using a level line-based interpolation method
    Bruyant, PP
    Sau, J
    Mallet, JJ
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (11) : 1913 - 1919
  • [24] Sparsity-based method for ring artifact elimination in computed tomography
    Selim, Mona
    Rashed, Essam A.
    Atiea, Mohammed A.
    Kudo, Hiroyuki
    PLOS ONE, 2022, 17 (06):
  • [25] Accelerating Ring Artifact Correction for Flat-Detector CT using the CUDA Framework
    Chen, W.
    Prell, D.
    Kyriakou, Y.
    Kalender, W. A.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [26] Measurement of the electron density in atmospheric-pressure low-temperature argon discharges by line-ratio method of optical emission spectroscopy
    Zhu, X. M.
    Pu, Y. K.
    Balcon, N.
    Boswell, R.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2009, 42 (14)
  • [27] Artifact correction of the ongoing EEG using spatial filters based on artifact and brain signal topographies
    Ille, N
    Berg, P
    Scherg, M
    JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2002, 19 (02) : 113 - 124
  • [28] A novel method of computation of transfer function of unknown networks for indoor power line communication Transfer function estimation of power line using transmission matrices
    Tiru, Banty
    2014 IEEE SYMPOSIUM ON COMPUTATIONAL INTELLIGENCE FOR COMMUNICATION SYSTEMS AND NETWORKS (CICOMMS), 2014, : 69 - 75
  • [29] Optical emission spectroscopy in low-temperature plasmas containing argon and nitrogen: determination of the electron temperature and density by the line-ratio method
    Zhu, Xi-Ming
    Pu, Yi-Kang
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2010, 43 (40)
  • [30] Determination of metastable level densities in a low-pressure inductively coupled argon plasma by the line-ratio method of optical emission spectroscopy
    Lee, Young-Kwang
    Moon, Se-Youn
    Oh, Se-Jin
    Chung, Chin-Wook
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2011, 44 (28)