Measurement of dose perturbation around shielded ovoids in high-dose-rate brachytherapy

被引:9
|
作者
Hira, Mukhraj [1 ]
Podgorsak, Matthew B. [1 ]
Jaggernauth, Wainwright [1 ]
Malhotra, Harish K. [1 ]
机构
[1] Roswell Pk Canc Inst, Dept Radiat Med, Buffalo, NY 14623 USA
关键词
High-dose-rate brachytherapy; Shielded Fletcher-Suit-Delclos applicator; MONTE-CARLO CALCULATIONS; FLETCHER-SUIT-DELCLOS; RADIOCHROMIC FILM; DOSIMETRY; RECOMMENDATIONS; DISTRIBUTIONS; APPLICATORS; BLADDER; RECTUM;
D O I
10.1016/j.brachy.2010.08.008
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: To analyze the effect of tungsten shields present in a Fletcher-Suit-Delclos ovoid by comparing the dose distribution computed by a treatment planning system (TPS) to the delivered dose distribution measured by radiochromic film dosimetry. METHODS AND MATERIALS: Gafchromic/EBT films were carefully wrapped around the caps (diameter 20-25 mm) of shielded as well as unshielded ovoids, including their anterior and posterior ends. The ovoids were irradiated to a dose of 300 cGy using a high dose rate remote afterloading unit. The films were scanned using Vidar VXR-16 Scanner. The dose distribution in the planes above, below, and on the sides of the ovoid were compared with the dose distribution computed by TPS, which does not account for the presence of shields. RESULTS: The dose distributions obtained about the unshielded ovoid from film dosimetry was in order of what is computed by TPS (90% measurements +/- 5%, maximum 8%). The dose reduction in the anterior part of the shielded ovoid affects maximally the dose to the bladder where a reduction up to 20% was noted. The reduction of dose in the posterior part of the ovoid, which is designed to shield rectum was as high as 23%. Where the shields are not present, insignificant difference in the measured and computed dose values was noticed. CONCLUSIONS: The TPS may substantially overestimate the dose to the bladder and rectum, including regions that lie in the shadow of the solid angle subtended by the shields if it does not account for the presence of tungsten shields. (C) 2011 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:232 / 241
页数:10
相关论文
共 50 条
  • [1] HIGH-DOSE-RATE BRACHYTHERAPY
    SPEISER, BL
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 27 : 116 - 116
  • [2] High-dose-rate brachytherapy and pulsed brachytherapy
    Mazeron, JJ
    EUROCANCER 2002, 2002, : 57 - 58
  • [3] Can Stereotactic Body Radiotherapy Mimic the Dose Distribution of High-Dose-Rate Tandem and Ovoids/ring Brachytherapy?
    Park, S.
    Scanderbeg, D.
    Demanes, J.
    Kamrava, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 313 - 313
  • [4] Characterization of Dose Distributions in High-Dose-Rate Surface Brachytherapy
    Buzurovic, I.
    Hansen, J.
    Bhagwat, M.
    O'Farrell, D.
    Damato, A.
    Friesen, S.
    Devlin, P.
    Cormack, R.
    MEDICAL PHYSICS, 2015, 42 (06) : 3369 - 3370
  • [5] Dose perturbation due to catheter materials in high-dose-rate interstitial 192Ir brachytherapy
    Gaudreault, Mathieu
    Reniers, Brigitte
    Landry, Guillaume
    Verhaegen, Frank
    Beaulieu, Luc
    BRACHYTHERAPY, 2014, 13 (06) : 627 - 631
  • [6] Modern development of high-dose-rate brachytherapy
    Itami, Jun
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2020, 50 (05) : 490 - 501
  • [7] VERIFICATION OF HIGH-DOSE-RATE BRACHYTHERAPY PLANS
    MOWER, HW
    LO, TC
    GIRSHOVICH, L
    LAWSON, BJ
    COSTEY, GE
    RADIOLOGY, 1992, 185 : 129 - 130
  • [8] Low-dose-rate brachytherapy is superior to high-dose-rate brachytherapy for bladder cancer
    Pos, FJ
    Horenblas, S
    Lebesque, J
    Moonen, L
    Schneider, C
    Sminia, P
    Bartelink, H
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (03): : 696 - 705
  • [9] A microDiamondfor determination of absorbed dose around high-dose-rate 192Ir brachytherapy sources
    Kaveckyte, V.
    Malusek, A.
    Benmaklouf, H.
    Carlsson, G. Alm
    Tedgren, A. Carlsson
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S407 - S407
  • [10] PATIENT-SPECIFIC MONTE CARLO DOSE CALCULATIONS FOR HIGH-DOSE-RATE ENDORECTAL BRACHYTHERAPY WITH SHIELDED INTRACAVITARY APPLICATOR
    Poon, Emily
    Williamson, Jeffrey F.
    Vuong, Te
    Verhaegen, Frank
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (04): : 1259 - 1266