The air-conditioner system with a kind of waste heat recovery unit

被引:0
|
作者
Hu, XH [1 ]
Shu, SM [1 ]
机构
[1] Huazhong Univ Sci & Technol, Cryogen & Refrigerat Technol Teaching & Res Sect, Wuhan 430074, Hubei, Peoples R China
关键词
air-conditioner; waste heat recovery; performance analysis;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
A method has been used to utilize the waste heat of the air-conditioner system by transforming the equipment for condensation in this paper. In the new system, the reasonable flow style is adopted and the heating water can be generated by the energy in the cooling process of the compressor discharge which is a sort of low-level heat source. The advantage of this method is obvious because the waste heat of system itself can be utilized and the amount of the cooling water can be reduced (approximately 15%-47%accordimg to the different condensing temperature). This method can be applied to the multi-functional construction like the hotel that needs the chilled water and heating water simultaneously.
引用
收藏
页码:1063 / 1065
页数:3
相关论文
共 50 条
  • [31] Aerodynamic and aeroacoustic study of collateral axial flow fan system inside outdoor unit of air-conditioner
    Ouyang, Hua
    Tian, Jie
    Wu, Yadong
    Zheng, Zhiming
    Sumio, Shiochi
    Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering, 2007, 43 (10): : 215 - 220
  • [32] Enhanced condensation heat transfer in air-conditioner heat exchanger using superhydrophobic foils
    Wang, Shanlin
    Yu, Xinquan
    Liang, Caihua
    Zhang, Youfa
    APPLIED THERMAL ENGINEERING, 2018, 137 : 758 - 766
  • [33] HOME AIR-CONDITIONER WITH HUMAN DETECTOR
    KAWASHIMA, N
    IKEBOU, Y
    HOSONO, T
    NISHINAKA, N
    OZAKI, M
    MURAO, M
    FUJIMOTO, S
    SAKATA, S
    SHARP TECHNICAL JOURNAL, 1988, (40): : 143 - 145
  • [34] CUSTOM AIR-CONDITIONER FOR STORE USE
    TANAKA, T
    MORI, M
    SUGIURA, H
    TOSHIBA REVIEW, 1979, (121): : 41 - 48
  • [35] Effect of air-conditioner on fungal contamination
    Hamada, N
    Fujita, T
    ATMOSPHERIC ENVIRONMENT, 2002, 36 (35) : 5443 - 5448
  • [36] Microchannel evaporators of the residential air-conditioner
    Cho, Honggi
    Cho, Keumnam
    ICNMM2007: PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS, AND MINICHANNELS, 2007, : 625 - 630
  • [37] Hail effects on air-conditioner performance
    Sitzmann, Matthew J.
    Lu, Frank K.
    Smith, Steve R.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2007, VOL 6: ENERGY SYSTEMS: ANALYSIS, THERMODYNAMICS AND SUSTAINABILITY, 2008, : 869 - 876
  • [38] Noise control and sound quality evaluation of outdoor unit of split air-conditioner
    Wu, Chengjun
    Lei, Xiaofei
    JOURNAL OF MEASUREMENTS IN ENGINEERING, 2016, 4 (02) : 58 - 69
  • [39] Experimental Investigations on a Conventional Air-conditioner Working as Air-water Heat Pump
    Wang, Yu
    You, Yuwen
    Zhang, Zhigang
    PEEA 2011, 2011, 23
  • [40] Energy performance and thermal comfort of integrated energy recovery ventilator system with air-conditioner for passive buildings
    Cho, Wonhee
    Heo, Juneyeong
    Park, Myeong Hyeon
    Seo, Hyeong Joon
    Lee, Kisup
    Lee, Dong Gyu
    Kim, Yongchan
    ENERGY AND BUILDINGS, 2023, 295