The effect of humidity on gas sensing with ion mobility spectrometry

被引:34
|
作者
Borsdorf, Helko [1 ]
Fiedler, Petra [1 ]
Mayer, Thomas [1 ]
机构
[1] UFZ Helmholtz Ctr Environm Res Leipzig Halle, Dept Monitoring & Explorat Technol, D-4318 Leipzig, Germany
关键词
Field deployable sensor; Ion mobility spectrometry; Atmospheric pressure ionization; Effect of humidity; MEMBRANE INLET; PRESSURE; TEMPERATURE; CHROMATOGRAPHY; RESOLUTION; ANILINES;
D O I
10.1016/j.snb.2015.04.102
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Vaporized water molecules are unavoidable present in the ambient atmosphere and can considerably affect the analytical signals obtained with sensor techniques during real-time field measurements. Also the introduction of humidity into stand-alone ion mobility spectrometers cannot completely be avoided and the water vapor is transported via the carrier gas into spectrometer. For this case, we systematically investigated the way in which ion mobility measurements in positive mode are influenced. The drift times obtained with humid carrier gas are the same as those detected under dry conditions. They are constant over a range of water concentrations up to 2000 ppm. The nature of ions formed during the atmospheric chemical ionization processes is therefore independent on the humidity. However, the relative abundance of product ions can strongly be affected depending on the properties of substances investigated. While the signal intensity obtained for amines is comparatively unaffected by humidity, a significant decrease is observable for toluenes, chlorinated compounds and ketones. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:184 / 190
页数:7
相关论文
共 50 条
  • [21] Integration of gas-phase covalent ion/ion reactions with ion mobility spectrometry
    Carvalho, Veronica
    Keeling, Lyndon
    Webb, Ian
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [22] Application of Gas Chromatography-Ion Mobility Spectrometry in Aquaculture
    Jiang P.
    Liu Y.
    Zhang H.
    Shang S.
    Qi H.
    Dong X.
    Jin W.
    Journal of Chinese Institute of Food Science and Technology, 2023, 23 (06) : 431 - 440
  • [23] Gas-phase chiral separations by ion mobility spectrometry
    Dwivedi, Prabha
    Wu, Ching
    Matz, Laura M.
    Clowers, Brian H.
    Siems, William F.
    Hill, Herbert H., Jr.
    ANALYTICAL CHEMISTRY, 2006, 78 (24) : 8200 - 8206
  • [24] High Kinetic Energy Ion Mobility Spectrometer: Quantitative Analysis of Gas Mixtures with Ion Mobility Spectrometry
    Langejuergen, Jens
    Allers, Maria
    Oermann, Jens
    Kirk, Ansgar
    Zimmermann, Stefan
    ANALYTICAL CHEMISTRY, 2014, 86 (14) : 7023 - 7032
  • [25] Deprotonation effect of tetrahydrofuran-2-carbonitrile buffer gas dopant in ion mobility spectrometry
    Fernandez-Maestre, Roberto
    Meza-Morelos, Dairo
    Wu, Ching
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2016, 30 (11) : 1332 - 1338
  • [26] Laser-based ion mobility spectrometry for sensing of aromatic compounds
    Löhmannsröben, HG
    Beitz, T
    Laudien, R
    Schultze, R
    REMOTE SENSING IN ATMOSPHERIC POLLUTION MONITORING AND CONTROL, 2004, 5547 : 16 - 24
  • [27] Influences Of Air Humidity On Ion-Mobility-Spectrometry (ims) - Biomarkers In Human Breath
    Becher, G. R.
    Purkhart, R.
    Hillmann, A.
    Graupner, R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [28] Ion mobility spectrometry
    Zolotov, Yu.A.
    Journal of Analytical Chemistry, 2006, 61 (06):
  • [29] Ion mobility spectrometry
    Mayer, Thomas
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2014, 17 (3-4) : 103 - 104
  • [30] Ion mobility spectrometry
    Zolotov, Yu A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 61 (06) : 519 - 519