Assessment of E. coli Attenuation during Infiltration of Treated Wastewater: A Pathway to Future Managed Aquifer Recharge

被引:18
|
作者
Donn, Mike [1 ]
Reed, Debbie [2 ]
Vanderzalm, Joanne [3 ]
Page, Declan [3 ]
机构
[1] CSIRO, Land & Water, Private Bag 5, Perth, WA 6913, Australia
[2] Water Corp, Osborne Pk Delivery Ctr, Locked Mail Bag 2,Osborne Pk, Perth, WA 6916, Australia
[3] CSIRO, Land & Water, Locked Bag 2, Adelaide, SA 5064, Australia
关键词
E; coli; managed aquifer recharge; infiltration ponds; treated wastewater; SURVIVAL; RELEASE; STORAGE;
D O I
10.3390/w12010173
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Treated wastewater (TWW) infiltration into non-potable aquifers has been used for decades in Western Australia for disposal and reuse. These wastewater treatment plants (WWTPs) are mostly pond systems, infiltrating secondary TWW with some activated sludge. There is no disinfection of TWW pre-infiltration. This study gave an opportunity to study the fate of Escherichia coli (E. coli) in aquifers, using compliance monitoring data (2006-2016) and is relevant if water reuse is to be implemented at these sites in the future. Microbiological water quality data (E. coli) were evaluated using an advanced statistical method able to incorporate the highly censored data at full scale operational infiltration sites. Subsurface E. coli removal from TWW was observed at all 17 infiltration sites investigated. Most sites (14) had less than six detections of E. coli in groundwater (58-100% non-detects; 7-117 samples/bore), thus the statistical method could not be applied. The observations could be used to infer between 1 to >3 log(10) removal for E. coli. The remaining three sites had sufficient detections for probabilistic modelling analysis, the median removal efficiency for E. coli was quantified as 96% to greater than 99%, confirming at least 1 log(10) removal with potential for several log(10) removal. Reductions could not be explained through dilution with the native groundwater alone as there was a high proportion of TWW in observation bores. The observed reductions are likely the result of bacteria retention and inactivation in the aquifer. The magnitude of microbiological water quality improvement highlights the sustainable and reliable use of the aquifer to improve water quality to levels appropriate for low- and medium-risk non-potable uses without using engineered disinfection methods.
引用
收藏
页数:15
相关论文
共 45 条
  • [21] Managed aquifer recharge: study of undisturbed soil column tests on the infiltration and treatment capacity using effluent of wastewater stabilization pond
    Coutinho, Jaqueline Vigolo
    Almeida, Cristiano das Neves
    da Silva, Eduardo Bernardo
    Stefan, Catalin
    Athayde Junior, Gilson Barbosa
    Moreira Gadelha, Carmem Lucia
    Walter, Florian
    RBRH-REVISTA BRASILEIRA DE RECURSOS HIDRICOS, 2018, 23
  • [22] Reduced removal of bacteriophage MS2 in during basin infiltration managed aquifer recharge as basin sand is exposed to infiltration water
    Mayotte, Jean-Marc
    Holting, Lisanne
    Bishop, Kevin
    HYDROLOGICAL PROCESSES, 2017, 31 (09) : 1690 - 1701
  • [23] Redox processes influencing arsenic mobilization and attenuation at mineral-water interfaces during managed aquifer recharge
    Neil, Chelsea W.
    Jun, Young-Shin
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [24] Quality assessment of treated tannery wastewater with special emphasis on pathogenic E. coli detection through serotyping
    Tuhina Verma
    Pramod W. Ramteke
    Satyendra Kumar Garg
    Environmental Monitoring and Assessment, 2008, 145 : 243 - 249
  • [25] Use of treated wastewater for managed aquifer recharge in highly populated urban centers: a case study in Addis Ababa, Ethiopia
    Abiye, Tamiru Alemayehu
    Sulieman, Hameed
    Ayalew, Michael
    ENVIRONMENTAL GEOLOGY, 2009, 58 (01): : 55 - 59
  • [26] Rapid nutrient load reduction during infiltration of managed aquifer recharge in an agricultural groundwater basin: Pajaro Valley, California
    Schmidt, C. M.
    Fisher, A. T.
    Racz, A.
    Wheat, C. G.
    Los Huertos, M.
    Lockwood, B.
    HYDROLOGICAL PROCESSES, 2012, 26 (15) : 2235 - 2247
  • [27] Risk assessment for the prevention of managed aquifer recharge (MAR) facility failure during the operation and the expansion phases
    Sitek, Slawomir
    Janik, Krzysztof
    Dabrowska, Dominika
    Rozkowski, Jacek
    Wojtal, Grzegorz
    Mukawa, Jakub
    Witkowski, Andrzej Jaroslaw
    Jakobczyk-Karpierz, Sabina
    JOURNAL OF HYDROLOGY, 2023, 621
  • [28] Environmental risk assessment of groundwater quality and treated wastewater reuse on aquifer recharge: a case study in Korba, Tunisia
    Etteieb, Selma
    Kawachi, Atsuchi
    Elayni, Foued
    Han, Junkyu
    Tarhouni, Jamila
    Isoda, Hiroko
    DESALINATION AND WATER TREATMENT, 2014, 52 (10-12) : 2032 - 2038
  • [29] Model-Based Analysis of Reactive Transport Processes Governing Fluoride and Phosphate Release and Attenuation during Managed Aquifer Recharge
    Schafer, David
    Sun, Jing
    Jamieson, James
    Siade, Adam J.
    Atteia, Olivier
    Prommer, Henning
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2020, 54 (05) : 2800 - 2811
  • [30] Footprints of total coliforms, faecal coliforms and E. coli in a wastewater treatment plant and the probabilistic assessment and reduction of E. coli infection risks
    Chen, Sisi
    Chen, Jiangfeng
    Wang, Xiankai
    Li, Ji
    Dong, Bin
    Xu, Zuxin
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 900