Porous ceramics as bone graft substitutes in long bone defects: A biomechanical, histological, and radiographic analysis

被引:186
|
作者
Johnson, KD
Frierson, KE
Keller, TS
Cook, C
Scheinberg, R
Zerwekh, J
Meyers, L
Sciadini, MF
机构
[1] UNIV VERMONT, DEPT MECH ENGN, BURLINGTON, VT USA
[2] UNIV TEXAS, SW MED CTR, DALLAS, TX USA
关键词
D O I
10.1002/jor.1100140304
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Three porous ceramic bone graft materials were compared with regard to their ability to heal a 2.5 cm defect created surgically in a bilateral canine radius model. The ceramic materials were analyzed at 12 and 24 weeks after surgery and included tricalcium phosphate, hydroxyapatite, and collagen hydroxyapatite, which contained a mixture of 35% tricalcium phosphate and 65% hydroxyapatite with added collagen. Each material was evaluated alone and with added bone marrow aspirate. All the implants were compared with a graft of autogenous cancellous bone in the contralateral radius. Biomechanical testing and radiographic evauation revealed that the addition of bone marrow aspirate was essential for tricalcium phosphate and hydroxyapatite to achieve results comparable with those of cancellous bone. Collagen hydroxyapatite performed well without the addition of bone marrow although the addition of marrow did have a positive effect. Further qualitative radiographic and histological analysis demonstrated that tricalcium phosphate was the only ceramic that showed any sign of degradation at 24 weeks. This observed degradation proved to be an important factor in evaluating radiographs because the radiodensity of collagen hydroxyapatite and hydroxyapatite interfered with the determination of radiographic union. At 24 weeks, tricalcium phosphate with bone marrow was the material that performed most like cancellous bone. In this study, the biomechanical and radiographic parameters of tricalcium phosphate with bone marrow were roughly comparable with those of cancellous bone at 12 and 24 weeks. Tricalcium phosphate was the only implant that showed significant evidence of degradation at 24 weeks by both histological and radiographic evaluations, and this degradation took place only after a degree of mechanical competence necessary for weight-bearing was achieved.
引用
收藏
页码:351 / 369
页数:19
相关论文
共 50 条
  • [41] Bone, grafts and bone graft substitutes in orthopedic trauma surgery - A critical analysis
    De Long, William G., Jr.
    Einhorn, Thomas A.
    Koval, Kenneth
    McKee, Michael
    Smith, Wade
    Sanders, Roy
    Watson, Tracy
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (03): : 649 - 658
  • [42] Comparing the osteogenic capacities of bone substitutes: Hydroxyapatite, high-density porous polyethylene, and bone collagen: A biochemical and histological analysis
    Bilkay, U
    Alper, M
    Celik, N
    Erdem, O
    Kerem, H
    Ozek, C
    Zekioglu, O
    Delen, Y
    Songur, E
    Cagdas, A
    JOURNAL OF CRANIOFACIAL SURGERY, 2004, 15 (04) : 585 - 593
  • [43] Bone-grafting and bone-graft substitutes
    Finkemeier, CG
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (03): : 454 - 464
  • [44] Bone grafts and biomaterials used as bone graft substitutes
    Ouhayoun, JP
    PROCEEDINGS OF THE 2ND EUROPEAN WORKSHOP ON PERIODONTOLOGY: CHEMICALS IN PERIODONTICS, 1997, : 313 - 358
  • [45] Porous calcium aluminate ceramics for bone-graft applications
    Kalita, SJ
    Bose, S
    Bandyopadhyay, A
    Hosick, HL
    JOURNAL OF MATERIALS RESEARCH, 2002, 17 (12) : 3042 - 3049
  • [46] Histological evaluation of bone response to bioactive ceramics as graft material in rats
    Krsljak, E
    Danilovic, V
    Teodorovic, N
    ACTA VETERINARIA-BEOGRAD, 2005, 55 (5-6): : 461 - 470
  • [47] Porous calcium aluminate ceramics for bone-graft applications
    S. J. Kalita
    S. Bose
    A. Bandyopadhyay
    H. L. Hosick
    Journal of Materials Research, 2002, 17 : 3042 - 3049
  • [48] CORALLINE HYDROXYAPATITE BONE-GRAFT SUBSTITUTES - PRELIMINARY-REPORT OF RADIOGRAPHIC EVALUATION
    SARTORIS, DJ
    GERSHUNI, DH
    AKESON, WH
    HOLMES, RE
    RESNICK, D
    RADIOLOGY, 1986, 159 (01) : 133 - 137
  • [49] BIOTECHNOLOGY AND BONE-GRAFT SUBSTITUTES
    KENLEY, RA
    YIM, K
    ABRAMS, J
    RON, E
    TUREK, T
    MARDEN, LJ
    HOLLINGER, JO
    PHARMACEUTICAL RESEARCH, 1993, 10 (10) : 1393 - 1401
  • [50] Nonallograft osteoconductive bone graft substitutes
    Bucholz, RW
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (395) : 44 - 52