Evaluation of the rapid diagnostic test SDFK40 (Pf-pLDH/pan-pLDH) for the diagnosis of malaria in a non-endemic setting

被引:26
|
作者
Maltha, Jessica [1 ,2 ]
Gillet, Philippe [2 ]
Cnops, Lieselotte [2 ]
Bottieau, Emmanuel [2 ]
Van Esbroeck, Marjan [2 ]
Bruggeman, Cathrien [3 ,4 ]
Jacobs, Jan [1 ,2 ]
机构
[1] Med & Life Sci FHML, Fac Hlth, Maastricht, Netherlands
[2] Inst Trop Med ITM, Dept Clin Sci, Unit Trop Lab Med, Antwerp, Belgium
[3] Maastricht Infect Ctr, Sch Publ Hlth & Primary Care, Dept Med Microbiol, Maastricht, Netherlands
[4] Maastricht Univ, Med Ctr, CAPHRI, Maastricht, Netherlands
来源
MALARIA JOURNAL | 2011年 / 10卷
关键词
PARASITE LACTATE-DEHYDROGENASE; EXPERT MICROSCOPY; FIELD; PERFORMANCE; ACCURACY; AREA;
D O I
10.1186/1475-2875-10-7
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: The present study evaluated the SD Bioline Malaria Ag 05FK40 (SDFK40), a three-band RDT detecting Plasmodium falciparum-specific parasite lactate dehydrogenase (Pf-pLDH) and pan Plasmodium-specific pLDH (pan-pLDH), in a reference setting. Methods: The SDFK40 was retrospectively and prospectively tested against a panel of stored (n = 341) and fresh (n = 181) whole blood samples obtained in international travelers suspected of malaria, representing the four Plasmodium species as well as Plasmodium negative samples, and compared to microscopy and PCR results. The prospective panel was run together with OptiMAL (Pf-pLDH/pan-pLDH) and SDFK60 (histidine-rich protein-2 (HRP-2)/pan-pLDH). Results: Overall sensitivities for P. falciparum tested retrospectively and prospectively were 67.9% and 78.8%, reaching 100% and 94.6% at parasite densities >1,000/mu l. Sensitivity at parasite densities <= 100/mu l was 9.1%. Overall sensitivities for Plasmodium vivax and Plasmodium ovale were 86.7% and 80.0% (retrospectively) and 92.9% and 76.9% (prospectively), reaching 94.7% for both species (retrospective panel) at parasite densities >500/mu l. Sensitivity for Plasmodium malariae was 21.4%. Species mismatch occurred in 0.7% of samples (3/411) and was limited to non-falciparum species erroneously identified as P. falciparum. None of the Plasmodium negative samples in the retrospective panel reacted positive. Compared to OptiMAL and SDFK60, SDFK40 showed lower sensitivities for P. falciparum, but better detection of P. ovale. Inter-observer agreement and test reproducibility were excellent, but lot-to-lot variability was observed for pan-pLDH results in case of P. falciparum. Conclusion: SDFK40 performance was poor at low (<= 100/mu l) parasite densities, precluding its use as the only diagnostic tool for malaria diagnosis. SDFK40 performed excellent for P. falciparum samples at high (> 1,000/mu l) parasite densities as well as for detection of P. vivax and P. ovale at parasite densities > 500/mu l.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Evaluation of the Immunoquick+4 malaria rapid diagnostic test in a non-endemic setting
    D. P. J. van Dijk
    P. Gillet
    E. Vlieghe
    L. Cnops
    M. Van Esbroeck
    J. Jacobs
    European Journal of Clinical Microbiology & Infectious Diseases, 2010, 29 : 577 - 583
  • [22] Evaluation of CareStart™ Malaria HRP2/pLDH (Pf/pan) Combo Test in a malaria low transmission region of Senegal
    Diallo, Mamadou Alpha
    Diongue, Khadim
    Ndiaye, Mouhamadou
    Gaye, Amy
    Deme, Awa
    Badiane, Aida S.
    Ndiaye, Daouda
    MALARIA JOURNAL, 2017, 16 : 328
  • [23] Evaluation of the OnSite (Pf/Pan) rapid diagnostic test for diagnosis of clinical malaria
    Abu Naser Mohon
    Rubayet Elahi
    Milka Patracia Podder
    Khaja Mohiuddin
    Mohammad Sharif Hossain
    Wasif A Khan
    Rashidul Haque
    Mohammad Shafiul Alam
    Malaria Journal, 11
  • [24] Evaluation of the OnSite (Pf/Pan) rapid diagnostic test for diagnosis of clinical malaria
    Mohon, Abu Naser
    Elahi, Rubayet
    Podder, Milka Patracia
    Mohiuddin, Khaja
    Hossain, Mohammad Sharif
    Khan, Wasif A.
    Haque, Rashidul
    Alam, Mohammad Shafiul
    MALARIA JOURNAL, 2012, 11
  • [25] Evaluation of CareStart™ Malaria HRP2/pLDH (Pf/pan) Combo Test in a malaria low transmission region of Senegal
    Mamadou Alpha Diallo
    Khadim Diongue
    Mouhamadou Ndiaye
    Amy Gaye
    Awa Deme
    Aida S. Badiane
    Daouda Ndiaye
    Malaria Journal, 16
  • [26] Accuracy of Pf HRP2 versus Pf-pLDH antigen detection by malaria rapid diagnostic tests in hospitalized children in a seasonal hyperendemic malaria transmission area in Burkina Faso
    Jessica Maltha
    Issa Guiraud
    Palpouguini Lompo
    Bérenger Kaboré
    Philippe Gillet
    Chris Van Geet
    Halidou Tinto
    Jan Jacobs
    Malaria Journal, 13
  • [27] CROSS REACTION OF ANTI-<it>PLASMODIUM FALCIPARUM</it> PLDH ANTIBODIES WITH <it>PLASMODIUM MALARIAE</it> PLDH USING THE RAPID DIAGNOSTIC TEST SD BIOLINE MALARIA PF/PF/PV (05FK123)
    Di Santi, Silvia
    Lima, Giselle
    Inoue, Juliana
    Costa-Nascimento, Maria
    Farinas, Maria
    Sanchez, Maria
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2018, 99 (04): : 541 - 541
  • [28] CLINICAL IMPACT OF MALARIA RAPID DIAGNOSTIC TESTING IN A NON-ENDEMIC SETTING
    Enane, Leslie A.
    Ota-Sullivan, Kaede
    Feemster, Kristen A.
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2015, 93 (04): : 461 - 462
  • [29] Accuracy of PfHRP2 versus Pf-pLDH antigen detection by malaria rapid diagnostic tests in hospitalized children in a seasonal hyperendemic malaria transmission area in Burkina Faso
    Maltha, Jessica
    Guiraud, Issa
    Lompo, Palpouguini
    Kabore, Berenger
    Gillet, Philippe
    Van Geet, Chris
    Tinto, Halidou
    Jacobs, Jan
    MALARIA JOURNAL, 2014, 13
  • [30] Evaluation of the SD FK70 Malaria Ag Plasmodium vivax rapid diagnostic test in a non-endemic setting
    Philippe Gillet
    Katrien Bosselaers
    Lieselotte Cnops
    Emmanuel Bottieau
    Marjan Van Esbroeck
    Jan Jacobs
    Malaria Journal, 8